If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-055-20472 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.53,"lon":-81.14,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Claridon Township | |
Operator Name: DIVERSIFIED PRODUCTION LLC | |
Well Pad ID: | |
Farm/Lease Name: MUNSON LAMONT & GLORIA | |
License Status: Producing | |
License Date: 1983-03-23 | |
Spud Date: 1983-08-22 | |
Spud Drilling Contractor: SHERMAN DRLG | |
Final Drill Date: 1983-08-27 | |
Well Total Depth: 4043.00 ft | |
Configuration: Vertical | |
Latitude: 41.530000 | |
Longitude: -81.140000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1983-03-23 | 213 LOMAK OPERATING CO GeoDate 3/23/83 |
Oil and Gas | 1983-03-23 | Issued Date 3/23/83 Expired Date 9/19/83 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04043 Proposed Drill Depth 04043 |
Original Spud | 1983-08-22 | |
Completed | 1983-08-27 | |
Reached Total Depth | 1983-08-27 | |
Completion Report Received | 1983-08-29 | |
Construction Permit Expires | 1983-09-19 | |
Change of Owner | 1999-10-19 | Operator changed from 213, RANGE OPERATING COMPANY to 6570, OILFIELD SERVICES INC |
Change of Owner | 2002-12-12 | Operator changed from 6570, OILFIELD SERVICES INC to 7033, BROAD STREET ENERGY COMPANY |
Change of Owner | 2015-07-16 | Operator changed from 8685, M & R INVESTMENTS OHIO LLC BROAD STREET ENERGY COMPANY to 8685, M & R INVESTMENTS OHIO LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3860 | 3948 | 0 |
3860 | 3948 | 0 | |
2006-09-11 | 3866 | 3914 | 2 |
3866 | 3914 | 2 | |
3860 | 3948 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 60000 Gal | 50000 | FRAC;60MG H2O,50M# SD |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-191560502 | 2003-3-11 0:00: | PW | No Violations | |
-841798042 | 2016-3-23 0:00: | PW | No Violations | |
-995651146 | 2013-11-15 0:00 | PW | No Violations | |
0146672319 | 2004-04-01 | Production Wells | No Violations | TB only 2-210 bbls, seperator, dike. |
0153914437 | 2014-08-18 | Production Wells | No Violations | My inspection found no change since my last inspection. I have contacted the company and they intend to plug the well. |
0191560502 | 2003-03-11 | Production Wells | No Violations | |
0299921047 | 2003-03-11 | Production Wells | No Violations | |
0841798042 | 2016-03-23 | Production Wells | No Violations | My inspection found no changes to the location since my last inspection. John Raber from M&R Investments was to contact me in January with a plan to get the well back into production. I contacted Mr. Raber and he stated that he has yet to make it to the well and plans to check it on 3/30/16. Mr. Raber will contact myself with detailed plans by 4/1/16. |
0995651146 | 2013-11-15 | Production Wells | Violations Noted | My inspection found the well to be equipped with a plunger lift unit. The valves on the wellhead are closed. The wellhead is surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank and a mechanical separator. The flow line valve leading into the separator is closed. One side of the chain link fence that is surrounding the tank battery has been removed. The dike around the tank battery needs to be rebuilt. The proper identification is located on the tank battery. The lease road is in stable condition. Production records show the last year of reported production was in 2009. I will contact the company about the issues. The well shall be placed back into production in 90 days. If the well is not producible a plugging permit shall be obtained within 90 days and the well shall be plugged within 180 days of this compliance action. |
1343840507 | 2017-08-29 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection on this well. At the time of this inspection, the well was equipped with a plunger lift assembly and the annulus and flow line valves were open. The well was fenced. The tank battery consisted of one 100 BBL production tank and a mechanical separator. Valves on the separator have been opened and a chart was installed on the sales line which showed production, and was dated 8/28/2017. The tank battery dike has been rebuilt and the fence around the battery has been repaired. Proper, legible signage has been installed at the tank battery location. The lease access was stable. No violations observed. Compliance notice can be closed. |
1432748371 | 2015-05-28 | Production Wells | No Violations | My inspection found no changes since my last inspection. I contacted Ed Butler a Supervisor with Broad Street Energy and he stated instead of plugging the well the company is going to replace the flow line and get the well back into operation. He will notify me of the tentative date they will be performing the work on the well. |
1451317877 | 2015-12-28 | Production Wells | No Violations | My inspection found the well has changed owners from Broadstreet Energy to M&R Investments since my last inspection. The well is currently shut in due to a flow line leak. After walking the field there is no sign of contamination from the flow line. I was contacted by the landowner Barry Munson and was notified he does not want the well plugged and he would rather it be put back into production. I have contacted John Raver from M&R Investments and he will evaluate the well the first week of January. He stated that the company will fix the flow line and get the well back into production. I have advised him that the dike and the chain link fence needs to be repaired around the tank battery before the well is put back into production. |
1462296914 | 2016-05-03 | Production Wells | No Violations | My inspection found no changes to the location since my last inspection. I spoke with John from Circle M Well Services and he stated that they are scheduled to perform work on the flow line and the tank battery later on this month. |
146672319 | 2004-4-1 0:00:0 | PW | No Violations | |
1468606910 | 2016-07-11 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection on this well. The wellhead is equipped with a plunger lift unit and is surrounded by a chain link fence. The valves on the wellhead are open. The tank battery consists of a 100 BBL production tank and a mechanical separator. The flow line valve leading into the separator is closed. One side of the chain link fence that is surrounding the tank battery has been removed. The dike around the tank battery needs to be rebuilt. The proper identification is located on the tank battery. The lease road is in stable condition. I spoke with John Raber of M & R Investments and he indicated that new lines from the wellhead to the tank battery need to be installed and trenched through the adjacent farm field. He is awaiting landowner approval to install the line. |
1497280333 | 2017-06-12 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection for inspection report number 1468606910. The wellhead is equipped with a plunger lift unit and is surrounded by a chain link fence. The valves on the wellhead were closed but the flow line has been reattached to the tank battery production equipment. The tank battery consists of a 100 BBL production tank and a mechanical separator. The flow line valve leading into the separator is closed. The chain link fence that is surrounding the tank battery still needs repaired and the dike around the tank battery still needs rebuilt along the west side. The proper identification is located on the tank battery. The lease road is in stable condition. I spoke with John Raber of M & R Investments and he indicated that new lines from the well to the tank battery have been installed and connected, and the company will be back on site to complete the repairs to the tank battery and turn on the well. |
153914437 | 2014-8-18 0:00: | PW | No Violations | |
299921047 | 2003-3-11 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0995651146 | US-OH-131429 | 2014-02-27 | Well shall be plugged |
For data sources see[9]