If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-055-21906 | ![]() Sorry, we have no imagery here. Sorry, we have no imagery here. Sorry, we have no imagery here. ![]() |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Chester Township | |
Operator Name: CUTTER EXPLORATION INC | |
Well Pad ID: | |
Farm/Lease Name: ALEXANDER E | |
License Status: Producing | |
License Date: 2006-08-31 | |
Spud Date: 2006-11-25 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2006-12-02 | |
Well Total Depth: 3944.00 ft | |
Configuration: Vertical | |
Latitude: 41.520000 | |
Longitude: -81.350000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-08-31 | Proposed Formations:CLINTON, Issued Date:8/31/2006, Expired Date:8/31/2007 6:00:00 AM, Drilling unit acres:92.83, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2006-12-02 | |
Construction Permit Expires | 2007-08-31 | |
Completion Report Received | 2008-04-02 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-09-26 | 3714 | 3776 | 27 |
3714 | 3776 | 27 | |
3714 | 3776 | 27 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 61218 Gal | 25000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | CUTTER EXPLORATION INC | 453.00 | 8.00 | 365 |
2009 | CUTTER EXPLORATION INC | 2487.00 | 48.00 | 365 |
2010 | CUTTER EXPLORATION INC | 1646.00 | 0.00 | 365 |
2011 | CUTTER EXPLORATION INC | 856.00 | 0.00 | 0 |
2012 | CUTTER EXPLORATION INC | 680.00 | 0.00 | 366 |
2013 | CUTTER EXPLORATION INC | 1023.00 | 0.00 | 365 |
2014 | CUTTER EXPLORATION INC | 359.00 | 0.00 | 365 |
2015 | CUTTER EXPLORATION INC | 227.00 | 0.00 | 365 |
2016 | CUTTER EXPLORATION INC | 112.00 | 0.00 | 365 |
2017 | CUTTER EXPLORATION INC | 0.00 | 88.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | CUTTER EXPLORATION INC | Brine | 15 | 365 |
2009 | CUTTER EXPLORATION INC | Brine | 279 | 365 |
2010 | CUTTER EXPLORATION INC | Brine | 20 | 365 |
2011 | CUTTER EXPLORATION INC | Brine | 0 | |
2012 | CUTTER EXPLORATION INC | Brine | 0 | 366 |
2013 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2014 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2015 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2016 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2017 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1704349233 | 2007-5-23 0:00: | PL | No Violations | |
-874073282 | 2017-3-6 0:00:0 | UP | No Violations | |
0450171064 | 2007-07-18 | Preliminary Restoration | No Violations | Site has been seeded and vegetation is established. Lease road is stable and constructed out of durable material. Well head and tank battery is fenced and locked. Sign is up on tank battery. Dike around tank is in good repair. |
0606204274 | 2006-11-30 | Drill / Deepen / Reopen | No Violations | Drill Depth 3090. Operator is drilling on fluid mixed with air. Pit safety fence is up, silt fence is in place. Pit water level is good over two feet of free board. |
0874073282 | 2017-03-06 | UrbanProduction Wells | No Violations | During this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. There was a 5 gallon charcoal filter that had been plumbed off of the annulus valve. The last reported production for this well was in 2015. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. Valves on the separator were open and the chart showed production. The production tank vent stack was plumbed into a 55 gallon charcoal filter and topped with a spark arrestor. Tank valves were equipped with flat plugs. The tank battery was diked and fenced with a locked man door. Proper, legible signage was located at the tank battery. The lease access was stable. No violations observed. |
1077002438 | 2013-06-11 | UrbanProduction Wells | No Violations | My inspection found the well to be equipped with a plunger lift unit. The annulus is open and plumbed into a 5 gallon charcoal filter. The well and tank battery are in good repair and are surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 50 BBL brine tank, and a mechanical separator. The production tanks vent is plumbed into a 55 gallon charcoal filter and then into a spark arrestor. The proper identification is located on the tank battery. The lease road is in stable condition. |
1210090956 | 2008-05-06 | Production Wells | No Violations | Tank battery is in good repair. Lease road is stable. Spacing is good. Gates are locked. Permit ID sign is up. Dike around tank battery is in good repair. |
1704349233 | 2007-05-23 | Preliminary Restoration | No Violations | Operator on site working on reclamation. Area has been ruff graded. Tank battery has been fenced as well as the well head. Gates area locked. Permit sign is still up. One 110BBl and One 50 BBL tank on site. Mechanical separator. Disturbed area for the gas line has been seeded. |
450171064 | 2007-7-18 0:00: | PL | No Violations | |
606204274 | 2006-11-30 0:00 | DD | No Violations |
For data sources see[9]