X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21836

Well Details

Well ID: 34-055-21836
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: SUMMIT PETROLEUM INC
Well Pad ID:
Farm/Lease Name: BANDY UNIT
License Status: Producing
License Date: 2005-07-18
Spud Date: 2005-09-06
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-09-18
Well Total Depth: 3800.00 ft
Configuration: Vertical
Latitude: 41.530000
Longitude: -81.370000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-07-18 Proposed Formations:CLINTON, Issued Date:7/18/2005, Expired Date:7/18/2006 6:00:00 AM, Drilling unit acres:25.75, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-09-06
Completed 2005-09-18
Reached Total Depth 2005-09-18
Completion Report Received 2005-12-27
Construction Permit Expires 2006-07-18
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-03-06 3548 3578 20
3548 3578 20
3548 3578 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 84000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 SUMMIT PETROLEUM INC 1849.00 0.00 255
2007 SUMMIT PETROLEUM INC 7507.00 0.00 365
2008 SUMMIT PETROLEUM INC 15189.00 79.00 365
2009 SUMMIT PETROLEUM INC 13938.00 0.00 365
2010 SUMMIT PETROLEUM INC 15612.00 49.00 365
2011 SUMMIT PETROLEUM INC 17250.00 0.00 365
2012 SUMMIT PETROLEUM INC 10378.00 0.00 366
2013 SUMMIT PETROLEUM INC 11064.00 0.00 365
2014 SUMMIT PETROLEUM INC 9534.00 0.00 365
2015 SUMMIT PETROLEUM INC 5841.00 0.00 365
2016 SUMMIT PETROLEUM INC 8337.00 0.00 365
2017 SUMMIT PETROLEUM INC 7645.00 0.00 365
2018 SUMMIT PETROLEUM INC 7643.00 55.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 SUMMIT PETROLEUM INC Brine 245 255
2007 SUMMIT PETROLEUM INC Brine 310 365
2008 SUMMIT PETROLEUM INC Brine 167 365
2009 SUMMIT PETROLEUM INC Brine 174 365
2010 SUMMIT PETROLEUM INC Brine 182 365
2011 SUMMIT PETROLEUM INC Brine 154 365
2012 SUMMIT PETROLEUM INC Brine 83 366
2013 SUMMIT PETROLEUM INC Brine 30 365
2014 SUMMIT PETROLEUM INC Brine 163 365
2015 SUMMIT PETROLEUM INC Brine 85 365
2016 SUMMIT PETROLEUM INC Brine 84 365
2017 SUMMIT PETROLEUM INC Brine 0 365
2018 SUMMIT PETROLEUM INC Brine 78 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1039925246 2013-6-10 0:00: UP No Violations
-1489672973 2007-7-18 0:00: PW No Violations
-1633478049 2016-11-29 0:00 UP No Violations
-1641200629 2006-3-28 0:00: PW No Violations
-1789532891 2006-2-2 0:00:0 DD No Violations
-1891814775 2006-1-23 0:00: DD No Violations
-1937483498 2005-9-7 0:00:0 DD No Violations
-859811760 2006-2-2 0:00:0 DD No Violations
0405412208 2018-07-03 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly. The gate valve on the tubing was open and the 2 inch flow line valve was open. The well was fenced and locked. Reported production was for this well was up-to-date. The tank battery consisted of one 100 BBL production tank, one 100 BBL brine tank and two mechanical separators. The chart on the sales line showed production and the valves on the separators were open. The tank battery was diked and fenced with a locked man door. The lease access was stable. No violations observed.
0859811760 2006-02-02 Drill / Deepen / Reopen Violations Noted FOLLOW UP TO NOV # -1789532891 possible brine dumping on property. NOV hand delivered , Met landowner and Mr. Kinney on site possible brine got into drain tile which is approximately 250-300 to southwest of well and fluid is coming to surface grassy area is dead , pits where solidified advised possible brine dumping on property. NOV hand delivered , Met landowner and Mr. Kinney on site possible brine got into drain tile which is approxiametly 250-300 to southwest of well and fluid is coming to surface grassy area is dead , pits where solidified advis
1039925246 2013-06-10 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open. The tank battery and well are in good repair and are surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 100 BBL brine tank, and two mechanical separators. The proper identification is located on the tank battery. The lease road is in stable condition.
1138114933 2005-10-25 Drill / Deepen / Reopen No Violations on site with Jay Cheslock to check site for possible contamination of yard through trees and approx 350to south west

Landowner said that the grass is dead which is the draiage ditch (east to west) in this area two trees looked stressed one pine is the other possible ash. This well surface casing was set (09/07/2005).No violation pit in good shape no fluid loss in ether drilling or pits. The company had taken steps to remove soil along the drainage area and seeded area Company plans to check area in spring for vegatation cover will redo if needed and also replace trees . No evidence to show that brine was dumped in area.

1187009650 2006-02-21 Production Wells No Violations on site with Dave Hodge to run Em over site could not determine source. Drain tile is south of well site , but no chloride in tile water at time of inspection.
1193844601 2007-10-31 Preliminary Restoration No Violations Site has been graded and seeded. Vegetation is established. Tank battery and well head are fenced, and gates are locked. Dike around battery is in good repair. Lease road is stable and constructed out of durable material. Well head and tank battery spacing good.
1272037033 2010-04-23 Production Wells No Violations Well head and tank battery fence is in good repair. Dike around the battery is in good repair. Lease road is stable. Identification sign is posted. Man doors are locked. Walked area 500 feet west of site. There is a complaint in the area of Stockbridge Drive of a petroleum product on the surface of the water. Material in the ditch appears to be refined oil or fuel. Cl- in the water in the ditch was 83ppm. No brine scalding or crude oil noted west of the well and tank battery. No leaks noted at the well or the tank battery.
1489672973 2007-07-18 Production Wells No Violations Tank battery is fenced and locked, two 100BBL tanks mechanical separator, spacing is good tank battery to well. Well head is fenced and locked no leaks. Vegetation is established around site. On site to check the status of open NOV regarding brine spill, on site with Jay Cheslock DMRM supervisor. Brine spill as been cleaned up and no damage to vegetation noted.
1521253684 2005-09-07 Drill / Deepen / Reopen No Violations Surface 375-8.75
1609011560 2005-08-11 Drill / Deepen / Reopen No Violations site check
1633478049 2016-11-29 UrbanProduction Wells No Violations I conducted an inspection on this well. The well is equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced but not locked. The last reported production was submitted in 2014 for this well. The tank battery consisted of one 100 BBL production tank, one 100 BBL brine tank and two mechanical separators. The chart on the sales line showed production and the valves on the separators were open. The tank valves were plugged. The tank battery was diked and fenced with a locked man door. The lease access was stable.
1641200629 2006-03-28 Production Wells No Violations company had remove toppsoil and replaced. Grass has been established.

Case Closed

1789532891 2006-02-02 Drill / Deepen / Reopen Violations Noted possible brine dumping on property.NOV hand delivered . Met landowner and Mr. Kinney on site possible brine got into drain tile which is apporx 250-300 to southwest of well .The fluid is coming to surface, grassy area is dead , pits where solidified , possible brine dumping on property.
1891814775 2006-01-23 Drill / Deepen / Reopen No Violations no violation pits ok
1937483498 2005-09-07 Drill / Deepen / Reopen No Violations Drilling at 350 surface tonight
405412208 2018-7-3 0:00:0 UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0859811760 US-OH-129801 2006-05-11 Drilling operation causing pollution and contamination
1789532891 US-OH-117838 2006-05-11 Drilling operation causing pollution and contamination

For data sources see[9]

References