34-055-21895

Well Details

Well ID: 34-055-21895
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Auburn Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: LADUE TRAILS
License Status: Producing
License Date: 2006-08-04
Spud Date: 2006-08-17
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2006-08-23
Well Total Depth: 4183.00 ft
Configuration: Vertical
Latitude: 41.370000
Longitude: -81.210000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-08-04 Proposed Formations:CLINTON/MEDINA, Issued Date:8/4/2006, Expired Date:8/4/2007 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-08-17 RBDMS Rec
Completed 2006-08-23 RBDMS Rec
Reached Total Depth 2006-08-23 RBDMS Rec
Completion Report Received 2006-12-05 RBDMS Rec
Construction Permit Expires 2007-08-04 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-02-01 3997 4078 100
3997 4078 100
3997 4078 100

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 82570 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION 14741.00 530.00 365
2008 ALLIANCE PETROLEUM CORPORATION 32115.00 593.00 365
2009 ALLIANCE PETROLEUM CORPORATION 30587.00 320.00 365
2010 ALLIANCE PETROLEUM CORPORATION 23110.00 227.00 365
2011 ALLIANCE PETROLEUM CORPORATION 9753.00 139.00 365
2012 ALLIANCE PETROLEUM CORPORATION 14050.00 116.00 366
2013 ALLIANCE PETROLEUM CORPORATION 9801.00 54.00 365
2014 ALLIANCE PETROLEUM CORPORATION 12177.00 193.00 365
2015 ALLIANCE PETROLEUM CORPORATION 11985.00 140.00 365
2016 ALLIANCE PETROLEUM CORPORATION 11651.00 111.00 365
2017 ALLIANCE PETROLEUM CORPORATION 13286.00 48.00 365
2018 ALLIANCE PETROLEUM CORPORATION 14222.00 141.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 ALLIANCE PETROLEUM CORPORATION Brine 34 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 95 365
2015 ALLIANCE PETROLEUM CORPORATION Brine 153 365
2016 ALLIANCE PETROLEUM CORPORATION Brine 32 365
2017 ALLIANCE PETROLEUM CORPORATION Brine 64 365
2018 ALLIANCE PETROLEUM CORPORATION Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1171526204 2006-8-28 0:00: PW No Violations
-1927556114 2016-12-13 0:00 UP No Violations
-861935532 2015-5-6 0:00:0 UP No Violations
0105600133 2014-08-19 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open. The well is surrounded by a wooden fence. The tank battery consists of two 100 BBL production tanks, a 25 BBL poly brine tank, and two mechanical separators. The tank battery is surrounded by a locked chain link fence. The production tanks are vented through charcoal filters and up into spark arrestors. The proper identification is located on the well and the tank battery. The lease road is in stable condition. The tank battery is being shared by permit number 2-1888.
0147851354 2012-03-02 UrbanProduction Wells No Violations This well is equipped with a plunger lift system. The well is fenced, landscaped, an identification sign is posted and the man door is locked. The back pressure regulator is leaking and I contacted the well tender and left a message regarding this issue. The tank battery is equipped with two 110 barrel production tanks, one 1000 gallon poly brine tank and two mechincal separators. The man door is locked. The operator has constructed a boardwalk inside of the tank battery, which has ground water seeps that cause an accumulation of water inside the dike. The location is in good repair and the lease road is stable. Landscaping is established and the operator has installed visual barriers around the tank battery.
0743404303 2018-02-22 UrbanProduction Wells No Violations During this inspection the well is equipped with a plunger lift assembly and the annulus and flow line valves were open. The well was fenced and locked. Production for this well was up-to-date. The tank battery consisted of two 100 BBL production tanks, one 35 BBL poly brine tank and two mechanical separators. The valves on the separators were open and both charts showed production. The tank battery is shared with well 2-1888. Spark arrestors and the correct lids and hatches were installed on the production tanks. A charcoal filter was plumbed into the vent stack on the production tank. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the well and tank battery and the lease access was stable. No violations observed.
0861935532 2015-05-06 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
105600133 2014-8-19 0:00: UP No Violations
1156778415 2006-08-24 Production Wells Violations Noted Rat hole not cemented to the top. Trash and debris in rat hole. Clean out rat hole and top off with cement.
1171526204 2006-08-28 Production Wells Violations Noted Violation has been corrected.
1176193126 2007-08-28 Preliminary Restoration No Violations Site has been graded and seed. Vegetation is established. Landscaping has been added around the well head and tank battery. Well head and tank battery has been fenced, locks were on gates.
147851354 2012-3-2 0:00:0 UP No Violations
1927556114 2016-12-13 UrbanProduction Wells No Violations I conducted an inspection on this well. The well is equipped with a plunger lift assembly and the valves on the wellhead were open. There was a domestic line off of the 4.5 inch casing with a meter, two regulators and a drip bottle. The well was fenced and locked. The last reported production for this well was submitted in 2014. The tank battery consisted of two 100 BBL production tanks, one 35 BBL poly brine tank and two mechanical separators. The valves on the separators were open and both charts showed production. The tank battery is shared with well 2-1888. The tank valves were plugged and locked. Spark arrestors and the correct lids and hatches were installed on the production tanks. A charcoal filter was plumbed into the vent stack on the production tank. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the well and tank battery and the lease access was stable.
329815704 2019-10-29 0:00 UP No Violations 0.40
743404303 2018-2-22 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1156778415 US-OH-104126 2006-08-28 General Safety
1171526204 US-OH-104537 2006-08-28 General Safety

For data sources see[9]

References