34-055-20916

Well Details

Well ID: 34-055-20916
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Huntsburg Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: GIBBS
License Status: Producing
License Date: 1984-07-31
Spud Date: 1984-10-08
Spud Drilling Contractor: EDCO DRLG
Final Drill Date: 1984-10-12
Well Total Depth: 3967.00 ft
Configuration: Vertical
Latitude: 41.560000
Longitude: -81.060000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-07-31 254 EDCO DRILLING & PRODUCING GeoDate 7/31/84
Oil and Gas 1984-07-31 Issued Date 7/31/84 Expired Date 1/27/85 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03967 Proposed Drill Depth 03967
Original Spud 1984-10-08
Completed 1984-10-12
Reached Total Depth 1984-10-12
Completion Report Received 1984-11-07
Construction Permit Expires 1985-01-27
CO 1993-10-22 1111 MERIDIAN ENERGY COMPANY GeoDate 7/31/84
Change of Owner 2017-03-23 Operator changed from 1111, MERIDIAN ENERGY COMPANY to 1333, BIG SKY ENERGY INC - WELL TRANSFERRED TO BIG SKY FROM CHANGE OF OWNER FORM 7 DATED 2/1999 PER LEGAL EMAIL DATED 4/26/2016. INCORRECT WELL TRANSFERRED 34-007-2-0916-0000 CORRECT API #34-055-2-0916-0000 ON 3/23/2017 CM.
Record Last Modified 2017-03-23

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3852 3839 0
3852 3839 0
2006-09-11 3864 3924 23
3864 3924 23
3852 3839 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 500 Gal 0
H2O 0 1267 0 FRAC: H2O

