If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-055-21784 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.61,"lon":-81.17,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Hambden Township | |
Operator Name: DANNY LONG & SONS INC | |
Well Pad ID: | |
Farm/Lease Name: BIG CREEK PROPERTIES | |
License Status: Producing | |
License Date: 2019-03-25 | |
Spud Date: 2002-04-30 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2002-05-04 | |
Well Total Depth: 3910.00 ft | |
Configuration: Vertical | |
Latitude: 41.610000 | |
Longitude: -81.170000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2002-01-22 | Proposed Formations:ORISKANY/CLINTON, Issued Date:1/22/2002, Expired Date:1/22/2003 6:00:00 AM, Drilling unit acres:41.068, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2002-04-30 | RBDMS Rec |
Completed | 2002-05-04 | RBDMS Rec |
Reached Total Depth | 2002-05-04 | RBDMS Rec |
Completion Report Received | 2002-08-15 | RBDMS Rec |
Change of Owner | 2002-09-20 | Operator changed from 2386, EXCALIBUR EXPLORATION INC to 3442, CUTTER EXPLORATION INC |
APP | 2006-11-17 | Proposed Formations:CLINTON, Issued Date:11/17/2006, Expired Date:11/17/2007 6:00:00 AM, Drilling unit acres:41.068, Proposed Well Type:OG, Proposed Well Class: |
Change of Owner | 2013-08-16 | Operator changed from 3442, CUTTER EXPLORATION INC to 3606, LONG DANNY L & SONS |
APP | 2019-03-25 | Proposed Formations:CLINTON, Issued Date:3/25/2019, Expired Date:3/24/2021 12:00:00 PM, Drilling unit acres:41.068, Proposed Well Type:OG, Proposed Well Class: |
Record Last Modified | 2019-04-01 | RBDMS Rec |
Construction Permit Expires | 2021-03-24 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2002-09-24 | 3722 | 3748 | 21 |
3722 | 3748 | 21 | |
3722 | 3748 | 21 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 77000 Gal | 25000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2003 | CUTTER EXPLORATION INC | 774.00 | 0.00 | 0 |
2004 | CUTTER EXPLORATION INC | 208.00 | 0.00 | 365 |
2005 | CUTTER EXPLORATION INC | 191.00 | 35.00 | 365 |
2006 | CUTTER EXPLORATION INC | 342.00 | 0.00 | 365 |
2014 | DANNY LONG & SONS INC | 0.00 | 0.00 | 0 |
2015 | DANNY LONG & SONS INC | 0.00 | 0.00 | 0 |
2016 | DANNY LONG & SONS INC | 0.00 | 0.00 | 0 |
2017 | DANNY LONG & SONS INC | 0.00 | 0.00 | 0 |
2018 | DANNY LONG & SONS INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2003 | CUTTER EXPLORATION INC | Brine | 299 | |
2004 | CUTTER EXPLORATION INC | Brine | 248 | 365 |
2005 | CUTTER EXPLORATION INC | Brine | 250 | 365 |
2006 | CUTTER EXPLORATION INC | Brine | 189 | 365 |
2014 | DANNY LONG & SONS INC | Brine | 0 | 0 |
2015 | DANNY LONG & SONS INC | Brine | 0 | 0 |
2016 | DANNY LONG & SONS INC | Brine | 0 | 0 |
2017 | DANNY LONG & SONS INC | Brine | 0 | 0 |
2018 | DANNY LONG & SONS INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1203313042 | 2018-10-17 0:00 | PW | No Violations | |
-389625179 | 2017-6-30 0:00: | PW | No Violations | |
-476032822 | 2014-1-13 0:00: | PW | No Violations | |
-8133557 | 2017-10-17 0:00 | PW | No Violations | |
0008133557 | 2017-10-17 | Production Wells | No Violations | I conducted an inspection on this well. Vegetative maintenace has been conducted at the well and tank battery locations, since my last inspection on 6/30/2017. The annulus and flow line valves were still closed on the wellhead. Production records for this well have not met production requirements since 2006. The tank battery consisted of one 100 BBL production tank, one 100 BBL brine tank and a mechanical separator. Valves on the separator were open. The tank battery was diked and had legible signage. The lease access was stable. I contacted Danny L. Long and Sons, and spoke with Virginia Long (330-866-3558). She informed me that the company was still trying to sell the well at this current time. As requested per the phone coversation with Virginia Long, the company will submit within 30 days of this report, a timeline of when the well is going to be sold or put back into production. |
