Well Details

Well ID: 34-055-21937
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Hambden Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: LILLY
License Status: Producing
License Date: 2007-04-30
Spud Date: 2007-11-01
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2007-11-07
Well Total Depth: 3865.00 ft
Configuration: Vertical
Latitude: 41.630000
Longitude: -81.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-04-30 Proposed Formations:CLINTON, Issued Date:4/30/2007, Expired Date:4/29/2008 6:00:00 AM, Drilling unit acres:21, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-11-07
Reached Total Depth 2007-11-07
Completion Report Received 2008-01-02
Construction Permit Expires 2008-04-29
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2016-12-14

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-01-22 3678 3750 23
3678 3750 23
3678 3750 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 400 Bbl 25000 FRAC BAFFLE @ 3738… THIS FRAC ALSO USED 252 MSCF OF N2
H2O 0 400 Bbl 75000 THIS FRAC ALSO USED 632 MSCF OF N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 JOHN D OIL & GAS COMPANY 2523.00 0.00 309
2009 JOHN D OIL & GAS COMPANY 2457.00 26.00 365
2010 JOHN D OIL & GAS COMPANY 2129.00 0.00 365
2011 JOHN D OIL & GAS COMPANY 1860.00 0.00 365
2012 JOHN D OIL & GAS COMPANY 1973.00 0.00 366
2013 JOHN D OIL & GAS COMPANY 2099.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 2092.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 177.00 0.00 365
2016 DAVID OIL COMPANY LLC 0.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 JOHN D OIL & GAS COMPANY Brine 800 309
2009 JOHN D OIL & GAS COMPANY Brine 160 365
2010 JOHN D OIL & GAS COMPANY Brine 315 365
2011 JOHN D OIL & GAS COMPANY Brine 160 365
2012 JOHN D OIL & GAS COMPANY Brine 120 366
2013 JOHN D OIL & GAS COMPANY Brine 102 365
2014 JOHN D OIL & GAS COMPANY Brine 0 365
2015 JOHN D OIL & GAS COMPANY Brine 0 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1145467334 2016-3-22 0:00: PW No Violations
-1211769237 2019-1-3 0:00:0 PW No Violations 0.60
-1782220515 2007-11-1 0:00: DD No Violations
-1804388419 2007-11-2 0:00: DD No Violations
-74756027 2013-7-25 0:00: PW No Violations
0074756027 2013-07-25 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is closed. The well and tank battery are in good repair. The tank battery consists of a 100 BBL production tank. There is no separator on location. The landowner informed me the separator was removed and the well has not produced since last year. Production records are up to date and show production for 2012. The lease road needs repaired. It is not passable with a vehicle to the well. The proper identification is on the tank battery. I spoke with Jim from Great Plains about the repairs and he stated that they were scheduled to be fixed.
0217929047 2018-10-17 Production Wells Violations Noted I conducted an inspection on this well. The well was equipped with a plunger lift assembly and not in production at the time of this inspection. Production records were last submitted in 2016 as zero. 2017 production records have not been submitted at the time of this inspection. The tank battery consisted of one 100 BBL production tank. The tank battery was diked. Signage was present at the tank battery but needed updated current owner information. The lease access was stable. The owner must place ID in compliance with OAC 1501-9:9-05(A)(10) by no later than 10/24/18 or be subject to additional enforcement. Contact Inspector Shannon Mullins at 330-413-5921.
1145467334 2016-03-22 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The valves in the wellhead are in the closed position. The annulus valve is closed. The well and the tank battery are in good repair. The tank battery consists of a 100 BBL production tank. The load line valves have plugs installed in them but are not locked. The heated separator is outside of the tank battery with the proper spacing. The flow line valve on the separator is in the closed position. The proper identification sign is installed on the tank battery. The lease road is in stable condition.
1211769237 2019-01-03 Production Wells Violations Noted I conducted an inspection on this well. At the time of this inspection, the well was equipped with a plunger lift assembly and not in production. The valves on the tubing and flow line were closed. Production records were last submitted in 2016 as zero. According to the state database, production records show no submission for 2017 for this well. The tank battery was comprised of one 100 BBL production tank. No other production equipment was present at the tank battery for this well. The tank battery was diked. Identification has not been installed at the well site location as required on compliance notice 217929047. The lease access was stable. I spoke with landowner Dan Lilly inquiring about this well. Mr. Lilly stated he has not received any royalty checks from the company for at least three years or more.

The well owner shall submit a written plugging schedule to Inspector Shannon Mullins at ODNR Division of Oil and Gas Resources Management, 3575 Forest Lake Drive, Suite 150, Uniontown, OH 44685 within 30 days. The well owner/operator will be notified if the plugging schedule is approved or denied. The Lilly 13B shall be plugged within 180 days.

1236359254 2009-03-06 Preliminary Restoration No Violations Site needs pit liner debris cleaned up. Repair seeding this spring maybe need if vegetation doesnt reestablish its self. Lease road needs dressed up. Called Tim from John D Oil informed him that road needs graded and pit liner debris needs picked up. Follow up restoration inspection will be need to make sure site is repaired.
1491942735 2018-05-30 Production Wells No Violations I conducted an inspection on this well in regards to complaint #5723. The well was equipped with a plunger lift assembly and not in production at the time of this inspection. Production records were last submitted in 2016 as zero. 2017 production records were not available at the time of this inspection. The tank battery consisted of one 100 BBL production tank. The tank battery was diked. Signage was present at the tank battery but needed to be updated to reflect current owner information. The lease access was stable. I contacted the David Oil Company, LLC about updating the signage.
1509375582 2017-10-17 Production Wells No Violations I conducted an inspection on this well in regards to complaint #5723. Landowner Dan Lilly was concerned about the well production status. At the time of this inspection, I met with landowner Dan Lilly on site and the well was equipped with a plunger lift assembly and the annulus and flow line valves were closed. Production records for this well were submitted in 2015 with 177 mcf of gas and in 2016 as zero. The tank battery consisted of one 100 BBL production tank. The tank battery was diked. Signage was present at the tank battery but needed to be updated to reflect current owner information. The lease access was stable. I contacted the David Oil Company, LLC at 440-951-1111 and spoke with a Jenny Corrao. She informed me that the field superintendent would be notified about updating the signage.
1578585485 2020-1-9 0:00:0 PW No Violations 1.20
1782220515 2007-11-01 Drill / Deepen / Reopen No Violations On site for CND cement. Conductor pipe set at 28. Hole was 12.25 pipe was 11.75. Cement returned to surface. Pits are in good repair. Fluid level is good. Tested water from the work pit, 384 NaCl ppm. Lease road is stable and in good repair.
1804388419 2007-11-02 Drill / Deepen / Reopen No Violations On site for surface cement. Berea top 134 bottom 190. Surface set at 246 KB. 8.625 pipe new R-3 20 lb. Hole was 11 inches TD at 270. Operator pumped cement until it returned to surface, 15 BBL return of cement to surface. Plug down at 10:00am. Operator can break off at 4:00pm.
217929047 2018-10-17 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0217929047 US-OH-122162 2018-11-08 9-9-05(A)10 Failure to legibly identify well
1211769237 US-OH-105545 2019-01-18 NONE Well shall be plugged

For data sources see[9]