X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21889

Well Details

Well ID: 34-055-21889
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: BARILLE
License Status: Producing
License Date: 2006-06-05
Spud Date: 2006-11-05
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2006-11-13
Well Total Depth: 3944.00 ft
Configuration: Vertical
Latitude: 41.520000
Longitude: -81.320000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-06-05 Proposed Formations:CLINTON, Issued Date:6/5/2006, Expired Date:6/5/2007 6:00:00 AM, Drilling unit acres:22.458, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2006-11-13 RBDMS Rec
Construction Permit Expires 2007-06-05 RBDMS Rec
Completion Report Received 2008-04-02 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-08-12 3731 3793 25
3731 3793 25
3731 3793 25

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 54971 Gal 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 CUTTER EXPLORATION INC 15959.00 81.00 365
2009 CUTTER EXPLORATION INC 14159.00 105.00 365
2010 CUTTER EXPLORATION INC 17287.00 55.00 365
2011 CUTTER EXPLORATION INC 8601.00 42.00 0
2012 CUTTER EXPLORATION INC 6993.00 51.00 366
2013 CUTTER EXPLORATION INC 8347.00 0.00 365
2014 CUTTER EXPLORATION INC 8850.00 26.00 365
2015 CUTTER EXPLORATION INC 5012.00 56.00 365
2016 CUTTER EXPLORATION INC 6314.00 0.00 365
2017 CUTTER EXPLORATION INC 0.00 2654.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 CUTTER EXPLORATION INC Brine 75 365
2009 CUTTER EXPLORATION INC Brine 150 365
2010 CUTTER EXPLORATION INC Brine 230 365
2011 CUTTER EXPLORATION INC Brine 140
2012 CUTTER EXPLORATION INC Brine 70 366
2013 CUTTER EXPLORATION INC Brine 75 365
2014 CUTTER EXPLORATION INC Brine 70 365
2015 CUTTER EXPLORATION INC Brine 42 365
2016 CUTTER EXPLORATION INC Brine 0 365
2017 CUTTER EXPLORATION INC Brine 80 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1230077322 2006-12-29 0:00 PL No Violations
-126928303 2011-8-17 0:00: PW No Violations
-231070782 2016-10-19 0:00 UP No Violations
-40950702 2007-11-6 0:00: PL No Violations
-431000398 2013-10-2 0:00: UP No Violations
-625547088 2009-8-5 0:00:0 PW No Violations
-798997082 2007-7-18 0:00: PL No Violations
0040950702 2007-11-06 Preliminary Restoration No Violations Site has been seeded and graded. A Landscape wall has been left to block the neighbors view of the power lines. Called Mike Cutter and requested a land owner waiver for the landscape wall. Wall is being used a an ATV jump at this time. I made Mike aware of this problem. Steps will need to be taken to prevent further ATV use. Well head needs signed. Well is produced into a mutual tank battery. Called Mike and asked that the well be signed. Lease road is stable.
0126928303 2011-08-17 Production Wells No Violations Pin leak were the domestic gas supply come off of the well. Battery is in good repair. Well head is in good repair.
0231070782 2016-10-19 UrbanProduction Wells No Violations I conducted a follow-up inspection on this well from the previous inspection conducted on 6/24/2016. The well is equipped with a plunger lift unit and the valves are open. The well is fenced but the man door needed a new lock. A new lock was installed on the man door at the well location. The tank battery consists of two, 100 BBL production tanks, two mechanical separators, and one, 50 BBL steel brine tank. The tank battery is shared with well 2-1884. The load lines in the tank battery needed plugs and the vegetation also needed to be maintained and removed. At the time of this inspection, tank valve plugs were installed on the production tanks and the vegetation has been maintained. The signage at the tank battery was legible and correct. The access to the wellsite was stable.
0321360740 2015-06-02 UrbanProduction Wells No Violations My inspection found the brine contaminated stone had been removed from inside the tank battery and replaced with new stone. The load lines have bull plugs in them but are in need of locks on the valves. The sealed lids on the production tanks are missing the nuts to secure them down. No other changes to the location since my last inspection. I contacted Mark Turpak about the getting locks on the load line and nuts to secure the tank lids.
0323652521 2016-06-24 UrbanProduction Wells No Violations I conducted a status check inspection on this well. The well is equipped with a plunger lift unit and the valves are open. The well is fenced but the man door needs a new lock. The tank battery consists of two, 100 BBL production tanks, two mechanical separators, and one, 50 BBL steel brine tank. The tank battery is shared with well 21884. The load lines in the tank battery need plugs and the vegetation also needs to be maintained and removed. The signage at the tank battery was legible and correct. The access to the wellsite was stable. I called Mark Turpak from Cutter Exploration, and discussed the vegetation maintenance, new lock installation and adding signage at the well.
0431000398 2013-10-02 UrbanProduction Wells No Violations I am on location due to a water well complaint #4484 at 8921 Sherman Rd. My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open. The tank battery and well are in good repair and surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL brine tank, and two mechanical separators. The proper identification is located on the tank battery and the wellhead. The lease road is in stable condition. The lease road and tank battery are being shared by permit number 2-1884.
0481149678 2013-06-07 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open. The tank battery and well are in good repair and surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL brine tank, and two mechanical separators. The proper identification is located on the tank battery and the wellhead. The lease road is in stable condition. The lease road and tank battery are being shared by permit number 2-1884.
0625547088 2009-08-05 Production Wells No Violations Lock on well head and tank battery. Well head and tank battery are in good repair. Well head needs ID sign on it. Contacted operator request ID sign.
0798997082 2007-07-18 Preliminary Restoration No Violations Site has been graded and seeded. A landowner waiver will need to be submitted for a topsoil/ overburden stockpile. The stockpile is being used as a landscape visual barrier. Stockpile will need to be seeded and vegetation established. Once waiver is in restoration can be passed.
1162928320 2006-11-06 Drill / Deepen / Reopen No Violations On site for surface cement. Erosion controls need to be installed ASAP. Lease road was under construction at the time of inspection. Cement to surface.
1182179439 2007-06-18 Plug / Plug Back No Violations Site has been seeded and graded. Well head has been fenced. Site has a stockpile of topsoil on it that will need to be removed before restoration can be approved. Lease road has been restored. Tank battery will need signed.
1221745272 2008-09-18 Preliminary Restoration No Violations Site is seeded and graded. Reclamation is complete. Well is caged. ID sign at the entrance to the site and the tank battery. ID sign needs placed at the well head. Called Daniel Passerini requested ID sign at the well head.
1230077322 2006-12-29 Preliminary Restoration No Violations Well head has been installed. Pits have been closed, there was standing water on the pits. Safety fence is still up. Will contact operator to clean up pits. Service crew on site installing flow lines to tank battery. Lease road in poor condition, soil is very soft.
1418914268 2014-12-18 UrbanProduction Wells No Violations My inspection found the oil contaminated area inside the tank battery has been cleaned up. No other changes to the location since my last inspection.
1631491141 2006-11-08 Drill / Deepen / Reopen No Violations Drilling active, hole is 5 degrees off operator is working on correcting problem. Pit water level OK. Diversion ditches and silt fence have been installed.
321360740 2015-6-2 0:00:0 UP No Violations
323652521 2016-6-24 0:00: UP No Violations
481149678 2013-6-7 0:00:0 UP No Violations

For data sources see[9]

References