34-055-21845

Well Details

Well ID: 34-055-21845
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Russell Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: MASSERIA UNIT
License Status: Producing
License Date: 2005-07-29
Spud Date: 2005-08-30
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2005-09-10
Well Total Depth: 3746.00 ft
Configuration: Vertical
Latitude: 41.470000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-07-29 Proposed Formations:CLINTON, Issued Date:7/29/2005, Expired Date:7/29/2006 6:00:00 AM, Drilling unit acres:21.29, Proposed Well Type:OG, Proposed Well Class:EW
Original Spud 2005-08-30 RBDMS Rec
Completed 2005-09-10 RBDMS Rec
Reached Total Depth 2005-09-10 RBDMS Rec
Completion Report Received 2006-05-09 RBDMS Rec
Construction Permit Expires 2006-07-29 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-07-28 3626 3686 68
3626 3686 68
3626 3686 68

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 74000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION 1032.00 238.00 365
2008 ALLIANCE PETROLEUM CORPORATION 6113.00 762.00 365
2009 ALLIANCE PETROLEUM CORPORATION 3332.00 517.00 365
2010 ALLIANCE PETROLEUM CORPORATION 2372.00 475.00 365
2011 ALLIANCE PETROLEUM CORPORATION 1738.00 441.00 365
2012 ALLIANCE PETROLEUM CORPORATION 1811.00 386.00 366
2013 ALLIANCE PETROLEUM CORPORATION 1538.00 258.00 365
2014 ALLIANCE PETROLEUM CORPORATION 654.00 400.00 365
2015 ALLIANCE PETROLEUM CORPORATION 696.00 355.00 365
2016 ALLIANCE PETROLEUM CORPORATION 1201.00 398.00 365
2017 ALLIANCE PETROLEUM CORPORATION 1317.00 288.00 365
2018 ALLIANCE PETROLEUM CORPORATION 1758.00 341.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 ALLIANCE PETROLEUM CORPORATION Brine 72 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 51 365
2015 ALLIANCE PETROLEUM CORPORATION Brine 54 365
2016 ALLIANCE PETROLEUM CORPORATION Brine 71 365
2017 ALLIANCE PETROLEUM CORPORATION Brine 35 365
2018 ALLIANCE PETROLEUM CORPORATION Brine 30 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1120904884 2017-2-28 0:00: UP No Violations
-1375705143 2005-12-1 0:00: DD No Violations
-174533666 2017-4-4 0:00:0 UP No Violations
-343067607 2006-10-4 0:00: PL No Violations
-397142893 2005-9-12 0:00: CT No Violations
-834211471 2005-8-31 0:00: DD No Violations
-922279148 2005-9-22 0:00: DD No Violations
0174533666 2017-04-04 UrbanProduction Wells No Violations I was onsite to conduct a reinspection of this well site regarding the replacement of a brine tank. The well was equipped with a plunger lift assembly and the valves on the wellhead were open. There was a domestic line off of the 4.5 inch casing with a meter, drip bottle and two regulators. The well was fenced. The tank battery consisted of one 100 BBL production tank, one 25 BBL poly brine tank, a mechanical separator and sales line. The 25 BBL poly brine tank has been repaired. Valves on the separator were open and the chart showed production. The tank valve was equipped with a flat plug and locked. The tank battery was diked and fenced with a locked man door. Proper, legible signage was located at the well and tank battery. Lease access was stable. No violations observed.
0343067607 2006-10-04 Preliminary Restoration No Violations Site has been graded, mulched and seeded. Pit linear sections were still on site, parts of the silt fence were on site. Dave Hill was contacted, once pit linear and silt fence sections are removed, preliminary restoration will be passed.
0397142893 2005-09-12 Completion Testing No Violations
0834211471 2005-08-31 Drill / Deepen / Reopen No Violations checking site
0922279148 2005-09-22 Drill / Deepen / Reopen No Violations
1034489365 2005-08-30 Drill / Deepen / Reopen No Violations Rig moving on
1120904884 2017-02-28 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. There was a domestic line off of the 4.5 inch casing with a meter, drip bottle and two regulators. The well was fenced. Last reported production for this well was in 2014. The tank battery consisted of one 100 BBL production tank, one 25 BBL poly brine tank, a mechanical separator and sales line. The 25 BBL poly brine tank was crushed and needed to be removed. Valves on the separator were open and the chart dated 2/27/17 showed production. The tank valve was equipped with a flat plug and locked. The tank battery was diked and fenced with a locked man door. Proper, legible signage was located at the well and tank battery. Lease access was stable. I contacted Matt Postlathwaite of Alliance Petroleum about removing the crushed brine tank and adding a lock at the well man door.
1160660886 2006-10-12 Preliminary Restoration No Violations Pit linear pieces still on site. Silt fence and safety fence pieces still on site. Restoration cannot be passed until area is cleaned up of debris.
1184174391 2007-07-10 Preliminary Restoration No Violations On site to meet with Ted from TK Gas. Operator has received complaints from the land owner that the well was drilled on, that reclamation was not sufficient. Site has been graded level. A rock lined drainage channel has been constructed on the west side of the site. Tank battery is fenced. Well head is fenced. Locked gate has been installed. Vegetation is established and has went to seed. I suggested to Ted that the company brush hog the site. Lease road is stable. Pine trees have been planted around the well head and tank battery. One pine tree has died and will need to be replaced. Pit liner and safety fence has been cleaned up around the site.
1373905687 2013-07-15 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is closed. There is a house line plumbed into the 4.5 casing. The well and tank battery are in good repair and are surrounded by a locked chain link fence and pine trees. The tank battery consists of a 100 BBL production tank, a 25 BBL poly brine tank, and a mechanical separator. The proper identification is located on the tank battery and the wellhead. The lease road is in stable condition.
1375705143 2005-12-01 Drill / Deepen / Reopen No Violations pits closed
1446135802 2015-10-29 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
1897632424 2005-09-07 Drill / Deepen / Reopen No Violations drilling 3220 TD is to be 3800
2086907856 2005-09-28 Drill / Deepen / Reopen No Violations Checked pit no violation