If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-055-21983 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.37,"lon":-81.35,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Bainbridge Township | |
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR | |
Well Pad ID: | |
Farm/Lease Name: ENGLISH | |
License Status: Producing | |
License Date: 2007-10-02 | |
Spud Date: 2007-10-18 | |
Spud Drilling Contractor: WILDCAT DRILLING | |
Final Drill Date: 2007-10-26 | |
Well Total Depth: 3926.00 ft | |
Configuration: Vertical | |
Latitude: 41.370000 | |
Longitude: -81.350000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-10-02 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:10/2/2007, Expired Date:10/1/2008 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-10-26 | |
Reached Total Depth | 2007-10-26 | |
Completion Report Received | 2007-12-19 | |
Construction Permit Expires | 2008-10-01 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-04-24 | 2628 | 2630 | 9 |
2008-04-24 | 3600 | 3602 | 10 |
3720 | 3740 | 56 | |
3600 | 3602 | 10 | |
2628 | 2630 | 9 | |
2628 | 2630 | 9 | |
2008-01-18 | 3720 | 3740 | 56 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 1207 Bbl | 29000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | OHIO VALLEY ENERGY SYSTEMS COR | 767.00 | 96.00 | 21 |
2012 | OHIO VALLEY ENERGY SYSTEMS COR | 12946.00 | 198.00 | 366 |
2013 | OHIO VALLEY ENERGY SYSTEMS COR | 9782.00 | 88.00 | 365 |
2014 | OHIO VALLEY ENERGY SYSTEMS COR | 6769.00 | 0.00 | 365 |
2015 | OHIO VALLEY ENERGY SYSTEMS COR | 6680.00 | 101.00 | 365 |
2016 | OHIO VALLEY ENERGY SYSTEMS COR | 5933.00 | 100.00 | 365 |
2017 | OHIO VALLEY ENERGY SYSTEMS COR | 4896.00 | 0.00 | 365 |
2018 | OHIO VALLEY ENERGY SYSTEMS COR | 4998.00 | 96.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 646 | 21 |
2012 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 354 | 366 |
2013 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 224 | 365 |
2014 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 432 | 365 |
2015 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 212 | 365 |
2016 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 68 | 365 |
2017 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 145 | 365 |
2018 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 72 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1231922454 | 2007-10-18 0:00 | DD | No Violations | |
-1841875912 | 2012-7-9 0:00:0 | PW | No Violations | |
-190302428 | 2009-4-7 0:00:0 | PL | No Violations | |
-1969816142 | 2008-1-28 0:00: | PL | No Violations | |
-1996013768 | 2011-7-14 0:00: | DD | No Violations | |
-2049506477 | 2008-4-28 0:00: | PL | No Violations | |
-2101879437 | 2011-7-13 0:00: | DD | No Violations | |
-2139852812 | 2008-11-24 0:00 | PW | No Violations | |
-322017743 | 2008-1-31 0:00: | PL | No Violations | |
-325428102 | 2011-7-12 0:00: | DD | No Violations | |
-407939722 | 2009-2-23 0:00: | DD | No Violations | |
-611767054 | 2007-10-24 0:00 | DD | No Violations | |
-619284662 | 2008-2-19 0:00: | DD | No Violations | |
-661544853 | 2007-12-15 0:00 | WR | No Violations | |
-707370636 | 2013-5-22 0:00: | UP | No Violations | |
-729492596 | 2008-7-30 0:00: | PL | No Violations | |
0064989375 | 2012-03-07 | Production Wells | No Violations | Repair on the pressure regulator has been made. Site is in good repair. No violations noted at the time of my inspection. |
0171260674 | 2007-10-18 | Drill / Deepen / Reopen | No Violations | Pits under construction. Pits are in clay no ground water noted. Lease road is stable and constructed out of durable material. Permit sign is posted. |
0190302428 | 2009-04-07 | Preliminary Restoration | No Violations | On site with Sean Logan DMRM director. No change on site since last inspection. Went door to door and meet with landowners affected by the gas charging of the aquifer. |
0322017743 | 2008-01-31 | Preliminary Restoration | No Violations | On site to check annulus pressure on well. Ted Hill from Ohio Valley on site during inspection. Annulus pressure at 9:42am was 52psi. Open annulus to relieve pressure, well annulus pressure down to 0psi at 9:43am. At 9:50am the annulus had a pressure of 30psi. At 10:30am Ted Hill and I decided to remove the pop off valve and allow the wells annulus pressure to bleed down to zero. 7950 Scotland drive has had an increase in LEL readings at the hot and cold water tap. 17820 English drive the well head reading have went from a 0LEL reading to a 22LEL reading. Well will be monitored for LEL change. Pop off valve will remain on permit 1811. Permit 1811 has a psi of 22. It was planned to move the well at 7950 Scotland up into the Berea sandstone. Water well at this time is below the Berea. Raising the well, was to see if the gas coming into the house through the water would increase or decrease. Will wait to raise well until Friday or Monday. Land owner at 7950 has a DMRM gas meter and a meter supplied to them by the company. |
