{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.33,"lon":-81.7,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR | |
Well Pad ID: | |
Farm/Lease Name: DELLAVALLE | |
License Status: Producing | |
License Date: 2010-02-17 | |
Spud Date: 2010-03-31 | |
Spud Drilling Contractor: WILDCAT DRILLING | |
Final Drill Date: 2010-04-07 | |
Well Total Depth: 3646.00 ft | |
Configuration: Vertical | |
Latitude: 41.330000 | |
Longitude: -81.700000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2010-02-17 | Proposed Formations:OHIO SHALE/CLINTON, Issued Date:2/17/2010, Expired Date:2/17/2011 6:00:00 AM, Drilling unit acres:21.8236, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2010-04-07 | |
Correction to Well | 2010-07-16 | UNIT INCREASED TO 28.5466 ACRES. |
Completion Report Received | 2010-09-22 | |
Construction Permit Expires | 2011-02-17 | |
Change of Owner | 2018-04-13 | Operator changed from 1249, CUTTER OIL CO to 2456, OHIO VALLEY ENERGY SYSTEM CORP |
Record Last Modified | 2018-04-13 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-11-08 | 3393 | 3426 | 42 |
3393 | 3426 | 42 | |
3393 | 3426 | 42 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 200 Mscf | 60000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | CUTTER OIL COMPANY | 11850.00 | 6145.00 | 233 |
2011 | CUTTER OIL COMPANY | 21507.00 | 5359.00 | 365 |
2012 | CUTTER OIL COMPANY | 21536.00 | 4136.00 | 366 |
2013 | CUTTER OIL COMPANY | 15298.00 | 2528.00 | 365 |
2014 | CUTTER OIL COMPANY | 10123.00 | 1651.00 | 365 |
2015 | CUTTER OIL COMPANY | 7470.00 | 1120.00 | 365 |
2016 | CUTTER OIL COMPANY | 6016.00 | 808.00 | 365 |
2017 | CUTTER OIL COMPANY | 5970.00 | 872.00 | 365 |
2018 | OHIO VALLEY ENERGY SYSTEMS COR | 2508.00 | 444.00 | 214 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | CUTTER OIL COMPANY | Brine | 2413 | 233 |
2011 | CUTTER OIL COMPANY | Brine | 366 | 365 |
2012 | CUTTER OIL COMPANY | Brine | 203 | 366 |
2013 | CUTTER OIL COMPANY | Brine | 30 | 365 |
2014 | CUTTER OIL COMPANY | Brine | 0 | 365 |
2015 | CUTTER OIL COMPANY | Brine | 108 | 365 |
2016 | CUTTER OIL COMPANY | Brine | 147 | 365 |
2017 | CUTTER OIL COMPANY | Brine | 72 | 365 |
2018 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 24 | 214 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1194225606 | 2010-4-1 0:00:0 | DD | No Violations | |
-1612936335 | 2018-3-22 0:00: | UP | No Violations | 0.50 |
-1915555672 | 2020-1-27 0:00: | UP | No Violations | |
-1936200195 | 2015-6-24 0:00: | UP | No Violations | |
-2011552950 | 2018-4-19 0:00: | UP | No Violations | 1.00 |
-2061611207 | 2010-3-16 0:00: | DD | No Violations | |
-330956704 | 2011-9-7 0:00:0 | UP | No Violations | |
-425474696 | 2011-12-8 0:00: | UP | No Violations | 1.00 |
-515847396 | 2015-6-22 0:00: | UP | No Violations | |
-667100887 | 2019-5-6 0:00:0 | PW | No Violations | |
-735245865 | 2014-1-13 0:00: | UL | No Violations | |
-865912053 | 2014-7-10 0:00: | UP | No Violations | |
0180273610 | 2010-04-01 | Drill / Deepen / Reopen | No Violations | cemented conductor casing. |
0272615309 | 2010-02-16 | Administrative Inspection | No Violations | Held on site meeting to discuss the site construction and permit conditions. |
0330956704 | 2011-09-07 | UrbanProduction Wells | No Violations | Urban Producing well , status check. No violations found. Well is in compliance. |
0373122312 | 2010-04-02 | Drill / Deepen / Reopen | No Violations | tested BOP PASSED. |
0425474696 | 2011-12-08 | UrbanProduction Wells | No Violations | On 12/08/2012, DNR Inspector Richard Skidmore completed an urban production well inspection status check for DNR Inpsector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed. |
