34-055-21865

Well Details

Well ID: 34-055-21865
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chardon Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: SPORAR
License Status: Producing
License Date: 2005-09-21
Spud Date: 2005-12-31
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-01-06
Well Total Depth: 3977.00 ft
Configuration: Vertical
Latitude: 41.580000
Longitude: -81.260000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-09-21 Proposed Formations:CLINTON, Issued Date:9/21/2005, Expired Date:9/21/2006 6:00:00 AM, Drilling unit acres:52.81, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-12-31 RBDMS Rec
Completed 2006-01-06 RBDMS Rec
Reached Total Depth 2006-01-06 RBDMS Rec
Completion Report Received 2006-03-21 RBDMS Rec
Change of Owner 2006-04-06 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 7909, JOHN D OIL & GAS COMPANY
Construction Permit Expires 2006-09-21 RBDMS Rec
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-06-14 3852 3889 14
3852 3889 14
3852 3889 14

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 553 Bbl 120000 800M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY 6589.00 0.00 306
2007 JOHN D OIL & GAS COMPANY 3210.00 74.00 365
2008 JOHN D OIL & GAS COMPANY 3854.00 26.00 365
2009 JOHN D OIL & GAS COMPANY 2698.00 0.00 365
2010 JOHN D OIL & GAS COMPANY 2293.00 0.00 365
2011 JOHN D OIL & GAS COMPANY 2352.00 17.00 365
2012 JOHN D OIL & GAS COMPANY 1752.00 0.00 366
2013 JOHN D OIL & GAS COMPANY 931.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 803.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 554.00 0.00 365
2016 DAVID OIL COMPANY LLC 56.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY Brine 790 306
2007 JOHN D OIL & GAS COMPANY Brine 280 365
2008 JOHN D OIL & GAS COMPANY Brine 240 365
2009 JOHN D OIL & GAS COMPANY Brine 240 365
2010 JOHN D OIL & GAS COMPANY Brine 280 365
2011 JOHN D OIL & GAS COMPANY Brine 80 365
2012 JOHN D OIL & GAS COMPANY Brine 80 366
2013 JOHN D OIL & GAS COMPANY Brine 80 365
2014 JOHN D OIL & GAS COMPANY Brine 140 365
2015 JOHN D OIL & GAS COMPANY Brine 0 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1489457783 2007-8-13 0:00: PW No Violations
-1961115230 2006-1-13 0:00: DD No Violations
-1980398235 2006-2-17 0:00: DD No Violations
-2042489268 2008-7-15 0:00: PW No Violations
-2056793546 2007-10-17 0:00 PW No Violations
-609479225 2016-3-21 0:00: PW No Violations
0146668413 2013-07-19 Production Wells No Violations My inspection found the well to be equipped with a pump jack. The well and tank battery are in good repair. The tank battery consists of a 210 BBL production tank and a 100 BBL brine tank. A heat treated separator is outside of the tank battery with the proper spacing. The proper identification is located on the tank battery. The lease road is in stable condition.
0273900783 2006-02-06 Production Wells Violations Noted FOLLOW UP TO NOV # 1142875243 Inspected site due to landowner stated that a feeder creek or drainage ditch that feeds into his pond was just all clay

sediment. Hes worried about the fish that are in the pond ( Coy Crap).

Case #06-001 Inspected site due to landowner stated that a feeder creek or drainage ditch that feeds into his pond was just all clay sediment. Hes worried about the fish that are in the pond ( Coy Crap). Advised company to put sediment controls in ditch to stop sai

0394087368 2006-01-11 Drill / Deepen / Reopen No Violations company placed straw bails to control off site sedimentation .
0609479225 2016-03-21 Production Wells No Violations My inspection found the well to be equipped with a pumpjack. The well and tank battery are in good repair. The tank battery consists of a 210 BBL production tank and a 100 BBL brine tank. The load line valves on the tanks have plugs installed in them but are not locked. A heated separator is outside of the tank battery with the proper spacing. The proper identification is located on the tank battery. The lease road is in stable condition.
1142875243 2006-02-06 Production Wells Violations Noted Inspected site due to landowner stated that a feeder creek or drainage ditch that feeds into his pond was just all clay

sediment.Hes worried about the fish that are in the pond ( Coy Crap).

Case #06-001 Inspected site due to landowner stated that a feeder creek or drainage ditch that feeds into his pond was just all clay sediment.Hes worried about the fish that are in the pond ( Coy Crap). Advised company to put sediment controls in ditch to stop sedi

1143483406 2006-01-05 Drill / Deepen / Reopen Violations Noted Inspected site found crew from conpany on site cleaning up the mud on rt 6.

Case closed

1188908590 2007-09-04 Production Wells No Violations Tank battery has two drain pipes installed east side of battery and the south. Called company and issued an NOV for the pipes. Neither pipe have caps on them to prevent the escape of brine and oil if a leak occurs. Area around the well head needs repair seeding to prevent erosion. Pit area needs soil treated and seeded to establish vegetation. There is sedimentation behind the well head. That follows a drainage cut to the east. Sedimentation is deposited in the woods away from the site. Called Tim Riley at the time of inspection and informed him of the issues. Will re-check site on Thursday of this week.
1236877905 2009-03-12 Preliminary Restoration No Violations Repair seeding has been completed. Site is stable, pump jack well has been installed.
1262706045 2006-03-21 Drill / Deepen / Reopen No Violations On site checking violation, feeder stream running clear Case Closed. Company on site Grading area around well.
1312176715 2011-04-05 Production Wells No Violations Dike needs built up. ID sings need placed on both wells. Drain cap needs replaced on drain pipe in the dike.
146668413 2013-7-19 0:00: PW No Violations
1489457783 2007-08-13 Production Wells Violations Noted Area around well head needs, lime, fertilized, seeded and mulched. Sedimentation is evident, drainage flows to the south and south east. The drainage channel had sand and clay fines in it. There is an area in the woods 15X8 that the fines are deposited. Fines all so continue into the woods to the south east. Tank battery dike has two, two inch plastic drain pipes installed. Drain pipes do not have caps. Tank battery dike is not capable of containing spills. Area around well head needs, limed, fertilized, seeded and mulched. Plastic drain pipes installed in the tank battery dike need to be capped at both ends.
1878457954 2006-08-10 Drill / Deepen / Reopen No Violations checking location
1961115230 2006-01-13 Drill / Deepen / Reopen No Violations company setting tank battery checking on sedimentation to east of lease road company working on controling
1980398235 2006-02-17 Drill / Deepen / Reopen No Violations checking location
2042489268 2008-07-15 Production Wells No Violations Landowner to east has complainted about nise from pump jack motor and no fence around well
2056793546 2007-10-17 Production Wells No Violations Area around the well has been repair seeded and mulched vegetation is beginning to become established. Drain pipes in the tank battery have been capped.
273900783 2006-2-6 0:00:0 PW No Violations
394087368 2006-1-11 0:00: DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0273900783 US-OH-122830 2006-03-20 Well operation causing pollution and contamination
1142875243 US-OH-103626 2006-03-20 Well operation causing pollution and contamination
1143483406 US-OH-103652 2006-03-27 Permit violation
1489457783 US-OH-113884 2007-08-13 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)
1489457783 US-OH-113885 2007-08-13 Dike or pit not able to prevent escape of brine or other wastes