X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21792

Well Details

Well ID: 34-055-21792
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Middlefield Township
Operator Name: DAVID R HILL INC
Well Pad ID:
Farm/Lease Name: MILLER MOSE UNIT
License Status: Producing
License Date: 2004-05-04
Spud Date: 2004-07-04
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2004-07-08
Well Total Depth: 4160.00 ft
Configuration: Vertical
Latitude: 41.460000
Longitude: -81.020000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-05-04 Proposed Formations:CLINTON, Issued Date:5/4/2004, Expired Date:5/4/2005 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2004-06-18 CORRECTION TO FOOTAGE : SHOULD BE 720'SL & 2050'EL OF LOT 24.
Original Spud 2004-07-04 RBDMS Rec
Completed 2004-07-08 RBDMS Rec
Reached Total Depth 2004-07-08 RBDMS Rec
Completion Report Received 2004-11-05 RBDMS Rec
Construction Permit Expires 2005-05-04 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-12-15 3947 4016 61
3947 4016 61
3947 4016 61

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2000 Bbl 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 DAVID R HILL INC 300.00 80.00 133
2005 DAVID R HILL INC 5539.00 628.00 365
2006 DAVID R HILL INC 4146.00 302.00 365
2007 DAVID R HILL INC 2436.00 290.00 365
2008 DAVID R HILL INC 2433.00 178.00 365
2009 DAVID R HILL INC 2226.00 204.00 365
2010 DAVID R HILL INC 1941.00 186.00 365
2011 DAVID R HILL INC 1538.00 100.00 365
2012 DAVID R HILL INC 1330.00 108.00 366
2013 DAVID R HILL INC 1249.00 120.00 365
2014 DAVID R HILL INC 339.00 35.00 365
2015 DAVID R HILL INC 101.00 83.00 365
2016 DAVID R HILL INC 1509.00 79.00 365
2017 DAVID R HILL INC 72.00 0.00 365
2018 DAVID R HILL INC 562.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 DAVID R HILL INC Brine 144 133
2005 DAVID R HILL INC Brine 252 365
2006 DAVID R HILL INC Brine 116 365
2007 DAVID R HILL INC Brine 148 365
2008 DAVID R HILL INC Brine 100 365
2009 DAVID R HILL INC Brine 141 365
2010 DAVID R HILL INC Brine 70 365
2011 DAVID R HILL INC Brine 88 365
2012 DAVID R HILL INC Brine 43 366
2013 DAVID R HILL INC Brine 53 365
2014 DAVID R HILL INC Brine 40 365
2015 DAVID R HILL INC Brine 72 365
2016 DAVID R HILL INC Brine 0 365
2017 DAVID R HILL INC Brine 0 365
2018 DAVID R HILL INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1136368793 2015-4-6 0:00:0 PW No Violations
-47005016 2008-12-3 0:00: PW No Violations
-976768831 2009-3-24 0:00: PL No Violations
0047005016 2008-12-03 Production Wells Violations Noted Well is a rabbit well. Tank battery dike is in good repair. Two 100BBL tank in battery. There is 3 feet between the two tanks. There 6 2 between the production tank and the mechanical separator. Called Don Craiger requested that the tank either be moved or the separator be spaced correctly. Verbal NOV given please fix in 30days. Called Gary the pumper for David Hill, both tanks are production tanks. Spacing needs corrected between the separator and the production tank. Space at this time is 6 feet, safety rules call for 10 feet.
0976768831 2009-03-24 Preliminary Restoration No Violations Spacing between the separator and the tanks has not been corrected.
1136368793 2015-04-06 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open. The well and the tank battery are in good repair. The tank battery consists of a 100 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The 100 BBL brine tank is showing signs of leaking from the heater port at the base of the tank. The proper identification is located on the tank battery. The lease road is in stable condition. I left a message for Mr. Hill of David R. Hill Inc. about having the tank removed or repaired.
1442182856 2018-02-06 Production Wells No Violations During this inspection, the well was observed to be equipped with a plunger lift assembly and the annulus and flow line valves were open. The well was fenced. Production records for this well were current. The tank battery consisted of one 100 BBL production tank, one 100 BBL brine tank and a mechanical separator. Valves on the separator were open. The tank battery was diked with legible signage. The lease access was stable. No violations observed.
1831735109 2009-12-07 Production Wells No Violations Separator spacing has not been corrected. Ive spoken to Don Craiger from Hill David R Inc regarding the spacing of the separator and the tank, Don stated that they are using that tank for brine, not production. Ive had two additional newer wells in Geauga County with spacing issues, from different companies. Companies where both given warnings and allowed to produce by supervisor. Same courtesy will be given to this company, once. There was oil staining on the ground below the tank valve to the tank that is a Brine tank. Thief hatches where secured. Tank battery dike is in good repair. Identification sign is correct.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0047005016 US-OH-125092 2008-12-03 Violation of tank spacing requirements

For data sources see[9]