0325428102 | 2011-07-12 | Drill / Deepen / Reopen | No Violations | J Well service is the owner of the service rig. Tom Wood on site. At 8:20am tubing depth 2320, Cement top 2388 to 2408. Plug 2578 and perfs 2628 to 2630. |
0331075441 | 2008-01-29 | Preliminary Restoration | No Violations | 10:00am on site to check annulus pressure. Annulus pressure on the well was 33psi. Ted Hill has installed a 10psi to 50psi pop off valve. At 10:00am we turned the adjustment on the pop off valve 1/2 turn to increase pop off pressure. At 12:35pm annulus had a pressure of 35psi. I turned the valve one full turn to increase pressure. Pressure on annulus at 12:57pm was 39psi. Removed needle gauge from annulus and bleed annulus pressure down to zero. Put needle gauge back on annulus. 12:57 annulus pressure was zero. 12:59pm annulus pressure was 20psi, 1:07pm annulus pressure was 22psi, 1:20pm annulus pressure was 30psi, 1:40pm annulus pressure was 32psi. |
0367869179 | 2007-12-15 | Drill / Deepen / Reopen | No Violations | Phone call from Ken Folson EMA Geauga Cty at 8:30 Am Saturday because gas in water well along English Drive A gas well being drilled by Ohio Valley Energy Mr. Folson said company on site trying to solve problem arrived on site at 9:30 AM talked with Ben Funderburg,on phone compy is working on getting rooms for residence that were evicted and also water replacement for homes that need. At the site I talked with Dale Nethings regrading what company plans to do Found out what company plans to do with well also talked with Tom Woods he said they plan to set packer above cemnt at bottom 4.5 casing the perf and squeeze to surface. They are waiting on president on Ohio Valley to arrive on site.Bob Wostal arrived to assist as I was going out to meet Fire Chief Fire Chief Phane I advised as to what should be done toWater wells to get gas moving out of water and to keep people out at leased for the night or until gas drops to acceptable leval. |
0407939722 | 2009-02-23 | Drill / Deepen / Reopen | No Violations | No change on site. Annulus is open. LEL reading of 4% on the annulus. |
0611767054 | 2007-10-24 | Drill / Deepen / Reopen | No Violations | Drill rig is active. Drill depth is 2574. Silt fence and drainage controls are in place. Permit sign is up. Lease road is stable and constructed out of durable material. Culverts are in place. Pits are in good repair, Operator was damming the channel between the hole and the work pit. Fluid was flowing back into sub base. Pit liners are in good repair. |
0619284662 | 2008-02-19 | Drill / Deepen / Reopen | No Violations | on site helping geologist with sampling letters delivering on kingswood drive |
0626518353 | 2007-10-29 | Drill / Deepen / Reopen | No Violations | On site regarding a complaint of mud on the road, no drainage controls along the lease road, and no gravel at the end of the lease road. No one on site at the time of inspection. Rig has moved off site. Gravel at the end of the drive has been worked into the clay soil. Operator needs to bring another load of rock on site and repair the entrance to the lease road. There was dried mud on the road and gravel. Roadway needs cleaned up. Silt fence needs installed along the lease road to prevent erosion. Called company spoke to Rick, regarding needs. Spoke to Dale, he will make repairs and get the road broom back on site. Spoke to Dale in the morning of 10/30/2007. Employee who is responsible for cleaning the road got a speaking to regarding the quality of work completed. Load of stone is coming, for the lease road. Drainage controls will also be installed. |
0661544853 | 2007-12-15 | Work Over Reconditioning | No Violations | On site at 11:00am met with Bob Worstall at the Bainbridge Police Department, regarding one house explosion, five homes on English Drive and two homes on Kingswood drive and five homes on Scotland drive having gas in the water wells and homes. Per the operator it was found that the annular pressure of the well was 300-350 psi. Operator had been blowing the well and the annular space down since 12/14/2007. At this time the operator doesnt know if their well is causing the gas to be in the water wells, but is being proactive regarding the gas in the water wells. At the time I arrived at the well site, operator was pulling tubing from the well. Operator is planning on setting a bridge plug, perforating the 4.5 inch production pipe and cementing the annular space of the well. Operator set bridge plug at 3657 pressure tested plug at 2000 psi