If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-22147 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.32,"lon":-81.71,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: EOS ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: CALLAS UNIT | |
License Status: Producing | |
License Date: 2010-02-17 | |
Spud Date: 2010-04-20 | |
Spud Drilling Contractor: WILDCAT DRILLING | |
Final Drill Date: 2010-04-24 | |
Well Total Depth: 3676.00 ft | |
Configuration: Vertical | |
Latitude: 41.320000 | |
Longitude: -81.710000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2010-02-17 | Proposed Formations:OHIO SHALE/CLINTON, Issued Date:2/17/2010, Expired Date:2/17/2011 6:00:00 AM, Drilling unit acres:33.7513, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2010-04-24 | |
Completion Report Received | 2010-08-09 | |
Construction Permit Expires | 2011-02-17 | |
Correction to Well | 2012-01-27 | UNIT SIZE INCREASED TO 33.0897 ACRES. |
Change of Owner | 2018-07-31 | Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC |
Record Last Modified | 2018-07-31 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-11-01 | 3416 | 3457 | 59 |
3416 | 3457 | 59 | |
3416 | 3457 | 59 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 89258 Gal | 50000 | 204M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | CUTTER OIL COMPANY | 3048.00 | 5882.00 | 365 |
2011 | CUTTER OIL COMPANY | 39301.00 | 8388.00 | 365 |
2012 | CUTTER OIL COMPANY | 28538.00 | 3334.00 | 366 |
2013 | CUTTER OIL COMPANY | 21236.00 | 2613.00 | 365 |
2014 | CUTTER OIL COMPANY | 14295.00 | 1557.00 | 365 |
2015 | CUTTER OIL COMPANY | 8653.00 | 1076.00 | 365 |
2016 | CUTTER OIL COMPANY | 8787.00 | 930.00 | 365 |
2017 | CUTTER OIL COMPANY | 7220.00 | 902.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | CUTTER OIL COMPANY | Brine | 2360 | 365 |
2011 | CUTTER OIL COMPANY | Brine | 285 | 365 |
2012 | CUTTER OIL COMPANY | Brine | 123 | 366 |
2013 | CUTTER OIL COMPANY | Brine | 130 | 365 |
2014 | CUTTER OIL COMPANY | Brine | 30 | 365 |
2015 | CUTTER OIL COMPANY | Brine | 86 | 365 |
2016 | CUTTER OIL COMPANY | Brine | 81 | 365 |
2017 | CUTTER OIL COMPANY | Brine | 80 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1037568756 | 2019-5-1 0:00:0 | UP | No Violations | |
-1122945619 | 2010-9-22 0:00: | UD | No Violations | |
-1315582849 | 2017-11-8 0:00: | UP | No Violations | 0.50 |
-1498570927 | 2017-4-27 0:00: | UP | No Violations | |
-1573568776 | 2018-10-16 0:00 | UP | No Violations | |
-1958334173 | 2010-4-23 0:00: | DD | No Violations | |
-2022844115 | 2014-2-20 0:00: | UP | No Violations | |
-2099295281 | 2015-5-7 0:00:0 | UP | No Violations | |
-2107413754 | 2014-7-10 0:00: | UP | No Violations | |
-355298951 | 2010-4-22 0:00: | DD | No Violations | |
-703573340 | 2012-11-28 0:00 | UL | No Violations | 1.00 |
-810870509 | 2010-4-21 0:00: | DD | No Violations | |
-883272290 | 2013-10-28 0:00 | UP | No Violations | |
0187449013 | 2013-04-03 | UrbanProduction Wells | No Violations | The producing unit consists of the following elements: a production wellhead and a storage tank battery. The production wellhead is fitted with a pumpjack system and is currently producing. The pumpjack unit is enclosed in an 8-foot board-on-board enclosure which is locked. The tank battery consists of 4 100-barrel steel tanks, 1 100-barrel steel tank, and 2 separator units. The battery is enclosed in a board-on-board enclosure. Safety equipment (carbon filter, spark arrestor, low-pressure relief valve) is present. The secondary containment is present and in good condition. No violations noted. The tank battery is shared with the Callas 6D Unit. |
0232417946 | 2010-02-16 | Administrative Inspection | No Violations | Held on site meeting to discuss the onsite construction and permit conditions. |
0355298951 | 2010-04-22 | Drill / Deepen / Reopen | No Violations | witnessed BOP Testing PASSED. |
0543254216 | 2015-04-02 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. The well and tank battery are located in cleared, but undeveloped parcel in an otherwise residential area, adjacent to the house at the referenced address. Fittings and connections at the wellhead pump jack and battery are secure and free from signs of leakage or problems. Load-outs are secure. Gates are locked. Process safety equipment is present. No problems noted at the time of this inspection. |
0703573340 | 2012-11-28 | UrbanPreliminary Restoration | No Violations | My visit to the well today was for an Urban Preliminary Restoration inspection. First 50 feet of access drive is cement then crushed limestone and brick packed to a depth of six inches. Wellhead is surrounded by a board on board fence and no violations were noted at well. Tank battery is enclosed in board on board fencing with a dike sufficient to hold fluids per 1501:09-9-05 and is secured by chain and locks. This tank battery is shared with the Callis 6D well and has two 140 BBL storage tanks with caps and vents which are closed and secure, there is a charcoal filter unit for the tank unit. There is one 100 BBL brine tank which is shared by both wells. There is one vertical and one horizontal separator. Lost lines are secured by locks and bull plugs. No violations were found or noted and restoration inspection passed. |
