X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-037-60038

Well Details

Well ID: 34-037-60038
Loading map...
Country: United States
State: Ohio
County: Darke
Municipality: Allen Township
Operator Name: HISTORIC OWNER
Well Pad ID:
Farm/Lease Name: SCHMITZ CLETUS
License Status: Final Restoration
License Date:
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 40.320000
Longitude: -84.700000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Well Added to System 2007-07-10 I&O CASE # 1993 05 037; NO PREVIOUS RECORD OF WELL; WILL NEED TO CORRECT THE WELL LOCATION WHEN GET A GPS LOCATION.
Plugged by Orphan Well Program 2018-05-31 Plugged by Orphan Well Program
Plugged/Abandoned 2018-05-31 I&O CASE # 1993 05 037; NO PREVIOUS RECORD OF WELL; WILL NEED TO CORRECT THE WELL LOCATION WHEN GET A GPS LOCATION. UPDATED LOCATION PER SURVEYOR COORDINATES-ALE 06/20/17
Record Last Modified 2019-05-10 I&O CASE # 1993 05 037; NO PREVIOUS RECORD OF WELL; WILL NEED TO CORRECT THE WELL LOCATION WHEN GET A GPS LOCATION. UPDATED LOCATION PER SURVEYOR COORDINATES-ALE 06/20/17

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1656731202 2012-12-6 0:00: OR No Violations
-313517872 2012-9-17 0:00: OR No Violations
-323130955 2014-2-3 0:00:0 OR No Violations
-54865526 2018-5-29 0:00: PB No Violations
-780685918 2018-6-5 0:00:0 PB No Violations
0054865526 2018-05-29 Plug / Plug Back No Violations Witnessed the installation of 7 sacks of Class A Cement inside of the 2 inch tubing. Jet Wireline determined that the tubing was free at a depth of 350 feet deep. The tubing was shot at that depth and removed. Ran 1.5 inch tubing to a depth of 350 feet and pumped 70 sacks od Class A Cement. Cement was not observed at surface.
0313517872 2012-09-17 Orphan No Violations A follow-up inspection revealed that the well consisted of 8 drive pipe, and 6 casing with a wellhead. The 8 casing was peeled to allow for installation of wellhead. The well contained rods and tubing with no pumping unit. A section of rod and tubing were also bent below the pumping tee. There were no observed production line(s) or related tanks. The well is situated on a property designated as agricultural field (corn field) with no overhead obstructions. An access/lease road will need to be constructed and may require a culvert at the entrance. Note: Well location(s) were previously scaled and have now been corrected with GPS readings.
0323130955 2014-02-03 Orphan No Violations This inspection was done to review the location to complete the plugging Scope of Work for the Orphan Well Program. There was no change in the status of the well from previous inspections. All GPS readings were verified and updated pictures were taken.
0535985718 2018-05-31 Plug / Plug Back No Violations Installed 11 sacks of Class A Cement in order to top off this well after cement was measured at a depth of 70 feet.
0780685918 2018-06-05 Plug / Plug Back No Violations Operator ran approximately 790 feet of 1.5 inch tubing into well. Operator pumped 125 sacks of Class A Cement through the tubing and cement was observed at the surface.
0966720200 2018-05-30 Plug / Plug Back No Violations Measured the top of the cement plug that was installed yesterday and determined it to be at a depth of 70 feet deep.
1260714659 2018-07-03 Final Restoration No Violations Final restoration is not approved. Plugging contractors equipment has been removed from site and wells have been cut off and backfilled. Plugging contractor will need to grade driveway used for access before final restoration will be approved.
1656731202 2012-12-06 Orphan No Violations A follow-up inspection conducted with Orphan Well Program Supervisor, Mr. Gene Chini revealed no change to the well status since the last inspection. There was no discharge of fluid or natural gas detected with a meter. The well consisted of 8 peeled drive pipe, Approx 5.83 casing with a wellhead, rods and tubing. The top section of rod was bent below the tee. The well is situated on a property designated as agricultural field. During the inspection of all wells located on this property, the landowner, Mr. Donald Schmitz confirmed the installation of field tile. Mr. Schmitz stated that the tiles were placed 20 apart and routed to the north and south. Steel tanks will be utilized in place of earthen pits. Mr. Schmitz requested for casing to be cut and buried 4 below ground level. A lease road does not exist for wells located on this property. However, the best access to the wells would be a gravel entrance to the field located off N. Star Fort Loramie Rd and not Lightsville Northern Rd.
257625671 2019-12-31 0:00 FR No Violations 0.20
535985718 2018-5-31 0:00: PB No Violations
966720200 2018-5-30 0:00: PB No Violations

For data sources see[3]

References