If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-055-20049 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.41,"lon":-81.25,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Auburn Township | |
Operator Name: DIVERSIFIED PRODUCTION LLC | |
Well Pad ID: | |
Farm/Lease Name: FRANKS E ET AL | |
License Status: Producing | |
License Date: 1972-08-11 | |
Spud Date: 1972-09-11 | |
Spud Drilling Contractor: | |
Final Drill Date: 1972-09-15 | |
Well Total Depth: 4080.00 ft | |
Configuration: Vertical | |
Latitude: 41.410000 | |
Longitude: -81.250000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1972-08-11 | 133 QUAKER STATE OIL REF CORP GeoDate 8/11/72 |
Original Spud | 1972-09-11 | REV. LOC. 9-13-72 |
Completed | 1972-09-15 | REV. LOC. 9-13-72 |
Reached Total Depth | 1972-09-15 | REV. LOC. 9-13-72 |
Construction Permit Expires | 1973-08-11 | REV. LOC. 9-13-72 |
CO | 1995-10-18 | 182 BELDEN & BLAKE CO GeoDate 8/11/72 |
Change of Owner | 2007-04-27 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC |
Change of Owner | 2017-05-01 | Operator changed from 7578, ENERVEST OPERATING LLC, to 8685, M & R INVESTMENTS OHIO LLC |
Record Last Modified | 2017-05-01 | REV. LOC. 9-13-72 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3908 | 3947 | 18 |
3908 | 3947 | 18 | |
3908 | 3947 | 18 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 2045 Bbl | 45000 | R.P. 2 HRS. NSR |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | QUAKER STATE OIL REF CORP | 4532.00 | 41.00 | 0 |
1985 | QUAKER STATE OIL REF CORP | 4510.00 | 38.00 | 365 |
1986 | QUAKER STATE OIL REF CORP | 3624.00 | 73.00 | 365 |
1987 | QUAKER STATE OIL REF CORP | 3391.00 | 1.00 | 365 |
1988 | QUAKER STATE OIL REF CORP | 7003.00 | 0.00 | 365 |
1989 | QUAKER STATE OIL REF CORP | 5181.00 | 47.00 | 365 |
1990 | QUAKER STATE OIL REF CORP | 6331.00 | 0.00 | 365 |
1991 | QUAKER STATE OIL REF CORP | 6366.00 | 19.00 | 365 |
1992 | QUAKER STATE OIL REF CORP | 5397.00 | 28.00 | 365 |
1993 | QUAKER STATE OIL REF CORP | 5309.00 | 20.00 | 365 |
1994 | QUAKER STATE OIL REF CORP | 2390.00 | 23.00 | 365 |
1995 | BELDEN & BLAKE CORPORATION | 407.00 | 0.00 | 130 |
1997 | BELDEN & BLAKE CORPORATION | 2202.00 | 0.00 | 330 |
1998 | BELDEN & BLAKE CORPORATION | 1701.00 | 72.00 | 154 |
1999 | BELDEN & BLAKE CORPORATION | 382.00 | 0.00 | 303 |
2000 | BELDEN & BLAKE CORPORATION | 2183.00 | 0.00 | 366 |
2001 | BELDEN & BLAKE CORPORATION | 2904.00 | 0.00 | 319 |
2002 | BELDEN & BLAKE CORPORATION | 3420.00 | 46.00 | 331 |
2003 | BELDEN & BLAKE CORPORATION | 2138.00 | 0.00 | 240 |
2004 | BELDEN & BLAKE CORPORATION | 58.00 | 0.00 | 366 |
2005 | BELDEN & BLAKE CORPORATION | 0.00 | 0.00 | 365 |
2006 | BELDEN & BLAKE CORPORATION | 0.00 | 0.00 | 365 |
2007 | ENERVEST OPERATING LLC | 0.00 | 0.00 | 0 |
2008 | ENERVEST OPERATING LLC | 0.00 | 0.00 | 0 |
2009 | ENERVEST OPERATING LLC | 8652.00 | 0.00 | 365 |
2010 | ENERVEST OPERATING LLC | 4994.00 | 57.00 | 365 |
2011 | ENERVEST OPERATING LLC | 3175.00 | 0.00 | 0 |
2012 | ENERVEST OPERATING LLC | 2971.00 | 0.00 | 366 |
2013 | ENERVEST OPERATING LLC | 2602.00 | 0.00 | 365 |
2014 | ENERVEST OPERATING LLC | 1373.00 | 0.00 | 365 |
2015 | ENERVEST OPERATING LLC | 1425.00 | 0.00 | 365 |
2016 | ENERVEST OPERATING LLC | 1598.00 | 0.00 | 366 |
2017 | M & R INVESTMENTS OHIO LLC | 542.00 | 0.00 | 365 |
2018 | M & R INVESTMENTS OHIO LLC | 707.00 | 30.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-411587082 | 2014-8-19 0:00: | UP | No Violations | |
-417716884 | 2017-1-11 0:00: | UP | No Violations | |
0411587082 | 2014-08-19 | UrbanProduction Wells | No Violations | My inspection found the well to be equipped with a plunger lift unit. The tank battery consists of a 100 BBL production tank. The verticle mechanical separator is outside of the tank battery. The dike needs rebuilt around the tank battery. The fitting on the base of the separator is leaking and the ground is stained with oil. The proper identification is on the tank battery. The lease road is in stable condition. I contacted Kyle Ahbel a supervisor from Enervest about the issues and getting them repaired. |
0417716884 | 2017-01-11 | UrbanProduction Wells | No Violations | During this inspection, it was observed that the well was equipped with a plunger lift assembly and the valves on the wellhead were open. There was a domestic line with a meter, drip bottle and three regulators plumbed off the 4.5 inch casing. The last reported production for this well was in 2015. The tank battery consisted of one 100 BBL production tank and a mechanical separator. The valves on the separator were open and the chart on the sales line showed production. The tank battery was diked and the tank valve was equipped with a flat plug. The proper, legible signage was located at tank battery and the lease access was stable. |
1419876766 | 2014-12-29 | UrbanProduction Wells | No Violations | My inspection found the dike around the tank battery has been rebuilt. The separator was not repaired and is leaking from the base. I contacted Kyle Ahbel about the repairs and was told he would have it repaired immediately. No other changes to the location since my last inspection. |
1433343645 | 2015-06-03 | UrbanProduction Wells | No Violations | My inspection found the fitting that was leaking at the base of the separator has been repaired. No other changes to the location since my last inspection. No violations found. |
For data sources see[9]