If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-055-20181 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.41,"lon":-81.07,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Parkman Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: YODER S | |
License Status: Producing | |
License Date: 1982-07-22 | |
Spud Date: 1975-12-13 | |
Spud Drilling Contractor: | |
Final Drill Date: 1977-06-22 | |
Well Total Depth: 4233.00 ft | |
Configuration: Vertical | |
Latitude: 41.410000 | |
Longitude: -81.070000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1975-12-13 | |
Completed | 1977-06-22 | |
Reached Total Depth | 1977-06-22 | |
CO | 1982-07-22 | 9 EDC GeoDate 7/22/82 |
Correction to Well | 2007-07-13 | UNIT SIZE INCREASED TO 99.36 ACRES. |
Change of Owner | 2008-07-21 | Operator changed from 9, POWER GAS MARKETING & TRANS to 1388, EXCO - NORTH COAST ENERGY INC |
Change of Owner | 2009-12-14 | Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC |
Record Last Modified | 2019-06-14 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4114 | 4143 | 19 |
4114 | 4143 | 19 | |
4114 | 4143 | 19 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1250 Bbl | 50000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-763143018 | 2013-4-23 0:00: | PW | No Violations | |
0763143018 | 2013-04-23 | Production Wells | No Violations | My inspection found the well to be equipped with a plunger lift unit. The annulus is open. The well and tank battery are in good repair. The tank battery consists of a 100 BBL production tank and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition. |
1186421544 | 2007-08-06 | Production Wells | No Violations | Tank battery has fluid within 3 inches of top of the dike, east side of the dike. The fluid is oil and brine. Pumper has a 4X4 board from the dike to the separator, so as not to have to walk in the oil. A stream is less than 20 down slope from the tank battery, the stream leads to a pond. Tank battery is not signed. There is a one hundred barrel tank on site, under ground tank and a plastic brine tank that is on its side. Called Andy Koval from the company at 12:24 pm 08/06/2007, he said he will have it clean up immediately. Andy Called me at 1:58 pm 08/06/2007 crew is on it and they are going to replace the tank. |
For data sources see[9]