0515847396 | 2015-06-22 | UrbanProduction Wells | No Violations | I met with Mayor Bob Stefanik at the well location in response to a complaint registered from a neighbor regarding observed oil sheen downslope from the referenced well. Reportedly, there has been re-current and chronic issues with drainage on the referenced property. At the time of this visit, I observe some areas where surface water is ponding in the grass. Some of these areas appear to be draining poorly. Reportedly, at the time that the well was completed, the operator (Cutter Oil) installed a drainage connection between the gravel drive and a drainage catch basin 80 feet east of the edge of the driveway, hereinafter referred to as CB#1. That catch basin is believed to connect to a 2nd catch basin located 110 feet further east near the eastern property boundary, hereinafter referred to as CB#2. CB#2 drains to the west side Foxwood Drive tree lawn, via an 8-inch PVC pipe which travels east and terminates as an open pipe under a shrub. The tree lawn area around the terminus is saturated with effluent storm water. Drainage from this area is to the south towards a 3rd catch basing (CB#3). Surface water is also seen to be traveling over the sidewalk and into Foxwood Drive. The landowners (Dellavalle) report that there have been historical problems with drainage at the property and attribute some of this to the presence of the well.
A neighbor reported seeing oil sheen in the water ponded along Foxwood Dr. Sheen was also noted in the area of CB#1 and near the wellhead. At the time of this inspection, I observed sheen on surface water at the following locations: on ponded water on the east side of the wellhead, on ponded surface water near CB#1, and on ponded surface water along Foxwood Dr. Upon close inspection, I noted the sheen to break up and fracture on physical contact. There is no petroleum odor. These observations suggest that the sheen is related to iron bacterial activity and not associated with crude oil or other petroleum source.An inspection of the well |
0667100887 | 2019-05-06 | Production Wells | No Violations | I conducted an inspection of the well and found no violation at well or common tank battery with the Dellavalle 2D.
The following maintenance issue needs to be corrected. Gaps between the top of the dike and bottom of the board on broad fencing around the dike. Fluid has collected within the Dike area needs to be removed and disposed of properly. Charcoal filter needs replaced due to bottom rusted out. I contacted Rick Little and he stated the fluid will be pumped out and disposed of and the charcoal filter, fencing issues it will be put on the repair schedule. |
0735245865 | 2014-01-13 | UrbanPreliminary Restoration | No Violations | The unit is in production. The pits have been filled and restored. The area is appropriately landscaped and enclosures are present and locked. No further preliminary restoration work is needed. |
0798077849 | 2010-04-05 | Drill / Deepen / Reopen | No Violations | drilling on air switching to fluid top lime approx 1800. |
0865912053 | 2014-07-10 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activities. The wellhead which is currently fitted with a pump jack system is in operation. Production reports are current. System operation at the above-ground storage tank (AST) battery appears normal. Safety apparatus are present and I observed no signs of leaks, spills, or problems. |
0913736460 | 2012-09-14 | UrbanProduction Wells | No Violations | Well was inspected on this date for training purposes. Training co-coordinator for the division of oil and gas accompanied me. This is a vertical well and shares a tank battery with the Dellavalle 2 D well. Pressure at the annulus was 150 PSI. The tank battery is shared with Dellavalle 2D and each well has a separator, 2 (Two) 100 Barrel tanks and 1 50 barrel brine tank. There is one sales line for both wells. No violations were found. Well is in compliance. |
0965629199 | 2010-08-03 | Production Wells | No Violations | Responded to site because received phone call from the fire department that a resident in area had smelled gas from tank battery. Fire department responded to site to checked for gas with their meter NO detectable gas reading.