for 3 minutes, plug held. Operator perforated the 4.5 inch production casing at 3600-3602 with nine hollow steel carriers. Operator broke circulation through the perforations with salt water. Hole was gassing and producing a light brown oil. Operator then ran sweep through the perforated casing and annular space. Operator then ran 800 sacks of 50/50 pozmix cement. Operator lost circulation during cement job for approximately 5 minutes. Circulation was regained, no cement returned to surface. Majority of the gas was stopped after cementing was complete. Operator could hold back gas at the discharge with his hand. Operator plumbed the annulus into a frac tank on site. Operator will have an employee on site to monitor the well. |
0707370636 | 2013-05-22 | UrbanProduction Wells | No Violations | My inspection found the well to be equipped with a plunger lift unit. The annulus valve was open. The well and tank battery are in good repair and are surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 50 BBL poly brine tank, and a mechanical separator. The production tank is vented through a 55 gallon charcoal filter. There is spark arrestors on the top of the vent stacks. The proper identification is located on the tank battery and the well. The lease road is in stable condition. |
0729371856 | 2007-12-16 | Work Over Reconditioning | No Violations | Status check on well. Well is gassing into frac tank. Ted Hill on site. Plumbers are coming to start work on venting and supplying homes with water. |
0729492596 | 2008-07-30 | Preliminary Restoration | No Violations | Lease road is stable, gate was locked. Area where pits were located has been seeded. Valves on the annulus have locks on them. The valves are locked in a open position. |
0770476226 | 2010-12-03 | UrbanPreliminary Restoration | No Violations | A tree limb has fallen across the lease road 75 feet before the well. Well was static. Annulus was open. Lease road was stable. Lease road gate was locked. Locks were on all the valves for the annulus. |
1028565438 | 2011-07-22 | Preliminary Restoration | No Violations | Lease road gate is locked. Tubing has been ran into the well. Pit was open, safety fence was up around pit with no entry signs posted. Frac tank was on location. Lease road gate was stable. |
1046911505 | 2008-01-18 | Preliminary Restoration | No Violations | Tested annulus space for LEL readings, with Ohio Valleys SensitGold Gas leak detector. 88% to 98% LEL reading at the 2 pipe coming off of the 8.625 pipe. 8.625 pipe is gassing passively. No pressure noted. |
1112058155 | 2010-04-09 | Production Wells | No Violations | Annulus is open. LEL at the annulus was 19%. Lease road is stable. Vegetation is established. Lease road gate is locked. |
1133944879 | 2010-04-13 | Production Wells | No Violations | Lease road gate is locked. Lease road is stable. Vegetation is established. No change at well site. |
1192818501 | 2007-10-16 | Drill / Deepen / Reopen | No Violations | Site has been cut. Lease road has been installed. Operator was clearing area for the rig. Permit and company sign has been posted. Bobcat with a road broom was on site. |
1194018860 | 2007-11-02 | Drill / Deepen / Reopen | No Violations | Operator is closing pits at the time of inspection. Operator has added two loads of cement fines to the pits. Operator was actively mixing pits. Back pit had been solidified and was starting to firm up. Front pit was being emptied into the 2nd back pit and was being mixed. Cement was reacting very well producing heat and dust. Lease road on site was stable. English drive was in good repair and clean of mud. Drainage controls are in place. Tank battery pad was under construction. |
1198684785 | 2007-12-15 | Drill / Deepen / Reopen | No Violations | At approximately 09:30 am I received a call from Supr. Cheslock requesting my assistance in a natural gas leak and explosion in Bainbridge Township, Geauga County. Insp Lowder was reportedly in route and messages had been left for Insp. Hill. Upon arrival I met with Insp. Lowder, the Bainbridge Fire Chief and Deputy Fire Chief. We discussed canvasing the neighborhood with three man teams including Fire Department and Dominion East Ohio personnel to meter LEL levels in the homes. Several reports indicated that some water wells are located in the basements, which would appear to pose a higher risk. We were also advised that there was a problem at the water well at the Bainbridge Police Department. The Fire Chief stated that he would provide MRM with the inspection results. Insp. Claus was contacted and provided support by researching water well records on the ODNR web site. Insp Hill and I then met with Cal Marks (Transcontinental Oil & Gas) and John Fleming (Range Resources) and inspected their respective wells also located in the general area. By early afternoon the neighborhood canvas results indicated that 12 homes (five on English, five on Scotland and two on Kingwood) had detected levels (above 1% LEL) in either the home or at the water well. These people were advised that Ohio Valley had made hotel reservations for all affected people and that they would be updated as information became available. For the remainder of the day and night, Insp. Hill and I worked with and witnessed the corrective actions that Ohio Valley was undertaking to correct the problem and stem the gas flow. |