0810870509 | 2010-04-21 | Drill / Deepen / Reopen | No Violations | cementing the conductor casing. |
0883272290 | 2013-10-28 | UrbanProduction Wells | No Violations | The unit is producing and no problems noted. No changes since the last inspection. |
0922110022 | 2010-04-24 | Drill / Deepen / Reopen | No Violations | Phone call from company CJ Cutter advising cementing 4.5 casing I was unable to cover gave OK to cement . Note: No gas or loss circulation was encountered while drilling. |
1122945619 | 2010-09-22 | Urban Drill / Deepen / Reopen | No Violations | Drilling on air 1160 Will swtich to fluid at top of lime 1680 |
1315493878 | 2011-09-07 | UrbanProduction Wells | No Violations | Urban well inspection. Well is in compliance. |
1315582849 | 2017-11-08 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and associated battery are located on an otherwise undeveloped parcel, and the battery is shared with the Callas #6D well located on the same parcel. At the time of my inspection, the fittings and connections at the well were secure. The tank lids were closed and secure. The load-line valves were plugged and locked. The secondary containment was intact, with some water from recent rains. There was no signs of leakage (floating oil or sheen) visible. I walked and inspected the areas surrounding the wellhead and battery and found no signs or evidence of impacts or degradation. The access point was gated and locked with signage present. The access road was in good condition. |
1440772727 | 2015-08-24 | UrbanProduction Wells | No Violations | I inspected this producing unit as a follow-up to an earlier inspection in which several safety deficiencies had been noted. Those deficiencies consisted of the following: unsecured tank lids, unlocked load-lines and electrical boxes, incomplete or damaged ID signage, open containment drain, and missing spark arrestors on the production tanks. At the time of this inspection, the noted safety deficiencies have been addressed. The 8.625-inch casing is plumbed to surface with pop-off. The previous inspection had also noted some brine leakage at the poly tank. At the time of this inspection, these issues have been addressed. I have also discussed with the owner the on-going management of surface water runoff adjacent to the wellhead. This area had been previously noted to be forming a natural run-off feature and may possible need managed to prevent erosional soil loss. At the time of this inspection, natural vegetation has become established following a previous high-flow event. The need for management does not appear warranted at this time. |
1491732985 | 2015-01-29 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The wellhead pump jack enclosure is secure. Valves and connections are secure and free from signs of leakage or problems. At the time of my inspection, the area is covered with several inches of snow. The dedicated access road has been plowed and is clear and passable. The tank battery which is shared with the #2-2194 unit is secure. Valves and connections are secure. Load-outs are bull-plugged and locked. I did not observe any problems at the time of this inspection. |
1498570927 | 2017-04-27 | UrbanProduction Wells | No Violations | I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I noted the following: a wellhead with pump-jack system and associated tank battery in separate board-on-board enclosures. The battery is shared with the Callas #6D, located on the same parcel. The enclosure gates were locked and secure. Fittings and connections at the wellhead were secure. The surface casing pressure was being monitored and showed no pressure. The electrical panel box w as locked and secure. Fittings and connections at the battery were secure. The load-line valves were plugged and locked. The tank lids were closed and sealed. The secondary containment drain was secure. There was some standing water in the containment area from recent rainfall. The water was clear with no signs of floating oil or sheen. The gravel-paved access road was level and dry. I did note some landscaping fabric debris in the parking area and I notified CJ Cutter about the need for removal of the debris. The entry gate was locked. I walked the areas surrounding the well and battery systems and observed the natural soils and vegetation to be free from signs of leaks, spills, or other adverse impact from the on-going production activity. |
