X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21866

Well Details

Well ID: 34-055-21866
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chardon Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: POWERS
License Status: Producing
License Date: 2005-09-30
Spud Date: 2006-01-07
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-01-12
Well Total Depth: 4056.00 ft
Configuration: Vertical
Latitude: 41.580000
Longitude: -81.240000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-09-30 Proposed Formations:CLINTON, Issued Date:9/30/2005, Expired Date:9/30/2006 6:00:00 AM, Drilling unit acres:29.18, Proposed Well Type:OG, Proposed Well Class:
Original Spud 2006-01-07 RBDMS Rec
Completed 2006-01-12 RBDMS Rec
Reached Total Depth 2006-01-12 RBDMS Rec
Completion Report Received 2006-03-21 RBDMS Rec
Change of Owner 2006-04-06 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 7909, JOHN D OIL & GAS COMPANY
Construction Permit Expires 2006-09-30 RBDMS Rec
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-06-14 3815 3842 14
3815 3842 14
3815 3842 14

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 556 Bbl 120000 813M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY 20834.00 0.00 326
2007 JOHN D OIL & GAS COMPANY 23892.00 44.00 365
2008 JOHN D OIL & GAS COMPANY 17491.00 29.00 365
2009 JOHN D OIL & GAS COMPANY 14843.00 0.00 365
2010 JOHN D OIL & GAS COMPANY 11985.00 0.00 365
2011 JOHN D OIL & GAS COMPANY 9255.00 0.00 365
2012 JOHN D OIL & GAS COMPANY 5210.00 0.00 366
2013 JOHN D OIL & GAS COMPANY 4195.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 4597.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 4651.00 0.00 365
2016 DAVID OIL COMPANY LLC 852.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY Brine 160 326
2007 JOHN D OIL & GAS COMPANY Brine 480 365
2008 JOHN D OIL & GAS COMPANY Brine 320 365
2009 JOHN D OIL & GAS COMPANY Brine 160 365
2010 JOHN D OIL & GAS COMPANY Brine 160 365
2011 JOHN D OIL & GAS COMPANY Brine 320 365
2012 JOHN D OIL & GAS COMPANY Brine 0 366
2013 JOHN D OIL & GAS COMPANY Brine 0 365
2014 JOHN D OIL & GAS COMPANY Brine 110 365
2015 JOHN D OIL & GAS COMPANY Brine 162 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1334313163 2017-3-13 0:00: UP No Violations
-1395908440 2007-8-13 0:00: PL No Violations
-1519204923 2006-1-13 0:00: DD No Violations
-452410023 2013-7-19 0:00: PW No Violations
-954637498 2012-5-10 0:00: PW No Violations
0452410023 2013-07-19 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is closed. The well and tank battery are in good repair. The tank battery consists of a 210 BBL production tank and a 100 BBL brine tank. A heat treated separator is outside of the tank battery with the proper spacing. The proper identification is located on the tank battery. The lease road is in stable condition.
0954637498 2012-05-10 Production Wells No Violations My inspection today found a plunger lift system well in good repair. The tank battery has one 210 barrel production tank, one 100 barrel brine tank in it. The dike is starting to weather and the operator will be notified to monitor and repair as needed. The dike drain needs a shut off valve or cap installed on the outlet. The separator is a heat treat unit. Equipment spacing is correct at the location.
1334313163 2017-03-13 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. The last reported production for this well shows the records to be up to date. The tank battery consisted of one 210 BBL production tank, one 100 BBL brine tank and a heater treater separator. The separator was located outside of the dike and had open valves, equipped with a chart that showed production. Proper spacing between the production tanks and separator were observed. Tank valves were equipped with equipped with flat plugs. The 100 BBL brine tank was starting to rust through and holes had formed near the top of the tank. The tank battery was diked and the signage needed to be updated to reflect the new owner information. The lease access was stable. I contacted John Magnuson from David Oil Company about removing and replacing the 100 BBL tank and updating the signage.
1395908440 2007-08-13 Preliminary Restoration No Violations Well head is installed. One 210 and one 100 BBL tank one site, heat treat separator on site, spacing is good. Vegetation is established. Lease road is stable and constructed out of durable material.
1458734882 2016-03-22 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is closed. The well and the tank battery are in good repair. The tank battery consists of a 210 BBL production tank and a 100 BBL brine tank. The dike drain was open at the time of inspection and needs to be closed. The heated separator is outside of the tank battery with the proper spacing. The load line valves have plugs installed in them but are not locked. The proper identification sign is installed on the tank battery. The lease road is in stable condition. I have contacted the company about keeping the dike drian closed.
1519204923 2006-01-13 Drill / Deepen / Reopen No Violations Drilling No violation.
1524621620 2012-05-10 Production Wells No Violations On 5/10/2012, I performed a production well inspection status check with DNR Inspectors Tom Hill and Mike Dinsmore. My inspection found the well head was a plunger lift unit (rabbit), that was in good condition. The tank battery contained one 210 barrel oil storage tank with the proper identification posted, one 100 barrel brine tank, and a separator. There was a 2 drain running through the dike wall, please refer to DNR Tom Hills inspection report for the violation status.

For data sources see[9]

References