34-055-20920

Well Details

Well ID: 34-055-20920
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Huntsburg Township
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: MOTIL
License Status: Producing
License Date: 1984-08-02
Spud Date: 1984-08-28
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1984-09-02
Well Total Depth: 4090.00 ft
Configuration: Vertical
Latitude: 41.530000
Longitude: -81.060000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-08-02 Issued Date 8/2/84 Expired Date 1/29/85 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04090 Proposed Drill Depth 04090
Original Spud 1984-08-28
Completed 1984-09-02
Reached Total Depth 1984-09-02
Completion Report Received 1984-10-01
CO 1984-10-10 1530 CNG PRODUCING COMPANY GeoDate 8/2/84
Construction Permit Expires 1985-01-29
CO 1991-08-19 28 CGAS EXPLORATION,INC GeoDate 8/2/84
Change of Owner 2000-12-22 Operator changed from 28, CGAS EXPLORATION to 1966, PETROX INC
Change of Owner 2002-12-12 Operator changed from 1966, PETROX INC to 7033, BROAD STREET ENERGY COMPANY
Change of Owner 2007-09-26 Operator changed from 7033, BROAD STREET ENERGY COMPANY to 7276, SELECT ENERGY INVESTMENTS INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3874 3996 0
3874 3996 0
2006-09-11 3898 3978 27
3898 3978 27
3874 3996 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 500 Gal 70000 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 CNG PRODUCING COMPANY 9871.00 259.00 0
1985 CNG PRODUCING COMPANY 25467.00 826.00 365
1986 CNG PRODUCING COMPANY 8645.00 313.00 365
1988 CNG PRODUCING COMPANY 21992.00 70.00 365
1989 CNG PRODUCING COMPANY 2008.00 90.00 365
1990 CNG PRODUCING COMPANY 1315.00 0.00 365
1991 CGAS EXPLORATION 618.00 179.00 365
1992 CGAS EXPLORATION 1394.00 239.00 366
1993 CGAS EXPLORATION 1173.00 0.00 366
1994 CGAS EXPLORATION 1142.00 194.00 365
1995 CGAS EXPLORATION 1391.00 98.00 365
1996 CGAS EXPLORATION 1550.00 87.00 365
1997 CGAS EXPLORATION 1136.00 85.00 365
1998 CGAS EXPLORATION 854.00 89.00 365
1999 CGAS EXPLORATION 1106.00 0.00 365
2000 PETROX, INC 1349.00 0.00 90
2001 PETROX, INC 552.00 0.00 365
2002 BROAD STREET ENERGY COMPANY 25.00 0.00 28
2003 BROAD STREET ENERGY COMPANY 1012.00 44.00 365
2004 BROAD STREET ENERGY COMPANY 794.00 51.00 365
2005 BROAD STREET ENERGY COMPANY 763.00 103.00 365
2006 BROAD STREET ENERGY COMPANY 673.00 40.00 365
2007 BROAD STREET ENERGY COMPANY 651.00 123.00 365
2008 SELECT ENERGY INVESTMENTS INC 501.00 0.00 365
2009 SELECT ENERGY INVESTMENTS INC 370.00 0.00 365
2010 SELECT ENERGY INVESTMENTS INC 436.00 87.00 365
2011 SELECT ENERGY INVESTMENTS INC 495.00 86.00 365
2012 SELECT ENERGY INVESTMENTS INC 418.00 57.00 366
2013 SELECT ENERGY INVESTMENTS INC 308.00 0.00 365
2014 SELECT ENERGY INVESTMENTS INC 174.00 0.00 365
2015 SELECT ENERGY INVESTMENTS INC 293.00 0.00 365
2016 SELECT ENERGY INVESTMENTS INC 752.00 0.00 365
2017 SELECT ENERGY INVESTMENTS INC 366.00 53.00 365
2018 SELECT ENERGY INVESTMENTS INC 500.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 CNG PRODUCING COMPANY Brine 721 0
1985 CNG PRODUCING COMPANY Brine 690 365
1986 CNG PRODUCING COMPANY Brine 496 365
1988 CNG PRODUCING COMPANY Brine 85 365
1989 CNG PRODUCING COMPANY Brine 0 365
1990 CNG PRODUCING COMPANY Brine 0 365
1991 CGAS EXPLORATION Brine 73 365
1992 CGAS EXPLORATION Brine 214 366
1993 CGAS EXPLORATION Brine 88 366
1994 CGAS EXPLORATION Brine 223 365
1995 CGAS EXPLORATION Brine 191 365
1996 CGAS EXPLORATION Brine 75 365
1997 CGAS EXPLORATION Brine 67 365
1998 CGAS EXPLORATION Brine 183 365
1999 CGAS EXPLORATION Brine 119 365
2000 CGAS EXPLORATION Brine 0 365
2001 PETROX, INC Brine 0 365
2002 PETROX, INC Brine 55 364
2003 BROAD STREET ENERGY COMPANY Brine 18 365
2004 BROAD STREET ENERGY COMPANY Brine 33 365
2005 BROAD STREET ENERGY COMPANY Brine 121 365
2006 BROAD STREET ENERGY COMPANY Brine 0 365
2007 BROAD STREET ENERGY COMPANY Brine 69 365
2008 SELECT ENERGY INVESTMENTS INC Brine 0 365
2009 SELECT ENERGY INVESTMENTS INC Brine 30 365
2010 SELECT ENERGY INVESTMENTS INC Brine 55 365
2011 SELECT ENERGY INVESTMENTS INC Brine 108 365
2012 SELECT ENERGY INVESTMENTS INC Brine 66 366
2013 SELECT ENERGY INVESTMENTS INC Brine 0 365
2014 SELECT ENERGY INVESTMENTS INC Brine 0 365
2015 SELECT ENERGY INVESTMENTS INC Brine 365
2016 SELECT ENERGY INVESTMENTS INC Brine 365
2017 SELECT ENERGY INVESTMENTS INC Brine 7 365
2018 SELECT ENERGY INVESTMENTS INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-798833819 2012-4-23 0:00: PW No Violations
0798833819 2012-04-23 Production Wells No Violations I was on site today for a follow up inspection. The flowline leak, discovered on my previous inspection, has been repaired. The affected area from the repair has been graded. The operator has removed a 210 barrel production tank from the tank battery. This tank was no longer functional.
1280347970 2011-09-16 Production Wells No Violations Well is a Con-Coil well and is in production. Lease road is stable to the tank battery. Tank battery consists of two 100 barrel tanks, two 210barrel tanks and two mechincal separators. Permit 21074 shares this tank battery. Well and tank battery are in good repair. Identification sign was posted at the tank battery. Informed operator that an identification sign needs posted at the wellheads also. During inspection oil staining was located on the east side of the lease road, tank battery is located on the west side of the lease road. A depression was stained with oil and the affected area was 3 X 12. Contacted Operator in regards to oil staining and the Operators son, Rich, was on location within 10 minutes of the call. Rich stated that they had been working on the well due to decreased production. Rich reviewed the charts which showed abnormal production. Oil staining was from a flow line leak. Well was shut in. Oil staining will be remediated. Line will be repaired.

For data sources see[9]