Checked site found well had been shut in and not pumping , because EOG not taking gas? Case #10-008 |
1176734851 | 2010-04-01 | Drill / Deepen / Reopen | No Violations | cementing surface casing 85/8 |
1194225606 | 2010-04-01 | Drill / Deepen / Reopen | No Violations | cementing conductor casing Good returns to surface. |
1223275673 | 2018-02-08 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. At the time of this inspection, fittings and connections at the wellhead pump jack and battery were secure and free from leakage or problems. The individual enclosures were locked and secure. Production reports were current. Proper bonding and insurance was in place. The surrounding areas were covered in several inches of fresh snow cover. |
1338910882 | 2011-08-29 | UrbanProduction Wells | No Violations | Case Number 11-003. Complaint of strong gas odor .
I inspected this site and found the well and site in compliance. No violation noted. Note : When well is pumping fluids into the oil storage tanks the fumes are going through the charcoal filter and also through the low pressure valve on the hatch lid, which is unfiltered. |
1437656373 | 2015-07-22 | UrbanProduction Wells | No Violations | I met with Northeast Region Supervior Tom Hill at this location as part of on-going investigation of complaint relating reported sheen along Foxwood Dr. At the time of this inspection, the areas of standing water in the grass along the west side of Foxwood Dr. are wet but with less stagnant water. We observed some reddish iron staining on the sidewalk in areas where the sheen and baterial slime effluent have been previously observed. We performed Quantab analysis at the catch basin on the Dellavale property and at the secondary containment drains at the Dellavalle 1 and 2, and the tank battery. Chloride readings ranged from 200 to 450 mg/L at the wellhead area and the storm inlet, respectively. We did not observe any signs of stressed vegeatation in the areas where sheen has been reported. |
1497050020 | 2013-10-28 | UrbanProduction Wells | No Violations | The producing unit consists of a wellhead with pump jack and above-ground storage tank (AST) battery. The battery is comprised of 4 140-barrel steel production tanks, 2 50-barrel brine tanks and 2 separator units with Dominion metering run. The battery is shared with the #2181 unit. Both the wellhead and battery are enclosed in separate board-on-board fences. The gates and load-outs are locked. ID placard and secondary containment are good. Process safety gear (spark arrestor, low-pressure relief valve, carbon filter) is present. No problems noted. |
1612936335 | 2018-03-22 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located on a suburban parcel . At the time of my inspection, I found the following: wellhead with pump jack system and associated battery in separate board-on-board enclosures. The enclosure gates were locked and secure. The fittings and connections at the wellhead and battery were secure and free from problems. The tank lids were closed and secure. The interior of the battery, including secondary containment was free from free oil, staining, or other indications of spills, leaks, or problems. The battery is shared with the Dellavalle #2D, located nearby. The electrical panels and load line valves were locked and secure. I walked and inspected the areas surrounding the well and battery and found no indications of impacts or problems relating to the on-going production activity. The shared-use access road was snow-covered by accessible. |
1643302669 | 2015-05-07 | UrbanProduction Wells | Violations Noted | I was on site to conduct a status check of this well with DOGRM Inspector - John Fleming and District Manager - Rick Anderson. The wellhead is equipped with a pumpjack and the valves on the wellhead were open. Identification signs are present on the tank battery and wellhead fences, but are not urban rule compliant. The belt guard for the pumpjack was on the ground next to it. There was an open 5 gallon bucket full of oil next to the wellhead. The tank battery consisted of 4-140 BBL production tanks, 2 mechanical separators, and 2-1500 gallon poly brine tanks. The production tank sealable hatches are not secured properly. The vent stacks are equipped with pressure relief valves, but no lightning arrestors. There is a charcoal filter. The tank pick-up line valves have flat plugs but are not locked. The crossover line between the production tanks is leaking. The brine tank is seeping at the valve connection and the bleeder line has oil staining under it. The pick-up lines have oil staining at the base and one is leaking, and none are locked. The well and tank battery were fenced with 8-foot board-on-board fencing, and the man doors were locked. The lease road is stable and drivable. The following needs completed by:
