If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-22196 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.34,"lon":-81.8,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: M & M ROYALTY LTD | |
Well Pad ID: | |
Farm/Lease Name: VARGA UNIT | |
License Status: Final Restoration | |
License Date: 2015-07-02 | |
Spud Date: 2012-06-18 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2012-06-22 | |
Well Total Depth: 3216.00 ft | |
Configuration: Vertical | |
Latitude: 41.340000 | |
Longitude: -81.800000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2011-09-30 | Proposed Formations:CLINTON, Issued Date:9/30/2011, Expired Date:9/29/2013 12:00:00 PM, Drilling unit acres:22.5, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2012-06-22 | |
Completion Report Received | 2012-09-24 | |
APP | 2015-07-02 | Proposed Formations:CLINTON, Issued Date:7/2/2015, Expired Date:7/1/2017 12:00:00 PM, Drilling unit acres:22.5, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2015-08-21 | |
Construction Permit Expires | 2016-07-01 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2012-09-27 | 3018 | 3036 | 37 |
2012-09-27 | 3048 | 3050 | 50 |
3018 | 3036 | 37 | |
3048 | 3050 | 50 | |
3018 | 3036 | 37 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2012-08-29 | H2O | 0 | 53000 Gal | 50000 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | M & M ROYALTY LTD | 0.00 | 0.00 | 0 |
2013 | M & M ROYALTY LTD | 0.00 | 108.00 | 0 |
2015 | M & M ROYALTY LTD | 0.00 | 50.00 | 30 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | M & M ROYALTY LTD | Brine | 0 | 0 |
2013 | M & M ROYALTY LTD | Brine | 161 | 0 |
2015 | M & M ROYALTY LTD | Brine | 125 | 30 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-767618242 | 2012-6-13 0:00: | SC | No Violations | 2.00 |
0060796965 | 2012-06-19 | Urban Drill / Deepen / Reopen | No Violations | My visit to the well today was to set and cement the surface casing to permit standards. |
0642148484 | 2013-02-27 | UrbanProduction Wells | No Violations | The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead consists of a pumpjack system. The tank battery is comprised of 1 100-barrel (BBL) tank, 50 BBL tank, mechanical separator, and associated piping and appurtenances. The unit is not yet in production and still undergoing construction. I did not observe any leaks, releases, or problems. |
0767618242 | 2012-06-13 | Surface Facility Construction | No Violations | I visited the well site today to inspect well site construction. Construction is complete and ready for rig move on. Well site constructed using best management practices and in accordance with Urban Pre Site conditions. |
1292209460 | 2014-07-07 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity and also as a follow-up to my last inspection. At that time, the well was idle pending a decision to continue attempts to produce the well or plug and abandon. Conversations with M&M indicate the well has produced a lot of brine fluids and plugging is being considered. Currently the well remains idle. Conditions at the well remain static with no changes or indications of problems. |
1334142771 | 2016-08-24 | Final Restoration | No Violations | I inspected this well location for evaluation for Final Restoration requirements. At the time of this inspection, I observed the following: the area of the former well had been restored to original grade and vegetation is well established. Production equipment has been removed. The dedicated portion of the lease road, along with the existing flowline and the pre-point-of-sale portion of the sales line, will remain with approval of the landowner. I met with the landowner during my inspection and he indicated that he was satisfied with restoration. Final Restoration is complete. |
1340148532 | 2012-06-18 | Urban Drill / Deepen / Reopen | No Violations | My visit to the well today was for the purpose of setting the conductor casing to permit standards. |
1340181031 | 2012-06-20 | Urban Drill / Deepen / Reopen | No Violations | My visit to the well on this date was to witness the Blow Off Preventer (BOP) test. Pressure was set at 180 PSI for fifteen minutes. Pressure held with no bleed off or reduction. BOP passed 2:45 AM. |
1348684546 | 2012-09-26 | UrbanProduction Wells | No Violations | Inspected well at request of Steve Opritza, from permitting office in Columbus. Spacing question on tank battery location from property line. Spacing requirement is 75 from line, tank battery location is approximately 102.5 from line. Tank battery location is being completed but tanks have not yet been installed and equipment is sitting on lessees property awaiting completion of tank battery location. |
1378398093 | 2013-09-05 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a producing wellhead with pumpjack and aboveground storage tank battery. The wellhead is enclosed in a temporary fence structure. The battery is comprised of three 100-barrel production tanks and one 50-barrel brine tank. The secondary containment is good. 1501:9-9-05E safety equipment is present. There is no unit ID at the tank battery. I will contact M&M regarding the temporary fencing and the ID. This unit does not pass preliminary restoration. |
1440155134 | 2015-08-21 | Plug / Plug Back | No Violations | I was on location for plugging and abandonment activity which commenced on 08/20 with removal of rods and tubing. Tank battery elements have been dismantled. Details of the plugging and abandonment can be found in the associated plugging report. |
60796965 | 2012-6-19 0:00: | UD | No Violations | 4.00 |
642148484 | 2013-2-27 0:00: | UP | No Violations |
For data sources see[9]