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 WHITE J P 0.00 0.00 0
1986 WHITE J P 7528.00 312.00 365
1987 EDCO DRILLING & PRODUCING 267.00 252.00 365
1988 EDCO DRILLING & PRODUCING 3825.00 176.00 365
1989 EDCO DRILLING & PRODUCING 2197.00 98.00 365
1990 EDCO DRILLING & PRODUCING 1585.00 143.00 365
1991 EDCO DRILLING & PRODUCING 2687.00 202.00 365
1992 EDCO DRILLING & PRODUCING 981.00 152.00 365
1993 MERIDIAN ENERGY COMPANY 358.00 50.00 164
1994 MERIDIAN ENERGY COMPANY 2306.00 181.00 365
1995 MERIDIAN ENERGY COMPANY 1974.00 184.00 365
1996 MERIDIAN ENERGY COMPANY 1497.00 129.00 365
1997 MERIDIAN ENERGY COMPANY 677.00 28.00 365
1999 MERIDIAN ENERGY COMPANY 482.00 46.00 365
2000 MERIDIAN ENERGY COMPANY 216.00 49.00 365
2001 BIG SKY ENERGY INC 433.00 0.00 365
2002 MERIDIAN ENERGY COMPANY 174.00 58.00 365
2003 MERIDIAN ENERGY COMPANY 945.00 56.00 365
2004 MERIDIAN ENERGY COMPANY 475.00 33.00 365
2005 MERIDIAN ENERGY COMPANY 137.00 0.00 365
2006 MERIDIAN ENERGY COMPANY 15.00 0.00 365
2007 MERIDIAN ENERGY COMPANY 133.00 0.00 365
2008 MERIDIAN ENERGY COMPANY 1006.00 0.00 365
2009 MERIDIAN ENERGY COMPANY 113.00 0.00 365
2010 MERIDIAN ENERGY COMPANY 1026.00 0.00 365
2013 BIG SKY ENERGY INC 0.00 36.00 250
2014 BIG SKY ENERGY INC 0.00 0.00 250
2016 BIG SKY ENERGY INC 22.00 60.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 WHITE J P Brine 0 0
1986 WHITE J P Brine 717 365
1987 EDCO DRILLING & PRODUCING Brine 330 365
1988 EDCO DRILLING & PRODUCING Brine 279 365
1989 EDCO DRILLING & PRODUCING Brine 169 365
1990 EDCO DRILLING & PRODUCING Brine 148 365
1991 EDCO DRILLING & PRODUCING Brine 286 365
1992 EDCO DRILLING & PRODUCING Brine 103 365
1993 MERIDIAN ENERGY COMPANY Brine 65 164
1994 MERIDIAN ENERGY COMPANY Brine 236 365
1995 MERIDIAN ENERGY COMPANY Brine 275 365
1996 MERIDIAN ENERGY COMPANY Brine 48 365
1997 MERIDIAN ENERGY COMPANY Brine 78 365
1999 MERIDIAN ENERGY COMPANY Brine 0 365
2000 MERIDIAN ENERGY COMPANY Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 MERIDIAN ENERGY COMPANY Brine 0 365
2003 MERIDIAN ENERGY COMPANY Brine 0 365
2004 MERIDIAN ENERGY COMPANY Brine 0 365
2005 MERIDIAN ENERGY COMPANY Brine 0 365
2006 MERIDIAN ENERGY COMPANY Brine 0 365
2007 MERIDIAN ENERGY COMPANY Brine 0 365
2008 MERIDIAN ENERGY COMPANY Brine 0 365
2009 MERIDIAN ENERGY COMPANY Brine 0 365
2010 MERIDIAN ENERGY COMPANY Brine 0 365
2013 BIG SKY ENERGY INC Brine 0 250
2014 BIG SKY ENERGY INC Brine 0 250
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1044475280 2013-8-21 0:00: PW No Violations
-429214607 2018-3-2 0:00:0 PW No Violations
-926107201 2013-8-21 0:00: PW No Violations
0035345124 2012-05-10 Production Wells No Violations My inspection today found no change in the status of the plunger lift well. The tubing has not been repaired. The flow line is disconnected from the wellhead. Minor odor of gas coming from the tubing. No visible venting of gas. Operator has removed the 210 barrel production tank that was leaking. Operator partially cleaned up paraffin and free crude oil. Remaining free crude is locked up in the gravel. Called operator and left a message to contact me in regards to the status of the well and getting it back into production.
0429214607 2018-03-02 Production Wells No Violations I inspected this well pursuant to Chiefs Order #2017-17 issued for lack of insurance. The well and associated battery are located on an otherwise undeveloped, rural parcel At the time of this inspection, I noted the following: a wellhead with plunger-lift system in a clearing within a wooded and grassy area. The system was idle. The flow-line connections were closed. The access road to the well was heavily overgrown and rutted. The associated tank battery was comprised of one 100-barrel production tank, and horizontal separator, that is shared with the Gibbs #1 (#2-0917). The tank was empty, and the fittings and connections were in disrepair. The secondary containment was mostly overgrown with vegetation and covered with several inches of accumulated snow. There were no signs that the well was being produced.
0801023471 2016-02-04 Production Wells No Violations My inspection found the company has recently serviced the well. The valves on the wellhead are currently closed. The brush has been removed from the tank battery. The production tank has a oil coating on the side from swabbing the well into the tank. I contacted the well tender for the company about cleaning up the oil on the tank and updating the identification sign. He will also contact me if the wells get put back into production.
0926107201 2013-08-21 Production Wells No Violations Damaged tubing has been replaced. I new demco valve has been installed.
1044475280 2013-08-21 Production Wells No Violations My inspection found the wellhead was plumbed up from the tubing to the demco valve. The demco was closed and the rest of the wellhead had been disassembled. The tank battery consists of a 100 BBL production tank and a mechanical separator. There was no identification sign on location. There has been no production reported since 2010. I will contact the company about the issues.
1408023163 2014-08-14 Production Wells No Violations My inspection found no changes since my last inspection. The tank battery is over grown with vegetation and needs to be cleared out. The company is currently under chiefs order to stop operating in the state until they obtain the proper insurance. I will contact the company about the issues.
1989964865 2011-11-10 Production Wells Violations Noted Well is a rabbit well. Tubing below the Demco valve has a hole in it, the hole is half of the diameter of the tubing. Valves on the 4.5 inch casing are closed. Tubing was static only a slight odor of gas coming from the tubing. Spoke to Bob Barr on 11/14/2011, the well is shut in because they do not have the correct meter to flow gas into East Ohio lines. New meter is under construction. Tubing in this well has a salt ring, they have attempted to pull the tubing. They have put fresh water down the back side to attempt to free tubing. Tank battery is over grown with vegetation. The bottom of the 210Bbl production tank is leaking. There was standing free oil on the floor of the battery below the plumbing on the west side of tank. 100Bbl tank had oil staining on the floor of the battery under the valve. No oil outside of the dike. Will attempt to meet with work crew at another well to discuss needed repairs. Informed Bob of need repairs. Well needs the following: 1. Tubing repaired 2. Free oil and oil staining removed from tank battery 3. Vegetation cleared from tank battery. 4. Tanks repaired as need to contain oil and brine 5. Well put back into production or put into temporary inactive status 6. Identification sign posted at the tank battery and the wellhead. Picture of the well and tank battery taken this day.
35345124 2012-5-10 0:00: PW No Violations
801023471 2016-2-4 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1989964865 US-OH-120182 2014-06-27 Failure to legibly identify well
1989964865 US-OH-120183 2014-06-27 No SPCC dike/or failure to keep dike free of water or oil
1989964865 US-OH-120184 2014-06-27 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[9]

References