1199465920 | 2007-12-17 | Work Over Reconditioning | No Violations | On site for 2nd squeeze job, of the annulus space on well 21983. Appalachian Well Survey was running a temperature log at the time of my arrival. Quick review of Temperature logs by Tom Wood, showed areas of potential sources of gas at 1684, 1580, 1410, 1310 and 1230. Appalachian Well Survey didnt set a 2nd bridge plug. Operator had ran 30 feet of cement on top of the wiper plug during first squeeze job of the well. Appalachian Well Survey perforated with nine hollow steel carriers from 2628 to 2630 . Universal Well Services broke circulation and then squeezed 800 sacks of 50/50 pozmix cement. During the process of perforating the 4.5 inch pipe and gaining circulation, a hand stated, that three more water wells had blown out. I left the site to check the annulus pressure on permit 21946. Tom Wood felt that there had to be another source, contributing to the gas in the area. Annulus space on permit 21946 had a bull plug and a needle gauge on it. Needle gauge was reading zero. Returned to well site, Universal Well Services was pumping cement. 41 barrel return of cement to surface. After the completion of the cement job, Operator will continue to allow well to vent into frac tank. I spoke to Tom Wood, regarding the well and any issues that they had. Tom indicated that during the cementing of the long string, they lost 700 of cement to the Packer Shell. This was indicated on the bond log. During the fracturing of the Clinton, 44,000 barrels of water and 300 sacks of sand into the job there was communication between the 4.5 inch pipe the annulus. |
1200594476 | 2008-01-17 | Preliminary Restoration | No Violations | One site with Ted Hill from Ohio Valley Energy. Ted has installed a 25psi pop of valve and a needle gauge on the wells annulus space. Annulus space is open at this time. Operator will close annulus space once other well owners installs similar units. Will run test on Annulus space pressures of the gas wells in the area, the week of January 28, 2008. Tank battery has been ruffed in. |
1204749786 | 2008-03-05 | Preliminary Restoration | No Violations | On site with Ted Hill from OVE, I requested that Ted take off well fittings covering the annulus space of the well. Ted was able to get all but one retaining ring off of the well. The space Ted opened up was enough to allow a line to be lowered into the annulus space. I lowered a tap measure line into the annulus space, in an attempt to tag the cement from the squeeze job. Ted and I also attached a weight to the end of the tap, to allow it to pass through the water in the annulus. Tape went down approximately 13 feet without tagging cement. Ted will remove the final retaining ring 03/06/2008. He will also bring 1/4 steel rods to attempt to tag cement and obtain a sample of the cement. Gas bubbling vigorously in the annulus space was heard by myself and Ted. |
1204823387 | 2008-03-06 | Preliminary Restoration | No Violations | On site with Ted Hill from OVE. Ran a steel rod into the annulus space to tag the cement from the second squeeze job. Cement was approximately 5 feet below grade. Top 1/2 inch of cement appeared to be soft. When the cement was struck with a steel rod you could feel that the surface was soft. Cement deeper than a 1/2 inch below the surface of the cement, felt solid when struck with a steel rod. Attempted to take a core sample of the cement with steel tube, 1/2 inch of cement in the tube was all that was obtained. Annulus space has approximately 4.5 of water in it. Sample of the water was obtained from the annulus space. Water had 969 ppm Chloride. Gas was still bubbling in the annulus space. Ted reassembled the well head and put retaining ring back on. Ted allow fittings on the annulus space to be lose, to allow gas to escape. 17990 English took static water reading. Static water level was 89 feet. Static water level on 03/05/08 was 88 feet. OVE is pumping well at 20 gpm. LEL reading on the well was 100%. OVE has been pumping the well at 17990 English to allow gas to vent out of the aquifer. |
