If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-055-21884 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.52,"lon":-81.33,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Chester Township | |
Operator Name: CUTTER EXPLORATION INC | |
Well Pad ID: | |
Farm/Lease Name: ROMAH | |
License Status: Producing | |
License Date: 2006-04-18 | |
Spud Date: 2006-10-25 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2006-11-03 | |
Well Total Depth: 3944.00 ft | |
Configuration: Vertical | |
Latitude: 41.520000 | |
Longitude: -81.330000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-04-18 | Proposed Formations:CLINTON, Issued Date:4/18/2006, Expired Date:4/18/2007 6:00:00 AM, Drilling unit acres:34.2, Proposed Well Type:OG, Proposed Well Class: |
Reached Total Depth | 2006-11-03 | RBDMS Rec |
Construction Permit Expires | 2007-04-18 | RBDMS Rec |
Completion Report Received | 2008-04-02 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-08-12 | 3751 | 3797 | 18 |
3751 | 3797 | 18 | |
3751 | 3797 | 18 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 57581 Gal | 25000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | CUTTER EXPLORATION INC | 8469.00 | 103.00 | 365 |
2009 | CUTTER EXPLORATION INC | 6014.00 | 101.00 | 365 |
2010 | CUTTER EXPLORATION INC | 5244.00 | 0.00 | 365 |
2011 | CUTTER EXPLORATION INC | 2329.00 | 47.00 | 0 |
2012 | CUTTER EXPLORATION INC | 4925.00 | 53.00 | 366 |
2013 | CUTTER EXPLORATION INC | 5611.00 | 0.00 | 365 |
2014 | CUTTER EXPLORATION INC | 1623.00 | 0.00 | 365 |
2015 | CUTTER EXPLORATION INC | 819.00 | 0.00 | 365 |
2016 | CUTTER EXPLORATION INC | 1768.00 | 0.00 | 365 |
2017 | CUTTER EXPLORATION INC | 0.00 | 1132.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | CUTTER EXPLORATION INC | Brine | 130 | 365 |
2009 | CUTTER EXPLORATION INC | Brine | 30 | 365 |
2010 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2011 | CUTTER EXPLORATION INC | Brine | 0 | |
2012 | CUTTER EXPLORATION INC | Brine | 0 | 366 |
2013 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2014 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2015 | CUTTER EXPLORATION INC | Brine | 13 | 365 |
2016 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2017 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1251806529 | 2006-12-29 0:00 | PL | No Violations | |
-2093676815 | 2009-8-5 0:00:0 | PW | No Violations | |
-28742840 | 2016-6-24 0:00: | UP | No Violations | |
-782188395 | 2015-6-2 0:00:0 | UP | No Violations | |
-889232849 | 2007-7-18 0:00: | PL | No Violations | |
0028742840 | 2016-06-24 | UrbanProduction Wells | No Violations | I conducted a status check inspection on this well. The well is equipped with a plunger lift unit and the valves on the wellhead were open. There was a domestic line with two meters off of the 4.5 inch casing on the well. The well is fenced, but needs the man door lock replaced. The well location needs the vegetation removed and maintained. Signage needs added at the well. The tank battery consists of two, 100 BBL production tanks, two mechanical separators, and one, 50 BBL steel brine tank. The tank battery is shared with well 21889. The load lines in the tank battery need plugs and the vegetation also needs to be maintained and removed. The signage at the tank battery was legible and correct. The access to the wellsite was stable. I called Mark Turpak from Cutter Exploration, and discussed the vegetation maintenance, new lock installation and adding signage at the well. |
0072508930 | 2006-11-06 | Drill / Deepen / Reopen | No Violations | Rig is offsite. Pits are open. Safety fence needs to be installed the east side of the pits. Operator will be pumping pits the next two days. |
0116310957 | 2014-12-18 | UrbanProduction Wells | No Violations | My inspection found no changes since my last inspection. No violations found. |
0174655425 | 2013-06-07 | UrbanProduction Wells | No Violations | My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open. The tank battery and well are in good repair and surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL brine tank, and two mechanical separators. The proper identification is located on the tank battery and the wellhead. The lease road is in stable condition. The lease road and tank battery are being shared by permit number 2-1889. |