1573568776 | 2018-10-16 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection and evaluation of current condition following recent change in ownership. At the time of this inspection, I met with EOS Energy Representative Mike Corp and North Royalton Fire Chief Chegan. I noted that the well was in active production. The enclosure gates were locked and secure. The identification was current and accurate. The load-line valves were plugged and locked. Tank lids were closed and sealed. I walked the areas surrounding the well and battery and found no signs of problems or indications of impact. I noted the following maintenance items that required attention: The belt guard on the pump jack motor was not in place. There were discarded 55-gallon drums in the well enclosure, which require removal and disposal. I advised Mike to have these items remedied as soon as possible. I also noted that the gate at the access road was not secure and required proper signage. He indicated that he would have the issues addressed as soon as possible. |
1599765080 | 2010-04-22 | Drill / Deepen / Reopen | No Violations | cementing surface casing 85/8. |
1683790172 | 2018-01-26 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection. Fittings and connections at the well and battery (shared with the Callas 6D) were secure and free from leakage or problems. Load lines were plugged and locked. Tank lids were closed. The secondary containment was intact and free from standing water, or signs of leakage of petroleum fluids. The individual enclosure gates were locked. Bonding and insurance were current. Production reports were current and up-to-date. The well was in production with active chart record. The shared-use access road was in good condition. I walked and inspected the areas surrounding the wellhead and battery and found the natural greenscape to be free from signs of impact or degradation. |
187449013 | 2013-4-3 0:00:0 | UP | No Violations | |
1946229149 | 2010-10-12 | Preliminary Restoration | No Violations | No violation |
1958334173 | 2010-04-23 | Drill / Deepen / Reopen | No Violations | Talked with CJ Cutter no loss circulation or gas while drilling the 77/8 hole, I advised to cement the 4.5casing. |
2022844115 | 2014-02-20 | UrbanProduction Wells | No Violations | The unit is producing with no changes observed since the last inspection. No violations or problems. |
2099295281 | 2015-05-07 | UrbanProduction Wells | Violations Noted | I inspected this well location as part of routine inspection activity. The well is located in a clearing within a primarily wooded area. The entry to the well is gated with a cable-style gate which is locked. The access road is gravel-paved and accesses two wellheads (Callas 5 and 6D). At the time of this inspection, there are no wash-outs or erosional deficits. The wellhead is comprised of a pump jack unit in a board-on-board enclosure which is locked. The shared tank battery is comprised of a total of four 140-barrel steel production tanks, one 100-barrel steel brine tank, and two mechanical separators. The entry door is secure and locked. At the time of this inspection, the following maintenance issues were noted: Electrical boxes are not locked. Production tank lids are not latched down as required. Evergreen screening is needed at the battery and wellhead. Surface runoff from the battery area to the north towards a small creek has been altered resulting in ponding. This should be properly managed with a swale or similar engineering remedy. Signage is present but lacking complete information. The 8.625-inch casing is not exposed for monitoring as required. In addition, the following safety issues were noted. Load lines are not locked. Production tanks are missing lightning arrestors. Brine is actively leaking from the 2-inch flange at the brine tank. The dike drain has been left open. These safety issues must be remedied as soon as practicable or by 06/19/2015. Please contact Inspector Stephen Tompkins with questions regarding this Compliance Notice. |
2107413754 | 2014-07-10 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activities. The wellhead which is currently fitted with a pump jack system is in operation. Production reports are current. System operation at the above-ground storage tank (AST) battery appears normal. Safety apparatus are present and I observed no signs of leaks, spills, or problems. |
232417946 | 2010-2-16 0:00: | AM | No Violations | |
409031910 | 2020-3-9 0:00:0 | UP | No Violations | |
543254216 | 2015-4-2 0:00:0 | UP | No Violations | 0.50 |
922110022 | 2010-4-24 0:00: | DD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
2099295281 | US-OH-121439 | 2015-11-13 | LOCKS | |
2099295281 | US-OH-121440 | 2015-11-13 | TANKS (a-i) | |
2099295281 | US-OH-121441 | 2015-11-13 | Well operation causing pollution and contamination | |
2099295281 | US-OH-121442 | 2015-11-13 | No SPCC dike/or failure to keep dike free of water or oil |
For data sources see[9]