1206103434 | 2008-03-20 | Production Wells | No Violations | On site at 10:00 am operator was running temperature log. 11:08 Segmented Bond log was started. initial findings of the log showed that there was good cement at 2000. It would be highly unlikely that gas was coming from depth with the quality of the cement. 600 and above showed cement with less density than below. Operator decided to run segmented bond log under pressure. Operator pressured 4.5 inch production pipe to 1000 psi. Baker Hughes ran segmented bond log again. 3:08 pm Segmented bond under pressure was completed. Copies of bond log were given to inspector for review. |
1211474722 | 2008-05-22 | Preliminary Restoration | No Violations | Annulus on well is open. The two valves on the 2 inch pipe away from the annulus are both in line with the pipe. No gas was noted venting from the annulus. Lease road is stable. Spoke to Ted Hill regarding reclamation of the area. Site needs graded and seeded. Gate was open, no lock on gate. 73.1 LEL at the annulus vent. |
1218736708 | 2008-08-14 | Preliminary Restoration | No Violations | On site with Wayne from Bainbridge FDP, tested LEL of the annulus space on the well. Highest LEL reading obtained was 61, using the FDPs meter. Lease road gate was locked. Vegetation is established west of the well. Final grading has not been completed. Lease road was stable. Silt fence was in place north of the well. |
1221756638 | 2008-09-18 | Preliminary Restoration | No Violations | Annulus is open. LEL at the annulus 18. Site has a covering of native vegetation. Lease road is stable. Site is stable. |
1231922454 | 2007-10-18 | Drill / Deepen / Reopen | No Violations | Pits are good, pits are in clay. Rig has moved on location. Lease road is stable. Will be spudding today. |
1241443784 | 2018-02-21 | UrbanProduction Wells | No Violations | At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the annulus and flow line was open. The well was fenced and locked. Production records for this well were current. The tank battery consisted of one 100 BBL production tank, one 50 BBL poly brine tank and a mechanical separator. Valves on the separator were open. The tank battery was diked and fenced with a locked man door. Legible signage was located at the well and tank battery and the lease access was stable. No violations observed. |
1302179542 | 2011-04-06 | Preliminary Restoration | No Violations | No change on site. Annulus is locked open. Lease road is stable. Lease road gate is locked. |
1309973728 | 2011-07-06 | Preliminary Restoration | No Violations | No change on site. Annulus is open. Lease road is stable. |
1311877885 | 2011-07-11 | Drill / Deepen / Reopen | No Violations | Tom Wood, Rick Little and Dale Neithing on site. 10:34am wellhead taken off. Fluid level 25 bubbling in the well and vapors coming off of the 4.5 inch casing was observed. 3 and 7/8 Verrel Bit and Junk/Boot basket was ran into the 4.5 inch casing. Well was plumbed into a frac tank for work over, incase of flow. Work pit has been dug and lined adjacent to the well for work over. Operator is going to trip in a test equipment make sure everything is ready for 07/12/2011. |
1314887035 | 2011-08-29 | Preliminary Restoration | No Violations | Lease road gate was locked. Lease road is stable. Tank battery consists of one 100 barrel tank and mechanical sepapator. The dike has been constructed, fencing installed, automatic shut off has been installed on tank, charcoal filter and spare arrestor are in place. Fencing has also been installed around the wellhead. Chain link fence has green privacy strips blocking view of battery. Locks are needed on the man doors of the wellhead and tank battery. Wellhead hammer union had a slight leak below the demko valve. Well is shut in. Wellhead has a rabbit catcher. Operator has seeded and mulched the graded area around the tank battery and majority of the graded area around the wellhead. Area west of the wellhead needs final grading, seeding and mulching. |
1322843590 | 2011-12-01 | UrbanPreliminary Restoration | No Violations | This well is in production. The affected area around the wellhead has been graded, seeded and vegetation is established. The wellhead has been fenced with green chain link with plastic slats and the man door was locked. The lease road is stable, constructed out of durable material and the lease road gate was locked. The man door to the tank battery was not locked during my inspection. The tank battery is properly fenced and equipped with one 100 barrel production tank, one poly brine tank and a mechincal separator. Equipment spacing is correct. The silt fence above the stream crossing can be removed at this time. There was a 1/4 copper line leaking at the fitting of the Big Joe water separator. I contacted Ted Hill and advised him of the leak. |
