34-035-22077

Well Details

Well ID: 34-035-22077
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DUCK CREEK ENERGY INC
Well Pad ID:
Farm/Lease Name: BETA DRIVE UNIT
License Status: Final Restoration
License Date: 2008-10-06
Spud Date: 2008-10-13
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-10-26
Well Total Depth: 3630.00 ft
Configuration: Directional
Latitude: 41.540000
Longitude: -81.440000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-10-06 Proposed Formations:ORISKANY/CLINTON, Issued Date:10/6/2008, Expired Date:10/6/2009 6:00:00 AM, Drilling unit acres:23.58, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-10-26 PLUGGED BACK TO VERTICALLY DRILL FROM SURFACE LOCATION
Correction to Well 2009-06-05 CHANGE IN TARGET INFORMATION AS A RESULT OF "AS DRILLED SURVEY": F00TAGE= 1225'NL & 290'EL OF LOT 44, TRACT 1/ X= 2,287,555 AND Y= 685,385.
Construction Permit Expires 2009-10-06 PLUGGED BACK TO VERTICALLY DRILL FROM SURFACE LOCATION
Completion Report Received 2009-12-08 PLUGGED BACK TO VERTICALLY DRILL FROM SURFACE LOCATION
Plugged Back 2010-02-12 PLUGGED BACK TO VERTICALLY DRILL FROM SURFACE LOCATION
Record Last Modified 2015-09-24 PLUGGED BACK TO VERTICALLY DRILL FROM SURFACE LOCATION

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-06-24 3309 3330 44
3397 3469 80
3309 3330 44
3397 3469 80

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 103642 Gal 80000 500 GALLONS HCL ACID..TREATED @ 40 BPM

