Well Details

Well ID: 34-055-20257
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Middlefield Township
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: MILLER DAN J
License Status: Producing
License Date: 1976-09-03
Spud Date: 1976-09-16
Spud Drilling Contractor:
Final Drill Date: 1976-09-25
Well Total Depth: 4158.00 ft
Configuration: Vertical
Latitude: 41.460000
Longitude: -81.010000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1976-09-16
Completed 1976-09-25
Reached Total Depth 1976-09-25
Completion Report Received 1977-07-15
Change of Owner 2004-07-01 Operator changed from 351, BATES LEW JR to 6295, KNOX ENERGY INC.
Change of Owner 2004-08-02 Operator changed from 6295, KNOX ENERGY INC. to 7276, SELECT ENERGY INVESTMENTS INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-05-06 4039 4056 14
2006-09-11 4051 4056 6
4039 4056 14
4051 4056 6
4039 4056 14

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1425 Bbl 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 BATES LEW JR 1513.00 0.00 365
1987 BATES LEW JR 992.00 0.00 365
1988 BATES LEW JR 801.00 0.00 365
1996 BATES LEW JR 189.00 0.00 35
1997 BATES LEW JR 646.00 0.00 45
1998 BATES LEW JR 1469.00 0.00 365
1999 BATES LEW JR 2028.00 0.00 365
2000 BATES LEW JR 1788.00 0.00 365
2001 BATES LEW JR 1360.00 0.00 365
2002 BATES LEW JR 1938.00 0.00 365
2004 SELECT ENERGY INVESTMENTS INC 249.00 0.00 180
2005 SELECT ENERGY INVESTMENTS INC 1184.00 46.00 365
2006 SELECT ENERGY INVESTMENTS INC 589.00 0.00 365
2007 SELECT ENERGY INVESTMENTS INC 713.00 0.00 365
2008 SELECT ENERGY INVESTMENTS INC 699.00 0.00 365
2009 SELECT ENERGY INVESTMENTS INC 618.00 189.00 365
2010 SELECT ENERGY INVESTMENTS INC 822.00 144.00 365
2011 SELECT ENERGY INVESTMENTS INC 868.00 122.00 365
2012 SELECT ENERGY INVESTMENTS INC 819.00 63.00 366
2013 SELECT ENERGY INVESTMENTS INC 754.00 351.00 365
2014 SELECT ENERGY INVESTMENTS INC 1139.00 61.00 365
2015 SELECT ENERGY INVESTMENTS INC 356.00 109.00 365
2016 SELECT ENERGY INVESTMENTS INC 431.00 0.00 365
2017 SELECT ENERGY INVESTMENTS INC 416.00 130.00 365
2018 SELECT ENERGY INVESTMENTS INC 504.00 136.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 BATES LEW JR Brine 135 365
1987 BATES LEW JR Brine 0 365
1988 BATES LEW JR Brine 0 365
1996 BATES LEW JR Brine 0 35
1997 BATES LEW JR Brine 0 45
1998 BATES LEW JR Brine 0 365
1999 BATES LEW JR Brine 0 365
2000 BATES LEW JR Brine 0 365
2001 BATES LEW JR Brine 0 365
2002 BATES LEW JR Brine 0 365
2004 SELECT ENERGY INVESTMENTS INC Brine 0 180
2005 SELECT ENERGY INVESTMENTS INC Brine 0 365
2006 SELECT ENERGY INVESTMENTS INC Brine 0 365
2007 SELECT ENERGY INVESTMENTS INC Brine 0 365
2008 SELECT ENERGY INVESTMENTS INC Brine 0 365
2009 SELECT ENERGY INVESTMENTS INC Brine 53 365
2010 SELECT ENERGY INVESTMENTS INC Brine 151 365
2011 SELECT ENERGY INVESTMENTS INC Brine 41 365
2012 SELECT ENERGY INVESTMENTS INC Brine 0 366
2013 SELECT ENERGY INVESTMENTS INC Brine 39 365
2014 SELECT ENERGY INVESTMENTS INC Brine 18 365
2015 SELECT ENERGY INVESTMENTS INC Brine 18 365
2016 SELECT ENERGY INVESTMENTS INC Brine 18 365
2017 SELECT ENERGY INVESTMENTS INC Brine 0 365
2018 SELECT ENERGY INVESTMENTS INC Brine 10 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-324397746 2003-6-26 0:00: PW No Violations
0324397746 2003-06-26 Production Wells No Violations
1323089992 2015-03-25 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The well was previously equipped with a pumpjack. The rods are next to the well and have been cut into 5 ft lengths to be taken for scrap by the landowner. The tank battery consists of a 100 BBL production tank, a 100 BBL brine tank, and two mechanical separators. The vertical separator is corroded and is leaking from the base. The operator has absorbent pads laid underneath the separator. The pumpjack has been brought up to the tank battery and the landowner is going to scrap it as well as the rods. The proper identification is located on the tank battery. The lease road is in stable condition. I have contacted Richard Campola, the owner of Select Energy and his plans are to have the separator repaired.

For data sources see[9]