1326607577 | 2011-07-15 | Drill / Deepen / Reopen | No Violations | 8:36am work started. 9:58 iron bridge plug drilled out. Lost circulation for 4 minutes. Hole was static after circulation was regained. Tagged bottom of hole 3760. |
1326984130 | 2012-01-19 | UrbanProduction Wells | No Violations | No violations on site. The annulus is open and the gas leak at the 1/4 copper line has been repaired. The lease road is stable and there is an identification sign posted on the gate. Man doors are locked, locks were frozen and the dike was in good repair. |
1484918653 | 2016-11-23 | UrbanProduction Wells | No Violations | I was onsite with Emergency Operations Coordinator Fred Romeo in response to a complaint (#5470) regarding gas in a landowner water well. At the time of this inspection, this well was equipped with a plunger lift assembly and the valves on the wellhead were open. The 8 and 5/8 inch annulus was plumbed above grade, equipped with a pop-off valve and open. The pressure gauge on the annulus valve was reading zero. No issues were observed. |
171260674 | 2007-10-18 0:00 | DD | No Violations | |
1841875912 | 2012-07-09 | Production Wells | No Violations | My inspection today found the well in production. The needle gauge on the tubing read 900 psi. The 2 inch tubing on the west side of the wellhead was leaking gas at the threads. Fitting needs tightened. All man doors on location were locked. The lease road was stable. Lease road gate was locked. Operator contacted in regards to the needed repair. |
1969816142 | 2008-01-28 | Preliminary Restoration | No Violations | 10:40am on site to check annulus pressure. Annulus pressure was 25psi, pop off valve was bleeding off extra pressure. Annulus was closed off at 8:25am, and directed into the pop off valve system. On site at 12:48 30psi on needle gauge pop off valve working. Gas bubbling up around 4.5 pipe. |
1996013768 | 2011-07-14 | Drill / Deepen / Reopen | No Violations | Wellhead was broken last night while tripping, wellhead has been replaced. Hole was static at the start of the day. Cement top 2nd plug 3356 soft cement was encountered at 3349. Operator is drilling plugs out with fluid. Flow at 9:40am 3366.05 depth. Operator staked flow line down. Operator circulated on well 10:02 bottoms up show of oil. Bottoms up twice and the hole was static. 3530 bridge plug. 16:50 open hole 3626. Pressure test 4.5 inch casing. 17:15 BOP closed pump failure. 18:00 BOP closed at 1200psi. 18:04 4.5 inch casing psi 550psi, 18:06 psi 520psi, 18:10 500psi pressure bleeding at the packing. Test failed. Change over and valve placed on tubing. 18:38 BOP closed at 1450psi. 18:43 4.5 inch casing pressured to 550psi. After 20minute test zero pressure loss. |
2049506477 | 2008-04-28 | Preliminary Restoration | No Violations | Lease road is stable. Tank battery has been ruffed in. Gate was locked. Met with Mike McCormac on site. |
2101879437 | 2011-07-13 | Drill / Deepen / Reopen | No Violations | Operator is drilling cement plugs at the time of inspection. Bottom of the cement 2470. Well flowed and gas once cement was drilled out. Circulated on the well, well was static. 20min pressure test on 4.5 inch casing, 605psi for 20 minutes. Final pressure at the end of the test 575psi. Noticeable leak at the packing on the swivel. Well has a Giberson Hyd. Stripping head annular BOP. Tested at 1500psi. Operator is going to trip out, change bit and trip back in. No flow and no gas at the end of the day. |
2139852812 | 2008-11-24 | Production Wells | No Violations | Gate was locked. Snow has been on the ground for a week, no vehicle or truck tracks in the snow, foot traffic and ATV tracks only. Annulus space to the well is open. Annulus was under snow and had wet snow in it, removed snow during inspection. LEL reading was 57%LEL at the annulus. No change on site. Wagon that had sales line pipe on it has been removed. Sales line pipe still on site. Lease road is stable. Locked gate when I left the site. |
2143870535 | 2011-07-18 | Drill / Deepen / Reopen | No Violations | Operator stated when wellhead was opened there was a slight vacuum. Operator had swabbed well before inspection. Per operator, approximately 1400 of fluid removed; pull #1 100 Pull #2 200 Pulls 3 and 4 400 each #5 pulled fluid noted rise in fluid. Flowed and turned to gas with a trace of oil. Shut in pressure 400psi. |
331075441 | 2008-1-29 0:00: | PL | No Violations | |
367869179 | 2007-12-15 0:00 | DD | No Violations | |
626518353 | 2007-10-29 0:00 | DD | No Violations | |
64989375 | 2012-3-7 0:00:0 | PW | No Violations | |
729371856 | 2007-12-16 0:00 | WR | No Violations | |
770476226 | 2010-12-3 0:00: | UL | No Violations |