34-055-21706

Well Details

Well ID: 34-055-21706
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: MOROCCO UNIT
License Status: Producing
License Date: 1991-07-19
Spud Date: 1991-08-05
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1991-08-08
Well Total Depth: 3665.00 ft
Configuration: Vertical
Latitude: 41.550000
Longitude: -81.380000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1991-07-19 18 MUTUAL OIL & GAS CO GeoDate 7/19/91
Oil and Gas 1991-07-19 Issued Date 7/19/91 Expired Date 7/18/92 Acres 0020581 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03665 Proposed Drill Depth 03665
Original Spud 1991-08-05
Completed 1991-08-08
Reached Total Depth 1991-08-08
Completion Report Received 1991-09-09
Construction Permit Expires 1992-07-18
Change of Owner 2000-09-08 Operator changed from 18, MUTUAL OIL & GAS CO to 6288, ALLIANCE PETROLEUM CORPORATION
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3478 3564 0
3478 3564 0
2006-09-11 3522 3541 14
3522 3541 14
3478 3564 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1400 Bbl 55000 FRAC W/1400 BW & 550 SX SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1991 MUTUAL OIL & GAS CO 2109.00 0.00 47
1992 MUTUAL OIL & GAS CO 25229.00 396.00 365
1993 MUTUAL OIL & GAS CO 23709.00 466.00 365
1994 MUTUAL OIL & GAS CO 15982.00 274.00 365
1995 MUTUAL OIL & GAS CO 20240.00 370.00 365
1996 MUTUAL OIL & GAS CO 23976.00 422.00 365
1997 MUTUAL OIL & GAS CO 27741.00 359.00 365
1998 MUTUAL OIL & GAS CO 20035.00 224.00 365
2000 OHIO L & M CO INC 11813.00 118.00 365
2001 OHIO L & M CO INC 25969.00 285.00 365
2002 OHIO L & M CO INC 24124.00 164.00 365
2003 OHIO L & M CO INC 19762.00 82.00 365
2004 OHIO L & M CO INC 20357.00 162.00 365
2005 OHIO L & M CO INC 30557.00 145.00 365
2006 ALLIANCE PETROLEUM CORPORATION 22069.00 0.00 365
2007 ALLIANCE PETROLEUM CORPORATION 25612.00 144.00 365
2008 ALLIANCE PETROLEUM CORPORATION 7775.00 0.00 365
2009 ALLIANCE PETROLEUM CORPORATION 5955.00 0.00 365
2010 ALLIANCE PETROLEUM CORPORATION 7570.00 0.00 365
2011 ALLIANCE PETROLEUM CORPORATION 3954.00 0.00 365
2012 ALLIANCE PETROLEUM CORPORATION 2493.00 41.00 366
2013 ALLIANCE PETROLEUM CORPORATION 1870.00 0.00 365
2014 ALLIANCE PETROLEUM CORPORATION 1678.00 0.00 365
2015 ALLIANCE PETROLEUM CORPORATION 1019.00 0.00 365
2016 ALLIANCE PETROLEUM CORPORATION 1308.00 0.00 365
2017 ALLIANCE PETROLEUM CORPORATION 794.00 0.00 365
2018 ALLIANCE PETROLEUM CORPORATION 1195.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1991 MUTUAL OIL & GAS CO Brine 0 47
1992 MUTUAL OIL & GAS CO Brine 16 365
1993 MUTUAL OIL & GAS CO Brine 1 365
1994 MUTUAL OIL & GAS CO Brine 3 365
1995 MUTUAL OIL & GAS CO Brine 0 365
1996 MUTUAL OIL & GAS CO Brine 0 365
1997 MUTUAL OIL & GAS CO Brine 0 365
1998 MUTUAL OIL & GAS CO Brine 15 365
2000 OHIO L & M CO INC Brine 0 365
2001 OHIO L & M CO INC Brine 0 365
2002 OHIO L & M CO INC Brine 0 365
2003 OHIO L & M CO INC Brine 0 365
2004 OHIO L & M CO INC Brine 0 365
2005 OHIO L & M CO INC Brine 0 365
2006 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2015 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2016 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2017 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2018 ALLIANCE PETROLEUM CORPORATION Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1439142305 2013-6-18 0:00: UP No Violations
-742967244 2017-9-7 0:00:0 UP No Violations
0000008395 Preliminary Restoration No Violations PASSED Y WITNESSED 6/3/93 INSPECTOR HAROLD MORAVY DATE 06/0319/93 DATA FROM OLD VAX INFO
0742967244 2017-09-07 UrbanProduction Wells No Violations I conducted a followup inspection regarding locking the tank battery man door. At the time of this inspection, a lock was installed on the tank battery man door. No other violations were observed.
1439142305 2013-06-18 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The well and tank battery are in good repair and are surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 25 BBL poly brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.
1517639343 2017-03-07 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with plunger lift assembly and the valves on the wellhead were open. The well was fenced with a locked man door. The reported production for this well is current. The tank battery consisted of one 100 BBL production tank, one 25 BBL poly brine tank and a mechanical separator. Valves on the separator were open and the chart dated 2/28/17 showed production. There was a domestic line with a meter, drip bottle and regulator plumbed off of the separator. The production tank valves were equipped with flat plugs. The tank battery was diked and fenced with a locked man door. Proper, legible signage was located at the well and tank battery. The lease access was good. No violations observed.
2119215040 2018-07-18 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with plunger lift assembly and the gate valve on the tubing was closed. The 2 inch flow line valve was open. The well was fenced with a locked man door. Reported production for this well was current. The tank battery consisted of one 100 BBL production tank, one 25 BBL poly brine tank and a mechanical separator. Valves on the separator were open and the chart dated 7/16/18 showed production. There was a domestic line with a meter, drip bottle and regulator plumbed off of the separator. The production tank valves were equipped with flat plugs and locks. The tank battery was diked and fenced with a locked man door. Proper, legible signage was located at the well and tank battery. Lease access was stable. No violations observed.
8395 PL No Violations