X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21924

Well Details

Well ID: 34-055-21924
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: INDUSTRY STANDARD SUPPLIES INC
Well Pad ID:
Farm/Lease Name: PAROS UNIT
License Status: Producing
License Date: 2007-01-26
Spud Date: 2007-01-31
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-02-07
Well Total Depth: 3787.00 ft
Configuration: Vertical
Latitude: 41.540000
Longitude: -81.360000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-01-26 Proposed Formations:CLINTON, Issued Date:1/26/2007, Expired Date:1/26/2008 6:00:00 AM, Drilling unit acres:20.6291, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-02-07
Reached Total Depth 2007-02-07
Completion Report Received 2007-06-13
Construction Permit Expires 2008-01-26
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-10-03 3610 3682 47
3610 3682 47
3610 3682 47

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 52402 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 INDUSTRY STANDARD SUPPLIES INC 4432.00 301.00 365
2009 INDUSTRY STANDARD SUPPLIES INC 3360.00 187.00 365
2010 INDUSTRY STANDARD SUPPLIES INC 3507.00 195.00 365
2011 INDUSTRY STANDARD SUPPLIES INC 3422.00 175.00 365
2012 INDUSTRY STANDARD SUPPLIES INC 3226.00 175.00 366
2013 INDUSTRY STANDARD SUPPLIES INC 3003.00 126.00 365
2014 INDUSTRY STANDARD SUPPLIES INC 3102.00 123.00 365
2015 INDUSTRY STANDARD SUPPLIES INC 3260.00 139.00 365
2016 INDUSTRY STANDARD SUPPLIES INC 2766.00 109.00 365
2017 INDUSTRY STANDARD SUPPLIES INC 2434.00 144.00 365
2018 INDUSTRY STANDARD SUPPLIES INC 2189.00 77.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2009 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2010 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2011 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2012 INDUSTRY STANDARD SUPPLIES INC Brine 0 366
2013 INDUSTRY STANDARD SUPPLIES INC Brine 14 365
2014 INDUSTRY STANDARD SUPPLIES INC Brine 106 365
2015 INDUSTRY STANDARD SUPPLIES INC Brine 43 365
2016 INDUSTRY STANDARD SUPPLIES INC Brine 29 365
2017 INDUSTRY STANDARD SUPPLIES INC Brine 52 365
2018 INDUSTRY STANDARD SUPPLIES INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1202880994 2013-8-21 0:00: UP No Violations
-1433423400 2007-10-31 0:00 PL No Violations
-1631581253 2007-1-29 0:00: DD No Violations
-1706860909 2007-11-1 0:00: PL No Violations
-1824390244 2017-3-6 0:00:0 UP No Violations
-1969630068 2008-5-6 0:00:0 PL No Violations
-466721695 2007-2-7 0:00:0 DD No Violations
0024507015 2007-05-15 Preliminary Restoration No Violations Operator has installed fences around well head and tank battery. One dozer on site, operator is currently reclaiming site. Operator has used wooden privacy fencing. Lease road is stable, drainage ditch needs seeded, operator constructed a drainage ditch along the lease road to the road ditch. Vegetation will need to be established to prevent erosion. Called office requested a key for gates.
0177575327 2007-02-05 Drill / Deepen / Reopen No Violations Pit fluid level good and pit linear was in good condition. Safety fence was not up, will be in place ASAP. Operator is using topsoil as a safety berm around the pits, and to control drainage. Drill depth was 2853. Site was frozen.
0466721695 2007-02-07 Drill / Deepen / Reopen No Violations checking location
0547217851 2010-10-27 Production Wells No Violations Drainage ditch continues to erode and increase in size. Ditch needs to be stabilized and rocked. Identification sign is faded out. Identification sign needs corrected. Load lines are outside of the dike and there is oil staining on the ground. Load lines need to be moved back into the dike. North most load line is directly above a drainage ditch. Lease road gate is locked. Lease road is stable. Key needs to be sent to inspector.
0797457147 2011-09-09 Production Wells No Violations Operator has been requested in the past to line the drainage channel that discharges into a ditch adjacent to Wilson Mills Road with stone. They have recently placed cobble sized stone in this drainage channel but it still needs to be stabilized due to minimal native vegetation on the sides of the channel. Also, the type of material placed in the channel will have a minimal impact on preventing the erosion and cutting of the channel. Limestone or other angular stone should have been used for stabilization instead of the cobble. The operator also installed a spill preventer on the load lines.
0920319811 2013-06-19 Preliminary Restoration No Violations My inspection found the well to be equipped with a plunger lift unit. The well has a house line plumbed into the 4.5 casing. The wooden fence around the wellhead is missing a side. The tank battery consists of a 100 BBL production tank, a 50 BBL brine tank, and a mechanical separator. The production tank is vented through a 55 gallon charcoal filter and up into a spark arrestor. The tank battery is surrounded by a wooden fence. The drainage ditch has established vegetation in it. The identification sign is faded and needs updated. No production was reported for 2012. A key for access to the location and equipment needs sent to the inspector. I will contact the company with the issues.
