34-055-21741

Well Details

Well ID: 34-055-21741
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: CHRIST PRESBYTERIAN CHURCH UNIT
License Status: Producing
License Date: 1992-05-26
Spud Date: 1992-11-28
Spud Drilling Contractor: MOHAWK DRLG
Final Drill Date: 1992-12-02
Well Total Depth: 3955.00 ft
Configuration: Vertical
Latitude: 41.530000
Longitude: -81.330000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1992-05-26 3442 CUTTER EXPLORATION INC GeoDate 5/26/92
Oil and Gas 1992-05-26 Issued Date 5/26/92 Expired Date 5/26/93 Acres 0022000 Tool Type CRAF Proposed Formation CLINTON Proposed Depth Proposed Drill Depth
Original Spud 1992-11-28 PERMIT EXPIRED.
Completed 1992-12-02 PERMIT EXPIRED.
Reached Total Depth 1992-12-02 PERMIT EXPIRED.
Construction Permit Expires 1993-05-26 PERMIT EXPIRED.
Completion Report Received 2006-07-24 PERMIT EXPIRED.
Record Last Modified 2017-02-15 PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-28 3758 3786 27
3758 3786 27
3758 3786 27

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1800 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 CUTTER EXPLORATION INC 4820.00 75.00 180
1994 CUTTER EXPLORATION INC 26105.00 316.00 365
1995 CUTTER EXPLORATION INC 55972.00 436.00 365
1996 CUTTER EXPLORATION INC 39092.00 230.00 365
1997 CUTTER EXPLORATION INC 26583.00 158.00 365
1998 CUTTER EXPLORATION INC 22819.00 155.00 365
1999 CUTTER EXPLORATION INC 25277.00 172.00 365
2000 CUTTER EXPLORATION INC 23625.00 118.00 365
2001 CUTTER EXPLORATION INC 27195.00 156.00 365
2002 CUTTER EXPLORATION INC 25809.00 155.00 365
2003 CUTTER EXPLORATION INC 30024.00 108.00 365
2004 CUTTER EXPLORATION INC 17978.00 46.00 365
2005 CUTTER EXPLORATION INC 18956.00 0.00 365
2006 CUTTER EXPLORATION INC 13834.00 0.00 365
2008 CUTTER EXPLORATION INC 14182.00 207.00 365
2009 CUTTER EXPLORATION INC 23195.00 135.00 365
2010 CUTTER EXPLORATION INC 19101.00 49.00 365
2011 CUTTER EXPLORATION INC 13955.00 0.00 0
2012 CUTTER EXPLORATION INC 5317.00 53.00 366
2013 CUTTER EXPLORATION INC 8409.00 0.00 365
2014 CUTTER EXPLORATION INC 7267.00 0.00 365
2015 CUTTER EXPLORATION INC 3895.00 0.00 365
2016 CUTTER EXPLORATION INC 4875.00 16.00 365
2017 CUTTER EXPLORATION INC 0.00 2383.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 CUTTER EXPLORATION INC Brine 13 180
1994 CUTTER EXPLORATION INC Brine 210 365
1995 CUTTER EXPLORATION INC Brine 145 365
1996 CUTTER EXPLORATION INC Brine 60 365
1997 CUTTER EXPLORATION INC Brine 0 365
1998 CUTTER EXPLORATION INC Brine 50 365
1999 CUTTER EXPLORATION INC Brine 70 365
2000 CUTTER EXPLORATION INC Brine 65 365
2001 CUTTER EXPLORATION INC Brine 120 365
2002 CUTTER EXPLORATION INC Brine 130 365
2003 CUTTER EXPLORATION INC Brine 106 365
2004 CUTTER EXPLORATION INC Brine 106 365
2005 CUTTER EXPLORATION INC Brine 0 365
2006 CUTTER EXPLORATION INC Brine 0 365
2008 CUTTER EXPLORATION INC Brine 0 365
2009 CUTTER EXPLORATION INC Brine 178 365
2010 CUTTER EXPLORATION INC Brine 110 365
2011 CUTTER EXPLORATION INC Brine 75
2012 CUTTER EXPLORATION INC Brine 20 366
2013 CUTTER EXPLORATION INC Brine 0 365
2014 CUTTER EXPLORATION INC Brine 80 365
2015 CUTTER EXPLORATION INC Brine 0 365
2016 CUTTER EXPLORATION INC Brine 75 365
2017 CUTTER EXPLORATION INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1277981503 2016-10-19 0:00 UP No Violations
-1815846786 2006-6-29 0:00: PW No Violations
0508302226 2007-03-12 Production Wells No Violations Well is fenced and no leaks. Lock on the gate not being used. Tank Battery two 110 BBL tanks and on 50 BBL tank on site. Dike needs repaired. Two separators one site, one mechanical and one heated. Gates on the tank battery not locked.
0894029075 2013-06-12 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The fence around the wellhead needs repaired and secured with a lock. The tank battery is in good repair. The tank battery consists of two 100 BBL production tanks, a 50 BBL brine tank, and two mechanical separators. The production tank is vented into a 55 gallon charcoal filter and then up to a spark arrestor. The well and the tank battery need identification signs. The lease road is in good condition.
1254400845 2016-07-25 UrbanProduction Wells No Violations I conducted an inspection on this well. The well is equipped with a plunger lift unit and the valves on the wellhead were open. There was an audible leak on the well two inch flow line at the hammer union. There was a domestic line with meter and drip bottle plumbed off of the 4.5 inch casing. The well was fenced but needed a new lock on the man door. The tank battery consisted of two, 100 BBL production tanks, one, 50 BBL steel brine tank, a mechanical separator, and a heater treater separator. The tank battery was diked, however an animal burrow had been made and breached the dike from both sides. It will need filled and repaired. The tank battery was fenced and the man door needs a new lock. The signage needs to be updated to include the correct well information. I contacted Mark Turpak from Cutter and addressed the leak at the well, new signage at the tank battery, lock for the man door and repairing the dike.
1277981503 2016-10-19 UrbanProduction Wells No Violations I conducted a follow-up inspection on this well from the previous inspection conducted on 7/25/2016. The well is equipped with a plunger lift unit and the valves on the wellhead were open. There was an audible leak on the well two inch flow line at the hammer union, which has been repaired. There was a domestic line with meter and drip bottle plumbed off of the 4.5 inch casing. The well was fenced but needed a new lock on the man door. The tank battery consisted of two, 100 BBL production tanks, one, 50 BBL steel brine tank, a mechanical separator, and a heater treater separator. The tank battery was diked, however an animal burrow had been made and breached the dike from both sides. At the time of this inspection, it was observed that the dike has been repaired and the man door at the tank battery has a new lock installed. The signage needed updated to include the correct well information and has been changed to reflect current owner information. I contacted Mark Turpak from Cutter to address the need for a lock on the man door at the well location.
1815846786 2006-06-29 Production Wells No Violations No violation found tank battery will have to up grade to HB278 RULES
508302226 2007-3-12 0:00: PW No Violations
894029075 2013-6-12 0:00: UP No Violations

For data sources see[9]