Well ID: 34-055-21798 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.47,"lon":-81.25,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Newbury Township | |
Operator Name: ROCKEFELLER OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: HESS | |
License Status: Producing | |
License Date: 2004-08-09 | |
Spud Date: 2004-09-18 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2004-09-30 | |
Well Total Depth: 4030.00 ft | |
Configuration: Vertical | |
Latitude: 41.470000 | |
Longitude: -81.250000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2004-08-09 | Proposed Formations:CLINTON, Issued Date:8/9/2004, Expired Date:8/9/2005 6:00:00 AM, Drilling unit acres:98, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2004-09-18 | RBDMS Rec |
Completed | 2004-09-30 | RBDMS Rec |
Reached Total Depth | 2004-09-30 | RBDMS Rec |
Completion Report Received | 2005-01-04 | RBDMS Rec |
Construction Permit Expires | 2005-08-09 | RBDMS Rec |
Change of Owner | 2016-12-05 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2005-02-22 | 3780 | 3812 | 13 |
3780 | 3812 | 13 | |
3780 | 3812 | 13 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 400 Bbl | 90000 | 598M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2004 | GREAT PLAINS EXPLORATION LLC | 699.00 | 0.00 | 60 |
2005 | GREAT PLAINS EXPLORATION LLC | 706.00 | 0.00 | 365 |
2006 | GREAT PLAINS EXPLORATION LLC | 1154.00 | 0.00 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | 1435.00 | 0.00 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | 292.00 | 0.00 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | 786.00 | 0.00 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | 0.00 | 0.00 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | 462.00 | 0.00 | 55 |
2012 | GREAT PLAINS EXPLORATION LLC | 320.00 | 0.00 | 55 |
2013 | GREAT PLAINS EXPLORATION LLC | 52.00 | 0.00 | 55 |
2014 | GREAT PLAINS EXPLORATION LLC | 15.00 | 0.00 | 55 |
2015 | GREAT PLAINS EXPLORATION LLC | 0.00 | 0.00 | 0 |
2016 | GREAT PLAINS EXPLORATION LLC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2004 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 60 |
2005 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2006 | GREAT PLAINS EXPLORATION LLC | Brine | 80 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | Brine | 320 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | Brine | 80 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 55 |
2012 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 55 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 55 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 55 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 0 |
2016 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-280582911 | 2004-9-20 0:00: | DD | No Violations | |
-563900108 | 2011-1-4 0:00:0 | UP | No Violations | |
-790796476 | 2017-11-28 0:00 | UP | No Violations | |
0280582911 | 2004-09-20 | Drill / Deepen / Reopen | No Violations | surface cementing. |
0294267634 | 2013-08-21 | UrbanProduction Wells | Violations Noted | My inspection found the well to be equipped with a pump jack unit. The pump jack did not have a motor on it. The tank battery consisted of a 210 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The separator does not meet the spacing requirements from the wellhead. The spacing between the separator and the production tank does not meet the requirements. The separator is heat treated but is not being used for that purpose. The proper identification is located on the tank battery. The lease road is in stable condition. I will contact the company about the issues. |
0447307749 | 2016-03-11 | UrbanProduction Wells | No Violations | My inspection found the well to be equipped with a pumpjack. The valves on the wellhead are closed. The tank battery consists of a 210 BBL production tank, a 100 BBL brine tank, and a mechanical separator. Locks need to be installed on the load lines. The dike around the tank battery is in good repair. The proper identification is located on the tank battery. The lease road is in stable condition. The well has not met minimum production since 2012. I have contacted the company about correcting the issues. |
