X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21908

Well Details

Well ID: 34-055-21908
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Russell Township
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: EOUV
License Status: Producing
License Date: 2006-09-01
Spud Date: 2007-01-16
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-01-23
Well Total Depth: 3900.00 ft
Configuration: Vertical
Latitude: 41.470000
Longitude: -81.330000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-09-01 Proposed Formations:CLINTON, Issued Date:9/1/2006, Expired Date:9/1/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-01-23
Reached Total Depth 2007-01-23
Completion Report Received 2007-06-29
Construction Permit Expires 2007-09-01
Change of Owner 2015-05-12 Operator changed from 1639, BASS ENERGY CO INC to 935, BOCOR HOLDINGS, LLC/BOCOR PROD
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-10-19 3734 3761 52
3734 3761 52
3734 3761 52

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 52100 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
0 0 0
2007 BASS ENERGY CO INC 2527.00 92.00 365
2008 BASS ENERGY CO INC 3621.00 91.00 365
2009 BASS ENERGY CO INC 691.00 75.00 365
2010 BASS ENERGY CO INC 1867.00 69.00 365
2011 BASS ENERGY CO INC 1065.00 0.00 0
2012 BASS ENERGY CO INC 1179.00 66.00 366
2013 BASS ENERGY CO INC 1015.00 81.00 365
2014 BASS ENERGY CO INC 1127.00 68.00 365
2015 BOCOR HOLDINGS, LLC 360.00 33.00 148
2016 BOCOR HOLDINGS, LLC 1009.00 33.00 365
2017 BOCOR HOLDINGS, LLC 713.00 106.00 365
2018 BOCOR HOLDINGS, LLC 549.00 49.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 BASS ENERGY CO INC Brine 14 365
2008 BASS ENERGY CO INC Brine 2 365
2009 BASS ENERGY CO INC Brine 115 365
2010 BASS ENERGY CO INC Brine 110 365
2011 BASS ENERGY CO INC Brine 65
2012 BASS ENERGY CO INC Brine 56 366
2013 BASS ENERGY CO INC Brine 0 365
2014 BASS ENERGY CO INC Brine 60 365
2015 BOCOR HOLDINGS, LLC Brine 50 148
2016 BOCOR HOLDINGS, LLC Brine 55 365
2017 BOCOR HOLDINGS, LLC Brine 0 365
2018 BOCOR HOLDINGS, LLC Brine 41 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-268352781 2015-10-29 0:00 UP No Violations
-638424993 2013-7-15 0:00: UP No Violations
0268352781 2015-10-29 UrbanProduction Wells No Violations My inspection found the well has been recently purchased from Bass Energy by Bocor Holdings. The company has placed an updated identification sign on location. No other changes since my last inspection. No violations found.
0638424993 2013-07-15 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open. The well and tank battery are in good repair and are surrounded by a locked chain link fence. The tank battery consists of a 100 BBL production tank, a 50 BBL brine tank, and a mechanical separator. The production tank is vented through a 5 gallon charcoal filter and into a spark arrestor. The proper identification is located on the tank battery and the wellhead. The lease road is in stable condition.
0662158370 2017-10-10 UrbanProduction Wells No Violations During this inspection, the well was equipped with a plunger lift assembly and the valves on the annulus and flow line was open. Production records for this well were current. The well was fenced. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. Valves on the separator were open. There was a 5 gallon charcoal filter plumbed off of the vent stack on the 100 BBL tank and topped with a spark arrestor. The tank battery was diked and fenced with a locked man door. The signage was located at the tank battery, and the lease access was stable. No violations were observed.
1168631951 2007-01-12 Drill / Deepen / Reopen No Violations Site is under construction. Lease road is under construction. Changes made, operator may cement conductor, there is a water well less than 100 feet from well site. Safety fence will only be needed to the south of site and around the pits.
1168980208 2007-01-16 Drill / Deepen / Reopen No Violations Rig moving on site. Well will be spudded this after noon.
1169059192 2006-11-17 Drill / Deepen / Reopen No Violations On site for CND cement. Hl#1 42 17 42 of 11.75 set. 75 sacks of Class A 3% 3bbl return. Pits are in clay, no ground water coming in. Silt fence is up. Operator will put up safety fence once pits are complete. Lease road is stable.
1169741322 2007-01-25 Drill / Deepen / Reopen No Violations Rig is offsite, Silt fence is up around site. Safety fence is up around pits west and south side. North and east side of the pits topsoil is begin used as a safety barrier. Site has 12 + inches of snow on it at the time of inspection. Site is frozen and stable.
1256146937 2009-10-21 Production Wells No Violations Well site is in good repair. Annulus is open and bubbling at the surface. Called Ralph from Bass Energy suggest either plumbing the annulus into tank battery or plumbing it above ground with a pop off. Ralph said he would get some one out to plumb the annulus above grade and put a pop off on it.
1449219654 2007-07-31 Preliminary Restoration No Violations Operator has fenced site with 8 plastic coated chain link. Lease road has not been restored, drainage ditch at the road needs repaired and positive drainage obtained. Area around the well head has been graded and seeded. There is a stockpile of gas line and a road drag that has to be removed from the site.
1759065469 2007-07-19 Preliminary Restoration No Violations Affected area where the drilling rig and pits were located, has been graded. Lease road has not been restored. Lease road slopes from the field north of Pekin road to Pekin road. Approximately a 5:1 slope. The rock that the lease road was constructed out of has sank into the clay soil. A top coat of gravel will need to be added to the lease road. Operator has affected area along Pekin road 20 to the west and 25 to the east of the lease road for the installation of the gas line. Slope is 1:1 from the road ditch north to the site along Pekin road. The slope is not seeded, the slope will need graded, seeded and mulched. The culvert at the end of the lease road (Pekin road exit), east end of culvert has been crushed and is plugged. There is standing water on the east side of the culvert. Drainage flows to the east. Culvert will need repaired or replaced. Positive drainage will need to be restored in the roadway ditch. Tank batter and well head is not fenced at this time. Well needs to be fenced before it is put into production. Called Ralph from Bass Energy at the time of inspection, made him aware of the needed reclamation work.
2066392882 2007-07-26 Production Wells Violations Noted Well is in production, spoke with Chuck from Dominion well was put on line 07/13/2007. Well head and tank battery have not been fenced. Pressure on the gauge on the well was 300lb. HB-278 tank battery and well head need fenced before a well is put into production. Well head and tank battery need fenced and locked before well is put back into production.
662158370 2017-10-10 0:00 UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
2066392882 US-OH-121065 2007-07-26 General Safety

For data sources see[9]

References