34-045-21039

Well Details

Well ID: 34-045-21039
Loading map...
Country: United States
State: Ohio
County: Fairfield
Municipality: Liberty Township
Operator Name: SERMON TRESSIE & NAOMI
Well Pad ID:
Farm/Lease Name: SERMON T
License Status: Domestic Well
License Date: 1987-09-14
Spud Date: 1987-09-26
Spud Drilling Contractor: LOTHES & LOTHES
Final Drill Date: 1987-10-29
Well Total Depth: 1830.00 ft
Configuration: Vertical
Latitude: 39.910000
Longitude: -82.680000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1987-09-14 Issued Date 9/14/87 Expired Date 9/13/88 Acres 0020000 Tool Type CT Proposed Formation CLINTON Proposed Depth 01830 Proposed Drill Depth 01830
Original Spud 1987-09-26
Completed 1987-10-29
Reached Total Depth 1987-10-29
CO 1987-12-05 3378 SERMON TRESSIE & NAOMI GeoDate 9/14/87
Completion Report Received 1988-01-28
Construction Permit Expires 1988-09-13
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 0 0
1788 1830 0
1997-06-29 1788 1830 0
0 0
0 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 250 Gal 0
H2O 0 993 Bbl 40000 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 PROTECH ENERGY INC 456.00 0.00 27
1988 HELDMAN DONALD R 2272.00 0.00 360

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 PROTECH ENERGY INC Brine 47 27
1988 HELDMAN DONALD R Brine 110 360

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1182710481 2018-12-31 0:00 PW No Violations 0.90
-188718241 2019-1-10 0:00: PW No Violations 0.60
-845071970 2015-11-2 0:00: PW No Violations 3.00
0188718241 2019-01-10 Production Wells No Violations My inspection revealed the well does not have a legible identification. I met with the owner of the well and I gave him the needed information to legible identify the well. I asked to be called when the well had the identification.
0777239823 2019-05-03 Production Wells No Violations My inspection revealed this well had legible identification. This satisfies the compliance notice.
0845071970 2015-11-02 Production Wells No Violations I received a request from Jake Glascock to inspect this well. The request is due to a water well complaint he has received. The well consists of a pumping unit and 1-20 barrel tank. No violations were noted at the time of my inspection.
1182710481 2018-12-31 Production Wells No Violations My inspection revealed this well consisted of a pumping unit. The valves on the wellhead were in the open position. The tank battery consisted of a separator and two poly tanks. There was a 1-100 barrel tank that was disconnected from the plumbing. The well lacked a legible identification. The owner of the well shall place a legible identification at the wellhead or at the tank battery. The identification shall include, owner, lease name, well number, permit number, county and a emergency phone number.
1383809370 2019-04-18 Production Wells No Violations My inspection revealed this was not in compliance. The well lacked a legible identification. I met with the owner of the well and provided him with the necessary information for the identification.
777239823 2019-5-3 0:00:0 PW No Violations 0.60
854434758 2019-12-31 0:00 PW No Violations 0.30

For data sources see[9]