If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-22201 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.32,"lon":-81.69,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: TOLCO UNIT | |
License Status: Producing | |
License Date: 2012-05-11 | |
Spud Date: 2012-07-06 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2012-07-11 | |
Well Total Depth: 3542.00 ft | |
Configuration: Vertical | |
Latitude: 41.320000 | |
Longitude: -81.690000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-05-11 | Proposed Formations:CLINTON, Issued Date:5/11/2012, Expired Date:5/11/2014 12:00:00 PM, Drilling unit acres:20.57, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2012-07-11 | |
Completion Report Received | 2012-08-03 | |
Construction Permit Expires | 2013-05-11 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2012-08-09 | 3380 | 3450 | 60 |
3380 | 3450 | 60 | |
3380 | 3450 | 60 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2012-07-20 | H2O | 15 | 146382 Gal | 0 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | DUCK CREEK ENERGY INC | 9382.00 | 2978.00 | 365 |
2014 | DUCK CREEK ENERGY INC | 7601.00 | 1704.00 | 365 |
2015 | DUCK CREEK ENERGY INC | 5300.00 | 1030.00 | 365 |
2016 | DUCK CREEK ENERGY INC | 4656.00 | 685.00 | 365 |
2017 | DUCK CREEK ENERGY INC | 3500.00 | 643.00 | 365 |
2018 | DUCK CREEK ENERGY INC | 2670.00 | 307.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | DUCK CREEK ENERGY INC | Brine | 2369 | 365 |
2014 | DUCK CREEK ENERGY INC | Brine | 1038 | 365 |
2015 | DUCK CREEK ENERGY INC | Brine | 866 | 365 |
2016 | DUCK CREEK ENERGY INC | Brine | 770 | 365 |
2017 | DUCK CREEK ENERGY INC | Brine | 683 | 365 |
2018 | DUCK CREEK ENERGY INC | Brine | 560 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1746171028 | 2012-7-2 0:00:0 | SC | No Violations | 1.00 |
-540874986 | 2020-2-6 0:00:0 | UP | No Violations | |
0816238387 | 2018-02-08 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. At the time of this inspection, fittings and connections at the wellhead linear rod pump and battery were secure and free from leakage or problems. The individual enclosures were locked and secure. Production reports were current. Proper bonding and insurance was in place. The well was in active production,. |
1185752602 | 2015-05-22 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. The well is producing and production records are current. Entry gates are locked and secure, at both the wellhead and battery. Process safety equipment is present. Fittings and connections are secure and free from signs of leakage or problems. Tank hatches are closed and secure. The short, paved access road is dry, level, and well drained. At the time of this inspection, I observed the following deficiencies: The load line is not lock protected, ID signage is lacking required information. Warning signage is incomplete. These deficiencies must be corrected as soon as practicable or by 06/29/2015. Please contact Inspector Stephen Tompkins at 330-907-4647 for questions regarding this inspection. |
1341329143 | 2012-06-27 | Surface Facility Construction | No Violations | My visit to this well was to check the site preparation process for anticipated move onto site by Poulson drilling next week. |
1443931463 | 2012-11-07 | UrbanPreliminary Restoration | No Violations | My visit to the well today was for an Urban Preliminary Inspection. This unit consists of a Linger Rod Vertical pump unit and there is 200 PSI at the annulus. Tank battery consists of two (2) 140 Barrel lowboy tank units with vents, charcoal filter units for each tank. Well site is in good condition and dike around tank unit is capable of holding fluids per 1501:9-9-05. The preliminary restoration is not complete, as site has not been seeded due to considerable rainfall since the well was completed. Discussed situation with maintenance foreman, Larry Gibler. He assured me that as soon as weather permits he would plant seed. |
1536984406 | 2014-07-14 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of customary and routine inspection activities. The producing unit is comprised of a wellhead with valve assembly and linear rod pump system. The unit is producing and production reports are current. ID placards are present and have current and accurate contact information. The tank battery is comprised of 2 100-barrel steel production tanks, 1 50-barrel brine tank, and separator unit. There is a Dominion metering run in the enclsoure. The secondary containment dike is is good condittion. The battery lies wtihin a naturally low-lying area and drainage is likely from infiltration. I did not observe any signs of gully formation, wash-outs, or other impacts associated with the unit. Enclosure gates are locked. I did not observe any signs of leakage, spills, or other problem conditions. |
1746171028 | 2012-07-02 | Surface Facility Construction | No Violations | Stopped by location to check site preparation for equipment move on. Anticipated moving to begin today. Rig not yet completed with current well in Portage County. |
1926053644 | 2015-09-03 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to an earlier Compliance Notice. The load-lines are now lock-protected. The ID signage has been updated and is complete. Warning signs are now posted at the well and battery as required. Fittings and connections at the battery and wellhead are secure. Enclosure gates and electrical panels are locked and secure. The battery secondary containment is intact and free from signs of leakage or problems. Spark arrestors, low-pressure relief valves, and carbon filter is present. The tank lids are closed and secure. The 8.625-inch well casing is exposed and open to atmosphere. There is no discernible gas venting from the casing. The previous violations have been addressed. |
2044473793 | 2015-01-14 | UrbanProduction Wells | No Violations | I inspected this producing unit as port of routine inspection activity. The wellhead linear rod pump system is located in a board-on-board enclosure in an open lot. The surrounding area is comprised primarily of residential apartments and some single-family homes. The battery is located via a short (250 ft.) dedicated access road which terminates in a wooded area. Access gates at the battery and wellhead are locked and secure. Load-outs at the battery are bull-plugged and secure. Connections and fittings are secure and free from signs of leakage or other problems. |
816238387 | 2018-2-8 0:00:0 | UP | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1185752602 | US-OH-104911 | 2016-07-26 | 9-05E1 | ID (a-i) |
1185752602 | US-OH-104912 | 2015-11-13 | LOCKS |
For data sources see[9]