0400893029 | 2016-10-19 | UrbanProduction Wells | No Violations | I conducted a follow-up inspection on this well from the previous inspection conducted on 6/24/2016. The well is equipped with a plunger lift unit and the valves on the wellhead were open. There was a domestic line with two meters off of the 4.5 inch casing on the well. The well is fenced, but needed a man door lock. The lock has been replaced. The well location needed the vegetation removed and maintained. At the time of this inspection, the vegetation has been maintained. Signage needed added at the well and now has been installed at the well location. The tank battery consists of two, 100 BBL production tanks, two mechanical separators, and one, 50 BBL steel brine tank. The tank battery is shared with well 2-1889. The load lines in the tank battery needed plugs and the vegetation also needed to be maintained and removed. It was observed that new plugs were installed on the tank valves and vegetation maintained at the time of this inspection. The signage at the tank battery was legible and correct. The access to the wellsite was stable. |
0417709845 | 2013-10-02 | UrbanProduction Wells | No Violations | I am on location due to a water well complaint #4484 at 8921 Sherman Rd. My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open. The tank battery and well are in good repair and surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL brine tank, and two mechanical separators. The proper identification is located on the tank battery and the wellhead. The lease road is in stable condition. The lease road and tank battery are being shared by permit number 2-1889. |
0666758532 | 2007-06-18 | Preliminary Restoration | No Violations | Reclamation has been completed on site. Vegetation is beginning to become established. Well head is fenced, tank battery is fenced. No signs up at this time. Two 110 BBl tank and two mechanical separators on site. Dike is up around the tank battery. |
0782188395 | 2015-06-02 | UrbanProduction Wells | No Violations | My inspection found the brine contaminated stone had been removed from inside the tank battery and replaced with new stone. The load lines have bull plugs in them but are in need of locks on the valves. The sealed lids on the production tanks are missing the nuts to secure them down. No other changes to the location since my last inspection. I contacted Mark Turpak about the getting locks on the load line and nuts to secure the tank lids. |
0889232849 | 2007-07-18 | Preliminary Restoration | No Violations | Site has been seeded and graded. Piles of overburden are still in the woods around the site. These will need to be pulled out and blended in. Dike for the tank battery north east side of the dike needs finished. There is no corner to the dike, clay will need to be added to finish the last three feet of the dike. Well and tank battery is locked, ID signs need put up, signs are posted at the entrance of the site. |
116310957 | 2014-12-18 0:00 | UP | No Violations | |
1194371716 | 2007-11-06 | Preliminary Restoration | No Violations | Site has been graded and seeded. Vegetation is established. Spacing is good between production tank and well head. Brine takes are within 50 of the well head. |
1251806529 | 2006-12-29 | Preliminary Restoration | No Violations | Pits have been filled in. Service crew on site installing tank battery. Lease road in poor condition. Soil is very soft. |
1496450622 | 2011-08-17 | Production Wells | No Violations | Two 100Bbl tanks one 50Bbl tank, two mechincal separators are in the battery. Hatch on the right hand tank needs the seal replaced. Identification sign needs put up on the fence. Identification sign is on the ground. |
174655425 | 2013-6-7 0:00:0 | UP | No Violations | |
2093676815 | 2009-08-05 | Production Wells | No Violations | Well head needs ID sign. Well head, cage and lock to man door are in good repair. |
400893029 | 2016-10-19 0:00 | UP | No Violations | |
417709845 | 2013-10-2 0:00: | UP | No Violations | |
666758532 | 2007-6-18 0:00: | PL | No Violations | |
72508930 | 2006-11-6 0:00: | DD | No Violations |
For data sources see[9]