X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21607

Well Details

Well ID: 34-055-21607
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Burton Township
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: KAUFMAN B & J
License Status: Producing
License Date: 1989-08-10
Spud Date: 1989-11-02
Spud Drilling Contractor: [[EPC [EASTERN PETROLEUM]]]
Final Drill Date: 1989-11-09
Well Total Depth: 4078.00 ft
Configuration: Vertical
Latitude: 41.460000
Longitude: -81.190000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1989-08-10 Issued Date 8/10/89 Expired Date 8/10/90 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04078 Proposed Drill Depth 04078
Original Spud 1989-11-03
Completed 1989-11-09
Reached Total Depth 1989-11-09
Completion Report Received 1990-01-24
CO 1990-02-06 773 FORTUNE GAS & OIL GeoDate 8/10/89
Construction Permit Expires 1990-08-10
Change of Owner 2002-06-11 Operator changed from 773, FORTUNE GAS & OIL to 4939, ENERGY RESOURCES AMERICA
Change of Owner 2003-10-06 Operator changed from 4939, ENERGY RESOURCES AMERICA to 7525, J & T EXPLORATION LLC
Change of Owner 2015-02-11 Operator changed from 7525, J & T EXPLORATION LLC to 935, BOCOR HOLDINGS, LLC/BOCOR PROD
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3873 3875 28
3868 3968 0
1997-06-29 3868 3968 0
0 16
0 16
2006-09-11 0 16
2006-09-11 3913 3928 6
2006-09-11 3890 3900 3
2006-09-11 3883 3885 3

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 70000 Gal 50000 FRAC:WATER/SAND/ACID
ACID 0 500 Gal 0 FE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1990 FORTUNE GAS & OIL 15007.00 671.00 328
1991 FORTUNE GAS & OIL 5608.00 293.00 365
1992 FORTUNE GAS & OIL 3788.00 146.00 365
1993 FORTUNE GAS & OIL 3021.00 247.00 365
1994 FORTUNE GAS & OIL 3904.00 191.00 365
1995 FORTUNE GAS & OIL 2901.00 47.00 365
1996 FORTUNE GAS & OIL 1069.00 92.00 365
1997 FORTUNE GAS & OIL 809.00 0.00 365
1998 FORTUNE GAS & OIL 1011.00 0.00 365
1999 FORTUNE GAS & OIL 534.00 0.00 365
0 0 0
2000 FORTUNE GAS & OIL 400.00 88.00 365
2001 FORTUNE GAS & OIL 752.00 124.00 365
2002 FORTUNE GAS & OIL 75.00 0.00 59
2006 J & T EXPLORATION LLC 869.00 54.00 365
2007 J & T EXPLORATION LLC 980.00 75.00 0
2008 J & T EXPLORATION LLC 802.00 72.00 0
2009 J & T EXPLORATION LLC 633.00 79.00 0
2010 J & T EXPLORATION LLC 864.00 14.00 0
2011 J & T EXPLORATION LLC 731.00 35.00 0
2015 BOCOR HOLDINGS, LLC 155.00 32.00 133
2016 BOCOR HOLDINGS, LLC 3350.00 18.00 365
2017 BOCOR HOLDINGS, LLC 5796.00 102.00 365
2018 BOCOR HOLDINGS, LLC 1618.00 66.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1990 FORTUNE GAS & OIL Brine 0 328
1991 FORTUNE GAS & OIL Brine 0 365
1992 FORTUNE GAS & OIL Brine 0 365
1993 FORTUNE GAS & OIL Brine 0 365
1994 FORTUNE GAS & OIL Brine 0 365
1995 FORTUNE GAS & OIL Brine 0 365
1996 FORTUNE GAS & OIL Brine 0 365
1997 FORTUNE GAS & OIL Brine 0 365
1998 FORTUNE GAS & OIL Brine 0 365
1999 FORTUNE GAS & OIL Brine 0 365
2000 FORTUNE GAS & OIL Brine 0 365
2001 FORTUNE GAS & OIL Brine 0 365
2002 FORTUNE GAS & OIL Brine 0 59
2006 J & T EXPLORATION LLC Brine 0 365
2007 J & T EXPLORATION LLC Brine 0 0
2008 J & T EXPLORATION LLC Brine 0 0
2009 J & T EXPLORATION LLC Brine 0 0
2010 J & T EXPLORATION LLC Brine 0 0
2011 J & T EXPLORATION LLC Brine 0 0
2015 BOCOR HOLDINGS, LLC Brine 0 133
2016 BOCOR HOLDINGS, LLC Brine 68 365
2017 BOCOR HOLDINGS, LLC Brine 148 365
2018 BOCOR HOLDINGS, LLC Brine 40 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1415238680 2007-9-24 0:00: PW No Violations
-71049254 2014-8-7 0:00:0 PW No Violations
0071049254 2014-08-07 Production Wells No Violations My inspection today found no changes since my last inspection.
0144977718 2015-04-07 Production Wells No Violations The sale of J&T Exploration to Bocor Holdings LLC was completed on 2/11/2015. J&T Exploration had a compliance notice on this well for not reporting annual production. The compliance notice can be lifted now that the well is under new ownership.
0580507237 2013-07-16 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The well and tank battery are in good repair. The tank battery consists a 210 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition. The production of this well has not been reported for 2012. I spoke with the well tender Jim about the issue. The company contact information is not valid.
1179761052 2007-05-21 Production Wells No Violations One 110 BBL and one 210 BBL tank on site, mechanical separator. Well head is just north of the shop building. 210 tank has over flowed. There is oil down the side of the tank. Oil on the ground around the tank. Oil is contained within he dike.
1239718071 2009-04-14 Production Wells No Violations Well head is in good repair. Tank battery dike as been repaired. Small spill of oil under the separator, approximately 1/2 gallon of crude. Called number on tank battery left message to clean up spill and return call. Crude is contained in the battery. No chance of the small amount leaving battery. Requested that peat sorb be mixed into crude.
1324031837 2015-05-28 Production Wells No Violations My inspection found the company has installed a new sales line from the tank battery to the meter station. The dike around the tank battery has been rebuilt. No other changes to the location since my last inspection.
1411559462 2014-09-23 Production Wells Violations Noted