1173198199 2007-03-06 Drill / Deepen / Reopen Violations Noted Tank battery parts on site. Tank battery is not installed. Pits are open, spud date was 01/31/2007. Pit liners have slump into pit. Safety fence is in poor condition around pits. Safety fence has fallen down. Lease road is open and stable. Pits need solidified and closed by 03/16/2007. Weather the past 30 days has been heavy snow and rain. Contacted company 03/06/2007 11:42 am of NOV and that pits need filled in by 03/16/2007 and that safety fence and pit linear need repaired. Pit liner needs to be put back into place and repaired. Safety fence needs repaired, (put back up.) Pits need to be solidified within 30 days of the completion of drilling.
1202880994 2013-08-21 UrbanProduction Wells No Violations My inspection today found there has been no changes since my last inspection. No violations.
1222877519 2008-10-01 Preliminary Restoration No Violations NOV not passed at this time. Area around well head has been graded, vegetation is not established area is barren. Operator has load line 2 feet out of tank battery, there is oil and brine on the ground. Drainage ditch that runs in front of the tank battery to the road ditch is eroding. Bank of the ditch is eroding. Ditch needs rock lined. No lock on the well head man door. I have Pre-site this week with Industry Standard, will discus site at that time with them.
1223407347 2008-10-07 Preliminary Restoration No Violations Site needs repaired seeding. Drainage ditch needs rock lined. Ive spoken to Tim Levengood regarding the repairs. He stated they will be getting ditch rock lined.
1433423400 2007-10-31 Preliminary Restoration No Violations Site has been ruff graded. Site was seeded, seed did not take. Brush needs removed from site. Debris pile is on site south west of well head. Drainage channel on the east side of lease road is not rock lined as per the permit. Lease road gate has not been installed. Called Tim, site need some more grading work before seeding and cleaned up. Will be back out in a couple of weeks to check progress.
1631581253 2007-01-29 Drill / Deepen / Reopen No Violations surface for Tom Hill
1706860909 2007-11-01 Preliminary Restoration No Violations
1722901527 2008-05-06 Preliminary Restoration Violations Noted Lease road gate is closed. Site has been ruff graded. Vegetation is not established. Drainage ditch to the east of lease road needs graded and seeded. Tank battery has been fenced with a wood fence. Fence is locked. There is crude oil in the drainage ditch leading away from the tank battery. It appears that the tank battery has overflowed. Dike needs improved around the tank battery. Site needs final grading and seeding. Vegetation needs to be established. Oil from the drainage ditch needs removed, tank battery needs clean. Oil in the ditch is a few spots less than a quart of oil. Called Tim left him a message regarding site needs
1771959960 2009-10-19 Preliminary Restoration No Violations Vegetation is established at the wellhead. Wellhead man door lock is missing. Lease road is stable. Drainage ditch to the east of the lease road needs stabilized. Called Tim Levengood regarding lock on man door, ditch repairs and ID signs needing repaired. ID signs have faded out, contact information is up, cant read permit information.
177575327 2007-2-5 0:00:0 DD No Violations
1824390244 2017-03-06 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. There was a domestic line plumbed off of the 4.5 inch casing with one regulator and two meters. There was an audible gas leak coming from the tubing packing on the well. The well fencing had been damaged and needed to be repaired. The last reported production was submitted in 2015. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. Valves on the separator were open and the chart dated 3/1/17 showed production. The production tank vent stack was plumbed into a 55 gallon charcoal filter and topped with a spark arrestor. Tank valves were equipped with flat plugs and locked. The tank battery was diked but the north side of the dike needed to be rebuilt. The fencing around the tank battery had been damaged by fallen trees and needed to be repaired. Proper signage was located at the tank battery and the lease access was stable. I contacted Tim Levengood from Industry Standard Supplies, 330-343-3711 about the tubing packing leak, repairing both the well and tank battery fences, and rebuilding the dike.
1969630068 2008-05-06 Preliminary Restoration No Violations FOLLOW UP TO NOV # 1722901527 Lease road gate is closed. Site has been ruff graded. Vegetation is not established. Drainage ditch to the east of lease road needs graded and seeded. Tank battery has been fenced with a wood fence. Fence is locked. There is crude oil in the drainage ditch leading away from the tank battery. It appears that the tank battery has overflowed. Dike needs improved around the tank battery.
24507015 2007-5-15 0:00: PL No Violations
547217851 2010-10-27 0:00 PW No Violations
797457147 2011-9-9 0:00:0 PW No Violations
920319811 2013-6-19 0:00: PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1173198199 US-OH-104567 2007-03-07 Dike or pit not able to prevent escape of Brine or other wastes
1173198199 US-OH-104568 2007-03-07 Failure to fill pits within 5 mos. (CHANGE) (REPLACE)
1722901527 US-OH-117090 2014-05-30 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)

For data sources see[9]

References