If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-22155 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.43,"lon":-81.57,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: NEO PARK LTD | |
License Status: Producing | |
License Date: 2010-03-31 | |
Spud Date: 2010-06-02 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2010-06-08 | |
Well Total Depth: 3448.00 ft | |
Configuration: Vertical | |
Latitude: 41.430000 | |
Longitude: -81.570000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2010-03-31 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:3/31/2010, Expired Date:3/31/2011 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2010-06-08 | |
Completion Report Received | 2010-11-09 | |
Construction Permit Expires | 2011-03-31 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-12-20 | 3264 | 3294 | 34 |
3264 | 3294 | 34 | |
3264 | 3294 | 34 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 52332 Gal | 30000 | Superior Well Services |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | BASS ENERGY CO INC | 0.00 | 0.00 | 0 |
2011 | BASS ENERGY CO INC | 8020.00 | 85.00 | 0 |
2012 | BASS ENERGY CO INC | 5887.00 | 83.00 | 366 |
2013 | BASS ENERGY CO INC | 4688.00 | 0.00 | 365 |
2014 | BASS ENERGY CO INC | 4374.00 | 33.00 | 365 |
2015 | BASS ENERGY CO INC | 3991.00 | 0.00 | 365 |
2016 | BASS ENERGY CO INC | 3664.00 | 0.00 | 365 |
2017 | BASS ENERGY CO INC | 3432.00 | 0.00 | 365 |
2018 | BASS ENERGY CO INC | 3232.00 | 68.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | BASS ENERGY CO INC | Brine | 70 | 0 |
2011 | BASS ENERGY CO INC | Brine | 192 | |
2012 | BASS ENERGY CO INC | Brine | 150 | 366 |
2013 | BASS ENERGY CO INC | Brine | 0 | 365 |
2014 | BASS ENERGY CO INC | Brine | 75 | 365 |
2015 | BASS ENERGY CO INC | Brine | 88 | 365 |
2016 | BASS ENERGY CO INC | Brine | 0 | 365 |
2017 | BASS ENERGY CO INC | Brine | 0 | 365 |
2018 | BASS ENERGY CO INC | Brine | 88 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1856272325 | 2010-6-8 0:00:0 | UD | No Violations | |
-1898187959 | 2013-6-5 0:00:0 | UL | No Violations | |
-720961985 | 2010-6-3 0:00:0 | UD | No Violations | |
0471294970 | 2017-10-20 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located on a parcel otherise occupied by a multi-tenant office park. At the time of this inspection, I observed the following: a wellhead with plunger lift system which was in operation. Fittings and connections at the well were secure and free from signs of leakage or problems. The board-on-board enclosure was locked and secure. The associated tank battery is located in a separate board-on-board enclosure which was locked and secure. The fittings and connections were secure. The secondary containment was intact and dry. Signage was present. I walked the areas surrounding the well and battery and found no signs of degradation or impact to the natural greenscape. |
0597437061 | 2010-06-04 | Urban Drill / Deepen / Reopen | No Violations | witnessed BOP testing (passed) |
0720961985 | 2010-06-03 | Urban Drill / Deepen / Reopen | No Violations | Cemented conductor casing. |
1144567597 | 2012-01-12 | UrbanPreliminary Restoration | No Violations | On 01/12/2012, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed. |
1276002529 | 2010-06-02 | Drill / Deepen / Reopen | No Violations | making location, change in permit conditions rig orientation change to east to west pits to north. |
1281977334 | 2010-03-25 | Administrative Inspection | No Violations | Held on site meeting to discuss the site construction and permit condition. |
1332169492 | 2010-06-04 | Urban Drill / Deepen / Reopen | No Violations | Cementing surface casing (85/8) good returns to surface. |
1491531618 | 2010-06-07 | Urban Drill / Deepen / Reopen | No Violations | Site inspection no violation. |
1734676291 | 2013-10-24 | UrbanProduction Wells | No Violations | Unit is producing and no changes from the prior inspection. No leaks or problems observed. |
1856272325 | 2010-06-08 | Urban Drill / Deepen / Reopen | No Violations | cementing 4.5 casing |
1898187959 | 2013-06-05 | UrbanPreliminary Restoration | No Violations | The unit consists of a producing wellhead and tank battery, both of which are in board-on-board enclosures and locked. The wellhead consists of a mechanical lift unit and is producing. The annular space is exposed and plumbed into production. The tank battery is comprised of 1 low-boy 100 barrel tans and 1 50 barrel tank. HB 278 equipment is in place and the secondary containment is good. The interior spacing is in accordance with the rules. There is also a Dominion metering run in the battery. I did not observe any problems or violations. The unit passes preliminary restoration. |
471294970 | 2017-10-20 0:00 | UP | No Violations | 0.50 |
597437061 | 2010-6-4 0:00:0 | UD | No Violations |
For data sources see[9]