0130915213 | 2013-08-07 | Production Wells | No Violations | My inspection found the well to be equipped with a plunger lift unit. The valves on the well are shut in. There has not been production since 2006. The well and tank battery are over grown with weeds. The tank battery consists of a 100 BBL production tank, a 100 BBL brine tank, and a mechanical separator. There is no identification on the tank battery. The lease road is in stable condition. Mike Cutter is in the process of selling the well. |
0389625179 | 2017-06-30 | Production Wells | No Violations | I conducted this requested inspection for landowner Keith Kornell. Mr. Kornell is looking to sell his property that the tank battery is located on and wanted to know what the status of the well was. Production records for this well have not met production requirements since 2006. This well was equipped with a plunger lift assembly and the valves on the wellhead were closed. The pressure gauge on the tubing read 900 psi. The well was overgrown with brush. The tank battery consisted of one 100 BBL production tank, one 100 BBL brine tank and a mechanical separator. Valves on the separator were open. The tank battery was diked and had legible signage. The lease access was stable. I contacted Danny L. Long and Sons, and spoke with Barbara Long. She informed me that the company was trying to sell the well at this current time. I contacted the landowner Keith Kornell to inform him of the companys plans to sell the well. |
0476032822 | 2014-01-13 | Production Wells | No Violations | My inspection found that Mike Cutter has sold the well to Danny Long. The vegetation has been removed from the tank battery and from around the well. There are new guages on the well and the separator. The company is in the process of getting the well back into production. The proper identification is on the tank battery. No violations found. |
1203313042 | 2018-10-17 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1532959632. At the time of this inspection, the well has not been plugged or in production. No plugging permit for this well has been obtained by the company at this time. The well was equipped with a plunger lift assembly and the gate valve on the tubing was closed. The 2 inch flow line valve was closed. The tank battery and well location had vegetative maintenance conducted. The identification located at the tank battery has been updated to reflect the current owner information.
Danny Long & Sons, Inc. still needs to: 1) Plug the well. |
130915213 | 2013-8-7 0:00:0 | PW | No Violations | |
1532959632 | 2018-07-30 | Production Wells | Violations Noted | I conducted an inspection on this well. In previous discussions with Virginia Long of Danny Long & Sons, LLC, Ms. Long had stated that the company was trying to sell the well, or put the well back into production. This information was included in the last inspection report dated 10/17/2017. As requested by ODNR-DOGRM, Ms Long had sent a letter of intent dated 11/13/2017 addressing the above information pertaining to the well. At the time of this inspection, the well was equipped with a plunger lift assembly and the gate valve on the tubing was closed. The 2 inch flow line valve off of the tubing was closed. The well was overgrown with brush. Production for this well has been submitted as zero since 2014. The tank battery consisted of one 100 BBL production tank, one 100 BBL brine tank and a mechanical separator. Valves on the separator were open. The tank battery was diked and had legible signage. The tank battery was overgrown with small trees and brush. The lease access was stable. I contacted Danny L. Long and Sons, and spoke with Virginia Long on 7/30/2018. She informed me that the company was still trying to sell the well at this current time. The well shall be plugged. The well owner operator shall also submit a written plugging schedule to inspector Shannon Mullins at 3575 Forest Lake Drive, Suite 150, Uniontown, OH 44685 /within 30 days. Per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging is approved or denied. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1532959632 | US-OH-114735 | 2018-07-31 | NONE | Well shall be plugged |
For data sources see[9]