--

1415238680 2007-09-24 Production Wells No Violations Well head is in good repair. There is a small oil spill in the tank battery below the clean out valve. It appears that a gallon or less of oil was spilled when operator was draining the tank. I called J&T and asked that they add some peat or peat dry to the spill to help break down the oil. The 210 bbl tank has over flowed in the past. Operator informed me that they tank had, had a bad riser pipe on it. The pipe has been repaired.
1418311002 2014-12-11 Production Wells No Violations My inspection found the contaminated stone and soil has been removed. The well has been repaired and is currently shut in. No other changes to the well since my last inspection.
1442847535 2015-09-17 UrbanProduction Wells No Violations I was on location for the clean up of the tank battery. The company has hired Canton Oil Well Services to perform the clean up. They have removed both the 100 BBL and the 210 BBL tanks from inside the tank battery and plan on removing them from the location. They will replace both tanks with a new 100 BBL production tank. The company has stacked all of the oil contaminated stone and soil on a liner next to the lease road until a container arrives to remove it from the location. The company is currently in the process of building a new containment dike for the production tank with a liner installed under the stone base. I will check back on 9/18/2015 to see if the oil contaminated stone has been removed from the location.
144977718 2015-4-7 0:00:0 PW No Violations
1454682214 2016-02-04 UrbanProduction Wells No Violations My inspection found the company has installed a new 100 BBL production tank. The 210 BBL production tank and the 100 BBL brine tank are sitting on the lease road. I contacted Tom Huffman, the well tender for Bocor about having the tanks hauled away. The well was placed back into production. No other changes to the location since my last inspection.
1462829380 2015-09-18 UrbanProduction Wells No Violations My inspection found the oil contaminated soil and stone has been removed from the location. The new dike for the tank battery is lined and completed. The new tank will not be installed until the week of 9/21/2015. The well is shut in until the new production tank arrives. The 210 BBL production tank and the 100 BBL brine tank are set off to the side of the lease road and are due to be hauled off location by Canton Oil Well Services the week of 9/21/2015.
1650807970 2015-09-16 Production Wells Violations Noted My inspection found a hole that is 3 ft above the base of the tank was actively leaking oil and brine from the tank. Bocor hired a company to flip and repair the 210 BBL production tank and 100 BBL brine tanks two weeks prior to this incident. There is oil saturated stone that is 2 ft by 5 ft next to the base of the tank. After further investigation I noticed the base stone to the East of the tank, inside the tank battery, was saturated with oil. On the North side of the tank battery the is evidence of oil and brine making it through the sandy soil used for the containment dike and making it 50 ft down the hill heading East of the tank battery. Tom Huffman from Bocor is on location and is currently having a vac truck empty both tanks. The company will have an excavator on location to remove the 210 BBL production tank by the end of the day. A container will be on location in the morning and the company will remove all saturated stone and soil from the affected areas and replaced with new. I will be on location 9/17/2015 to observe the clean up.
580507237 2013-7-16 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1411559462 US-OH-112107 2014-10-14 Well operation causing pollution and contamination
1411559462 US-OH-112108 2014-10-14 General Safety
1411559462 US-OH-112109 2014-10-14 Well insufficiently equipped to prevent escape of oil and gas
1411559462 US-OH-112110 2014-10-14 Defective casing, leaking well
1411559462 US-OH-112111 2014-10-14 Statement of annual production not filed
1650807970 US-OH-116284 2015-11-25 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]

References