1) Clean-up all spilled oil/brine in tank battery and remove any containers containing fluid (6-16-15) 2) Insert plugs/or add locks into the tank valves and pick-up lines (6-16-15) 3) Install lightning arrestors on vent stacks (6-16-15) 4) Add additional identification sign information as required by 1501:9-9- |
1725263536 | 2010-09-02 | Urban Drill / Deepen / Reopen | No Violations | Cutter crew working on leveling site getting ready For Rig. |
180273610 | 2010-4-1 0:00:0 | DD | No Violations | |
1936200195 | 2015-06-24 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous Compliance Notice. Load lines are now lock-protected. Tank lids are sealed and secure. Electrical boxes are locked and secure. Process safety gear, including spark arrestor is present. Secondary containment at the well and battery are intact. The leaking cross-over leakage and oil staining has been mitigated. Update of signage is in progess. |
1965155472 | 2015-02-10 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The well and battery are located behind the single-family residence at 3331 Wallings Road. Access is shared with the residential driveway The Dallavalle 1 (#2-2146) is co-located with the Dellavalle 2 (#2-2163) and share a common tank battery. The wellhead pump jack and battery are located in separate board-on-board enclosures. The enclosure gates are locked and signage is present. Observable fittings and connections are secure and free from signs of leakage. At the time of this inspection there is 12 to 15 inches of snow cover which limits my ability to inspect the condition of the lease road, interior of the battery containment, and other surficial features. |
2009281940 | 2010-04-07 | Drill / Deepen / Reopen | No Violations | cemented 4.5 casing |
2011552950 | 2018-04-19 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The well had recently changed owner. At the time of this inspection, the new ID signage was in place and in compliance, fittings and connections at the wellhead pump jack and battery were secure and free from leakage or problems. The tank lids were closed and secure. Load-line valves were locked and secure with plugs. The secondary containment The individual enclosures were locked and secure. The secondary containment was intact and free from signs of problems. I walked the areas surrounding the well and battery and found the surrounding areas free from signs of impacts relating to the on-going production. The shared-use access road was in good condition. The well was in active production. |
2027587392 | 2017-04-28 | UrbanProduction Wells | No Violations | I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I noted the following: a wellhead with pump-jack system and associated tank battery in separate board-on-board enclosures located on a residential property. The well is co-located with the #2-2181 well. Fittings and connections at the wellhead were secure. The pump-jack supports were solid. The stuffing box fitting was secure with no leaking or problems. The bridle attachments were secure. Fittings and connections at the battery were secure. The load-line valves were plugged and locked. The tank lids were closed and sealed. The secondary containment had several inches of standing water from recent rainfall. The water was clear and free from any signs of spills, leaks, or other problems. Access to the two wells and associated battery is from a shared-use, gravel-paved access road that enters from Wallings Road and also provides access to a barn and residential structure. I walked the areas surrounding the well and battery systems and observed the natural soils and vegetation to be free from signs of leaks, spills, or other adverse impact from the on-going production activity. |
2061611207 | 2010-03-16 | Drill / Deepen / Reopen | No Violations | No violation company on site grading location top soil to southeast,Silt fencing along the east and south of well location. |
272615309 | 2010-2-16 0:00: | AM | No Violations | |
373122312 | 2010-4-2 0:00:0 | DD | No Violations | |
798077849 | 2010-4-5 0:00:0 | DD | No Violations | |
913736460 | 2012-9-14 0:00: | UP | No Violations | 1.00 |
965629199 | 2010-8-3 0:00:0 | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1643302669 | US-OH-116180 | 2015-06-08 | LOCKS | |
1643302669 | US-OH-116181 | 2015-06-08 | TANKS (a-i) | |
1643302669 | US-OH-116182 | 2015-06-08 | Failure to keep dike or pit free of brine or other wastes |