X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21909

Well Details

Well ID: 34-055-21909
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: NUSRALA
License Status: Producing
License Date: 2006-09-05
Spud Date: 2006-09-22
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-09-29
Well Total Depth: 3652.00 ft
Configuration: Vertical
Latitude: 41.550000
Longitude: -81.380000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-09-05 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:9/5/2006, Expired Date:9/5/2007 6:00:00 AM, Drilling unit acres:58.78, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-09-29
Reached Total Depth 2006-09-29
Completion Report Received 2007-06-27
Construction Permit Expires 2007-09-05
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-10-18 3460 3495 38
3460 3495 38
3460 3495 38

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 48287 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 BASS ENERGY CO INC 10042.00 0.00 365
2008 BASS ENERGY CO INC 55155.00 62.00 365
2009 BASS ENERGY CO INC 64276.00 70.00 365
2010 BASS ENERGY CO INC 73185.00 0.00 365
2011 BASS ENERGY CO INC 56916.00 64.00 0
2012 BASS ENERGY CO INC 30634.00 0.00 366
2013 BASS ENERGY CO INC 27390.00 0.00 365
2014 BASS ENERGY CO INC 22404.00 0.00 365
2015 BASS ENERGY CO INC 15002.00 0.00 365
2016 BASS ENERGY CO INC 11505.00 0.00 365
2017 BASS ENERGY CO INC 10859.00 0.00 365
2018 BASS ENERGY CO INC 8927.00 28.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 BASS ENERGY CO INC Brine 84 365
2008 BASS ENERGY CO INC Brine 65 365
2009 BASS ENERGY CO INC Brine 192 365
2010 BASS ENERGY CO INC Brine 105 365
2011 BASS ENERGY CO INC Brine 72
2012 BASS ENERGY CO INC Brine 23 366
2013 BASS ENERGY CO INC Brine 68 365
2014 BASS ENERGY CO INC Brine 75 365
2015 BASS ENERGY CO INC Brine 70 365
2016 BASS ENERGY CO INC Brine 0 365
2017 BASS ENERGY CO INC Brine 37 365
2018 BASS ENERGY CO INC Brine 35 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1680555852 2013-6-18 0:00: UP No Violations
-1979634616 2006-9-26 0:00: DD No Violations
-53180984 2006-10-2 0:00: DD No Violations
-981124789 2007-7-31 0:00: PL No Violations
0053180984 2006-10-02 Drill / Deepen / Reopen No Violations Drill rig off site. Safety fence up. Pit water level okay.
0543644710 2017-03-07 UrbanProduction Wells No Violations During this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced and locked. Reported production for this well was up to date. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. Valves on the separator were open and the chart dated 3/1/17 showed production. The production tank valve was plumbed into a 55 gallon charcoal filter and topped with a spark arrestor. The tank valves were equipped with flat plugs and locks. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the well and tank battery. The lease access was stable and secured with a locked gate. No violations were observed.
0981124789 2007-07-31 Preliminary Restoration No Violations Site has been seeded and graded. Tank battery is fenced and locked, well head is fenced. Vegetation is established. Lease road has been restored. Silt fence behind the tank battery can be removed, vegetation is established. Tank battery is signed.
1158944481 2006-09-22 Drill / Deepen / Reopen No Violations Status check of site. Operator has constructed less road. Silt fence has been installed east of lease road. Stone was being installed at the time of inspection. Rig was moving on. Operator had permit posted on site. Per operator neighbor removed permit. Operator will be re-posting permit. Operator was reminded to put up silt fence north of drill site. Rig was Cap Star Rig #3.
1159215299 2006-09-24 Drill / Deepen / Reopen No Violations On site for Surface Cement. 85/8 pipe was new. Good return on cement to surface.
1159369046 2006-09-27 Drill / Deepen / Reopen Violations Noted Rig is approximately 600 from total depth. The safety fence has not been installed around the pits. Pits fence needs to be installed by 5:00 PM on 09/27/2006.
1161019536 2006-10-16 Drill / Deepen / Reopen No Violations Pits have been closed on site. Silt fence is still up. Safety fence has been removed from site.
1175207267 2007-03-29 Preliminary Restoration No Violations On site in response to a complaint filled on the site regarding reclamation. Lease road is flooded. Pits have been filled in. Tank battery has been installed. One 110 BBl tank installed. One 50 BBL tank installed. Mechanical separator. Site has not been reclaimed. Drainage controls are still in place. Well was spudded 09/22/2007, reclamation is due by
1315858499 2006-09-28 Drill / Deepen / Reopen No Violations Safety fence was up and in good condition. NOV is passed.
1531938075 2018-07-18 UrbanProduction Wells No Violations During this inspection, the well was equipped with a plunger lift assembly and the gate valve on the tubing was open. The 2 inch flow line valve was open. The well was fenced and had a locked man door. Reported production for this well was up to date. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. Valves on the separator were open. The production tank valve was plumbed into a 55 gallon charcoal filter and topped with a spark arrestor. The tank valves were equipped with flat plugs and locks. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the well and tank battery. The lease access was stable and secured with a locked gate. No violations were observed.
1680555852 2013-06-18 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The well and tank battery are in good repair. The tank battery is surrounded by a chain link fence and pine trees and the wellhead is surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 50 BBL brine tank, and a mechanical separator. The vent off of the production tank is plumbed through a 55 gallon charcoal filter and then up into a spark arrestor. The proper identification is located on the tank battery and the wellhead. The lease road is in stable condition.
1979634616 2006-09-26 Drill / Deepen / Reopen No Violations Drill depth at the time of inspection 1899. Safety fence needs put up around drill pits. 3 of free board around east drill pits. West drill pit has extra pit to the south, for overflow.
543644710 2017-3-7 0:00:0 UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1159369046 US-OH-104227 2006-09-27 Permit violation

For data sources see[9]