For data sources see[4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 DUCK CREEK ENERGY INC Brine 415 269
2011 DUCK CREEK ENERGY INC Brine 0 365
2012 DUCK CREEK ENERGY INC Brine 32 366
2015 DUCK CREEK ENERGY INC Brine 0 365
2016 DUCK CREEK ENERGY INC Brine 0 365
2017 DUCK CREEK ENERGY INC Brine 0 365
2018 DUCK CREEK ENERGY INC Brine 0 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1183549376 2018-5-30 0:00: UP No Violations 1.00
-1211391297 2010-3-17 0:00: DD No Violations
-1604024954 2008-11-18 0:00 DD No Violations
-164968552 2009-10-26 0:00 PL No Violations
-1750381639 2008-11-12 0:00 DD No Violations
-1999598346 2017-9-5 0:00:0 UP No Violations 0.50
-2104251918 2009-4-27 0:00: DD No Violations
-733111531 2017-3-13 0:00: UP No Violations 0.50
-778669014 2009-1-5 0:00:0 DD No Violations
-845251795 2010-3-16 0:00: DD No Violations
-937827070 2008-10-29 0:00 DD No Violations
0055316789 2009-11-30 Production Wells No Violations no violation
0164968552 2009-10-26 Preliminary Restoration No Violations crew working on tank battery reworking stone work .fencing around well location.
0226665281 2018-05-30 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery in separate enclosures, both located within the asphalt-paved parking area of a multi-tenant business center. The enclosure gates were locked and secure. The load-line valves were secure. I had noted previously that the production data was missing, but subsequently found that the data was being reported under this API number (34-035-2-2077-01) and not API Number 34-035-2-2077.
0733111531 2017-03-13 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection. At the time of this inspection I observed the following: a wellhead with plunger lift system and associated tank battery in separate enclosures which were locked and secure. The valves and connections at both the well and battery were secure and free from signs of leakage. Process safety equipment was present. ID signage was present and accurate. The areas surrounding the well and battery were comprised of asphalt parking and drive areas for the hotel facility located on the parcel. I walked the surrounding areas and found no signs of impacts or degradation. Access to the well and battery was afforded by shared-use, asphalt-paved driveway which was in good condition.
0778669014 2009-01-05 Drill / Deepen / Reopen No Violations company working on tank battery
0845251795 2010-03-16 Drill / Deepen / Reopen No Violations Rig moving on site this day. Pits are going to be north of the rig between rig and building. There is no room to have pits to the south of the rig. Pits are being dug on the same location as they were the first time. Operator trucked asphalt and solidified pit material from construction of the pits offsite. Requested that the operator build a berm on the south side of the pit. Operator has a reinforced liner on site for the pit. Permit sign is posted. Permit is on site. Wire fence is up around site. Safety signs are up. Well is 101 from the building. Bottom and sides of the pit were shale and cuttings, no water noted.
0937827070 2008-10-29 Drill / Deepen / Reopen No Violations site inspection
0938535206 2015-02-20 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead mechanical plunger lift and tank battery enclosures are locked and secure. System fittings and connections are secure and free from signs of leakage or problems. Load-outs are plugged, locked and secure. ID signage is present and accurate. Access to the unit is shared with the adjacent apartment community. At the time of this inspection, there is 12 to 14 inches of snow cover which obscures some surficial features.
1157241582 2013-01-08 UrbanProduction Wells No Violations The producing unit is comprised of a two-tank battery (2 140-barrel, 1 20-barrel) with mechanical separator. The tank battery is enclosed in an 8-foot board-on-board enclosure. The well is currently shut-in. The secondary containment is adequate. Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination. There is has been no production reports filed since this well was completed in 2010. I contacted Larry Gibler of Duck Creek regarding the missing data. I also contacted Vicky McKinney (ODNR-Columbus) and determined that the missing production data had been misdirected. The data is being moved.
1183549376 2018-05-30 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery in separate enclosures, both located within the asphalt-paved parking area of a multi-tenant business center. The enclosure gates were locked and secure. The load-line valves were secure. I had noted previously that the production data was missing, but subsequently found that the data was being reported under API number 34-035-2-2077-01 and not API Number 34-035-2-2077.
1211391297 2010-03-17 Drill / Deepen / Reopen No Violations cementing 4.5 casing in directional well that was plugged back and drilled straight.
1230563455 2008-10-14 Drill / Deepen / Reopen No Violations waiting on cement conductor set 96
1268058427 2010-03-05 Drill / Deepen / Reopen No Violations No rig on site. Well location is fenced with temporary chain link fence. Permit sign is up. Drilling location is in a parking lot, no drainage noted.
1268756316 2010-03-16 Drill / Deepen / Reopen No Violations Drill depth 3257, drilling on fluid. Check site with gas meter H2S, zero LEL, zero. Checked at the discharge zero LEL and H2S. Safety fence is up. Pit is in good repair. Safety signs are up. Permit is posted. Fire extinguisher is on the boom. Drill pipe is on site. Eric Poulson is the driller this day. Eric stated he noted an odor in the Newburg, odor is gone at this time.
1275487988 2010-03-15 Drill / Deepen / Reopen No Violations drilling at 3190 no gas drilling on fluid. No violation.
1326465653 2012-01-11 UrbanPreliminary Restoration No Violations On 01/11/2012, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
1604024954 2008-11-18 Drill / Deepen / Reopen No Violations still swabbing
1750381639 2008-11-12 Drill / Deepen / Reopen No Violations well being swabbed
1999598346 2017-09-05 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery in separate enclosures, both located within the asphalt-paved parking area of a multi-tenant business center. The enclosure gates were locked and secure. The load-line valves were secure. I noted that production data was missing for this well and I submitted and inquiry to the well owner about the missing production data.
2104251918 2009-04-27 Drill / Deepen / Reopen No Violations no violation
226665281 2018-5-30 0:00: UP No Violations
55316789 2009-11-30 0:00 PW No Violations
938535206 2015-2-20 0:00: UP No Violations 0.50

For data sources see[7]