0563900108 | 2011-01-04 | UrbanProduction Wells | Violations Noted | FOLLOW UP TO NOV # 1294758335 Site has been graded, seeded and vegetation is established. Spacing for the well site is not correct and must be corrected. There is only 15 feet between the separator and the wellhead. Spacing between separator and production tanks is not correct, spacing must be 10 feet or more. Separator has a heat treat design it does not appear that the separator is being used as a heat treater. If you are planning on using the separator as a heat treater, spacing must be 50 feet between wellhead and production tanks. Spacing between wellhead and production tanks is not correct, spacing is less than 50 feet. Pictures will be attached to this corrective action. Picture #1 shows distance between separator and production tank as 9.6 feet. Picture # 2 is an overview of the location. Picture #3 Spacing between separator and wellhead is less than 50 feet. Picture #4 shows distance between production tanks as less than 50 feet. |
0790796476 | 2017-11-28 | UrbanProduction Wells | No Violations | At the time of this inspection, the well was equipped with a pumpjack. Valves on the well and flow line were closed. The last reported production that met state requirements was in 2012. The tank battery consisted of one 210 BBL production tank, one 100 BBL brine tank and a heater treater separator. Valves on the separator were closed. The tank battery was diked. Signage at the tank battery location needs to be updated to reflect new company owner information. The lease access was stable. I contacted Rockefeller Oil Company and left a message with the answering service about updating signage and production. |
1236844307 | 2012-02-07 | UrbanPreliminary Restoration | No Violations | No change on location. The spacing between the well and the separator is 15 feet. The spacing between well and production tank is 3210. The spacing between separator and production tank is 9. Spacing needs to be corrected on the location. |
1263297993 | 2004-09-24 | Drill / Deepen / Reopen | No Violations | moving on to location. |
1294758335 | 2011-01-04 | UrbanProduction Wells | Violations Noted | Site has been graded, seeded and vegetation is established. Spacing for the well site is not correct and must be corrected. There is only 15 feet between the separator and the wellhead. Spacing between separator and production tanks is not correct, spacing must be 10 feet or more. Separator has a heat treat design it does not appear that the separator is being used as a heat treater. If you are planning on using the separator as a heat treater, spacing must be 50 feet between wellhead and production tanks. Spacing between wellhead and production tanks is not correct, spacing is less than 50 feet. Pictures will be attached to this corrective action. Picture #1 shows distance between separator and production tank as 9.6 feet. Picture # 2 is an overview of the location. Picture #3 Spacing between separator and wellhead is less than 50 feet. Picture #4 shows distance between production tanks as less than 50 feet. |
1311877237 | 2011-07-13 | Preliminary Restoration | No Violations | Well is shut in. No corrective action have been completed on location. |
1328643059 | 2012-02-07 | UrbanProduction Wells | No Violations | There has been no change on site. Equipment spacing has not been corrected. Spacing between wellhead and separator is 15 feet. Spacing between the separator and production tank 9 10. The spacing between the wellhead and the production tank is 32 10. Spacing needs to be corrected and HB-278 urban equipment needs to be installed - Tanks need hatches that seal, charcoal filter, spark arrestor, low pressure relief valve and lockable valves. The lease road is open and stable and the well is shut in. |
1377091592 | 2013-08-21 | UrbanProduction Wells | No Violations | On site with Inspector Kevin Perry, well is shut in. Spacing has not been corrected on location. Complaince notice remains open. Operator will be contacted by inspector Perry. |
1392907769 | 2014-02-20 | UrbanProduction Wells | Violations Noted | My inspection today is a follow up inspection to compliance notice 294267634. My inspection found no changes since my last inspection. I have advised the company to have someone on location while the well is being produced. |
294267634 | 2013-8-21 0:00: | UP | No Violations | |
447307749 | 2016-3-11 0:00: | UP | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0294267634 | US-OH-123069 | 2014-02-27 | Violation of tank spacing requirements | |
0563900108 | US-OH-126332 | 2014-04-04 | Violation of tank spacing requirements | |
1294758335 | US-OH-108302 | 2014-07-02 | Violation of tank spacing requirements | |
1294758335 | US-OH-108303 | 2014-07-02 | Failure to meet tank battery setbacks from a well | |
1294758335 | US-OH-108304 | 2014-07-02 | Failure to meet oil tank spacing requirements | |
1294758335 | US-OH-108305 | 2014-07-02 | Failure to meet mechanical seperator spacing requirements from wells | |
1392907769 | US-OH-111602 | 2016-07-26 | 9-9-05(A)2 | Violation of tank spacing requirements |
For data sources see[9]