Well Details

Well ID: 34-035-22192
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: BLOSSOM HILL
License Status: Producing
License Date: 2011-07-06
Spud Date: 2011-08-05
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2011-08-11
Well Total Depth: 3706.00 ft
Configuration: Vertical
Latitude: 41.300000
Longitude: -81.650000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-07-06 Proposed Formations:ORISKANY/CLINTON, Issued Date:7/6/2011, Expired Date:7/5/2013 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-08-11
Completion Report Received 2011-09-13
Construction Permit Expires 2012-07-05
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-12-01 3535 3536 2
2011-12-01 3533 3534 2
3531 3532 2
3533 3534 2
3535 3536 2
3544 3548 10
3552 3553 2
3555 3592 36
3588 3589 2
3531 3532 2
2011-12-01 3531 3532 2
2011-12-01 3544 3548 10
2011-12-01 3588 3589 2
2011-12-01 3555 3592 36
2011-12-01 3552 3553 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-08-23 H2O 15 130370 Gal 0 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 DUCK CREEK ENERGY INC 32383.00 101.00 81
2012 DUCK CREEK ENERGY INC 21464.00 292.00 366
2013 DUCK CREEK ENERGY INC 24565.00 127.00 365
2014 DUCK CREEK ENERGY INC 11650.00 68.00 365
2015 DUCK CREEK ENERGY INC 8312.00 58.00 365
2016 DUCK CREEK ENERGY INC 5915.00 0.00 365
2017 DUCK CREEK ENERGY INC 5717.00 63.00 365
2018 DUCK CREEK ENERGY INC 4698.00 58.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 DUCK CREEK ENERGY INC Brine 358 81
2012 DUCK CREEK ENERGY INC Brine 476 366
2013 DUCK CREEK ENERGY INC Brine 198 365
2014 DUCK CREEK ENERGY INC Brine 129 365
2015 DUCK CREEK ENERGY INC Brine 70 365
2016 DUCK CREEK ENERGY INC Brine 129 365
2017 DUCK CREEK ENERGY INC Brine 67 365
2018 DUCK CREEK ENERGY INC Brine 40 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-256406805 2011-8-5 0:00:0 UD No Violations
-941469808 2013-7-18 0:00: UL No Violations
0256406805 2011-08-05 Urban Drill / Deepen / Reopen No Violations Covering surface job. Good cement retures to surface.
0683432501 2018-01-03 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The linear rod pump well and tank battery are located on a parcel utilized for municipal facilities, with separate, shared-use access roads for the well and for the battery which is shared with the #2-2129 well. I found the wellhead and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems. There were several inches of snow in the area.
0941469808 2013-07-18 UrbanPreliminary Restoration No Violations The producing unit consists of a wellhead with linear rod pump unit and an aboveground storage tank (AST) battery with two steel 140-barrel production tanks, one steel 140-barrel brine tank, 2 mechanical separators, and metering run.. The unit ID is present and meets requirements. The loadouts are locked and bull-plugged. The battery secondary containment is good. The wellhead and battery are in separate board-on-board enclosures. Safety equipment is present in accordance with 1501:9-9-05E. I did not observe any evidence of leakage or spills. The battery is shared with the Blossom Hill 3 unit (3403522129). The access road gate is locked and there is no ID placard.
1248906756 2015-03-30 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The wellhead is located near the intersection of Oakes and Barr Rds. And is accessed via a dedicated access road from Barr Rd. The battery is located behind the City of Brecksville Service Building and the Blossum Hill Church. Access to the well and battery are from a dedicated access road adjacent to the service building. The wellhead is comprised of a linear road pump system in a locked board-on-board enclosure. Fittings and connections are secure. The tank battery is comprised of 2 100-barrel steel production tanks, 1 100-barrel steel brine tank and separator unit in a separate board-on-board enclosure. Elements of the system are in general good repair. Fittings and connections are secure and free from signs of leakage at the time of this inspection. The load-outs are plugged and secure. ID signage and secondary containment are present. Areas surrounding the wellhead and battery are reasonably well drained and free from signs of adverse impact from the on-going production activity associated with this well. The battery is shared with the Blossum Hill #2-2129 well which is adjacent to the battery.
1466771086 2017-06-30 UrbanProduction Wells No Violations I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with linear rod pump system and associated tank battery. The well is located on the eastern portion of park property and accessed from Barr Road. The shared battery is located on an otherwise undeveloped property located adjacent to the Brecksville Service Garage. The individual enclosures were locked and secure. The load-line valves were locked and plugged. The dedicated lease road was exhibiting some potholes and wear but was passable. Fittings and connections were secure and free from signs of leakage or problems.
1536676579 2018-09-11 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: the well with linear rod pump system was in active production. The various fittings and connections were secure and free from leakage. The associated tank battery is located west of the well, and shared with the Blossom Hill #3 well located adjacent to the tank battery. Fittings and connections were secure. The load-line valves were plugged and secure. The chart record was active. The secondary containment was intact with some impounded water from recent rainfall. There was no sheen or other signs of spills or leaks within the containment. The separate access roads that service both the well and battery were in good condition.
683432501 2018-1-3 0:00:0 UP No Violations

For data sources see[9]