Well ID: 34-035-22105 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.3,"lon":-81.66,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: J WELL SERVICE INC | |
Well Pad ID: | |
Farm/Lease Name: HORONZY | |
License Status: Producing | |
License Date: 2009-02-23 | |
Spud Date: 2009-04-04 | |
Spud Drilling Contractor: WILDCAT DRILLING | |
Final Drill Date: 2009-04-08 | |
Well Total Depth: 3745.00 ft | |
Configuration: Vertical | |
Latitude: 41.300000 | |
Longitude: -81.660000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2009-02-23 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:2/23/2009, Expired Date:2/23/2010 6:00:00 AM, Drilling unit acres:21.52, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2009-04-08 | |
Completion Report Received | 2009-08-10 | |
Construction Permit Expires | 2010-02-23 | |
Change of Owner | 2018-01-09 | Operator changed from 2456, OHIO VALLEY ENERGY SYSTEM CORP to 8738, J WELL SERVICE INC |
Record Last Modified | 2018-01-09 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-10-15 | 3478 | 3534 | 45 |
3478 | 3534 | 45 | |
3478 | 3534 | 45 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 2147 Bbl | 60000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | OHIO VALLEY ENERGY SYSTEMS COR | 8285.00 | 169.00 | 351 |
2011 | OHIO VALLEY ENERGY SYSTEMS COR | 4521.00 | 161.00 | 365 |
2012 | OHIO VALLEY ENERGY SYSTEMS COR | 2650.00 | 77.00 | 366 |
2013 | OHIO VALLEY ENERGY SYSTEMS COR | 1395.00 | 46.00 | 365 |
2014 | OHIO VALLEY ENERGY SYSTEMS COR | 726.00 | 0.00 | 365 |
2015 | OHIO VALLEY ENERGY SYSTEMS COR | 808.00 | 95.00 | 365 |
2016 | OHIO VALLEY ENERGY SYSTEMS COR | 436.00 | 0.00 | 365 |
2017 | OHIO VALLEY ENERGY SYSTEMS COR | 331.00 | 72.00 | 216 |
2018 | OHIO VALLEY ENERGY SYSTEMS COR | 1224.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 335 | 351 |
2011 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 346 | 365 |
2012 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 285 | 366 |
2013 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 210 | 365 |
2014 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 273 | 365 |
2015 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 106 | 365 |
2016 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 0 | 365 |
2017 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 74 | 216 |
2018 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1293135249 | 2018-1-3 0:00:0 | UP | No Violations | 0.50 |
-1672350528 | 2009-4-16 0:00: | DD | No Violations | |
-1959245509 | 2017-6-30 0:00: | UP | No Violations | 1.00 |
-758263057 | 2015-3-30 0:00: | UP | No Violations | 0.50 |
-980406522 | 2014-4-16 0:00: | UP | No Violations | |
0758263057 | 2015-03-30 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. The wellhead and battery are located behind the single-family residence at the referenced address. Access to the well and battery are from the shared driveway and then continue west on the unpaved access road to the unit. The wellhead is comprised of a pump jack system. Fittings and connections are secure. The tank battery is comprised of 1 100-barrel steel production tank, 1 50-barrel poly brine tank and separator unit in a separate board-on-board enclosure. Elements of the system are in general good repair. Fittings and connections are secure and free from signs of leakage at the time of this inspection. The load-outs are plugged and secure. ID signage and secondary containment are present. Areas surrounding the wellhead and battery are reasonably well drained and free from signs of adverse impact from the on-going production activity associated with this well. |
0980406522 | 2014-04-16 | UrbanProduction Wells | No Violations | The producing unit is comprised of a pump jack and aboveground storage tank (AST) battery in separate board-on-board enclosures. The enclosures are locked. Signage and ID is present and in good condition. There is secondary containment at the wellhead and battery. The well is producing with no signs of leakage or problems. The battery is comprised of 1 steel 100-barrel production tank and 1 poly 50-barrel brine tank, separator units and Dominion metering run. Process safety equipment is present. The dike is free of oil. The loadouts are bullplugged. The lease road and surrounding areas are well maintained and runoff appears to be well managed. |
1243869024 | 2009-04-02 | Drill / Deepen / Reopen | No Violations | Company making location. Landowner thinks its off location (stake was moved).Inspected wellsite with GPS (stake was not moved) The well location is correct. |
1254247935 | 2009-08-24 | Preliminary Restoration | No Violations | No violation of HB278 |
1264011184 | 2010-01-11 | Production Wells | No Violations | No violation |
1293135249 | 2018-01-03 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located in separate board on board enclosures in a low-lying and wooded area. I found the wellhead and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems. There were several inches of snow in the area. |
1672350528 | 2009-04-16 | Drill / Deepen / Reopen | No Violations | pits closed |
1959245509 | 2017-06-30 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located in a clearing in a wooded portion of a residential parcel. At the time of this inspection, I observed the following: the wellhead and battery enclosures were locked and secure. Fittings and connections at the wellhead and battery were secure and free from leakage, or other observable problems. The load-line valves were closed, plugged and locked. The secondary containment was intact and free from signs of spills or leaks. The dedicated portion of the lease road was grassy in places but passable and well drained. I walked the areas surrounding the well and battery and found the natural greenscape to be free from signs of impacts or problems. |
2016908144 | 2015-07-28 | UrbanProduction Wells | No Violations | I inspected this well location pursuant to a complaint (#5087) regarding loud noise reported to be coming from the well location. At the time of my inspection, the pump jack is idle. I previously had notified Ohio Valley Energy regarding the noise complaint. Fittings and connections at the wellhead and the battery are secure. I did not observe any unusual noises. I will follow up again with the well owner to confirm that the source of the noise has been identified and resolved if associated with the well operation. |
For data sources see[9]