34-055-21999

Well Details

Well ID: 34-055-21999
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Parkman Township
Operator Name: DJR WELL SERVICES INC.
Well Pad ID:
Farm/Lease Name: YODER R UNIT
License Status: Producing
License Date: 2007-11-15
Spud Date: 2007-12-20
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2008-02-20
Well Total Depth: 4130.00 ft
Configuration: Vertical
Latitude: 41.410000
Longitude: -81.010000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-11-15 Proposed Formations:CLINTON, Issued Date:11/15/2007, Expired Date:11/14/2008 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-02-20
Construction Permit Expires 2008-11-14
Completion Report Received 2009-01-30
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-03-12 3936 4034 26
3936 4034 26
3936 4034 26

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 68211 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 WILKES ENERGY INC 5108.00 1306.00 365
2009 WILKES ENERGY INC 9324.00 968.00 365
2010 WILKES ENERGY INC 7619.00 679.00 365
2011 WILKES ENERGY INC 6290.00 501.00 365
2012 WILKES ENERGY INC 5706.00 473.00 366
2013 WILKES ENERGY INC 4714.00 345.00 365
2014 WILKES ENERGY INC 5581.00 298.00 365
2015 WILKES ENERGY INC 4907.00 223.00 365
2016 WILKES ENERGY INC 4441.00 111.00 365
2017 WILKES ENERGY INC 3246.00 111.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 WILKES ENERGY INC Brine 875 365
2009 WILKES ENERGY INC Brine 394 365
2010 WILKES ENERGY INC Brine 227 365
2011 WILKES ENERGY INC Brine 212 365
2012 WILKES ENERGY INC Brine 238 366
2013 WILKES ENERGY INC Brine 218 365
2014 WILKES ENERGY INC Brine 196 365
2015 WILKES ENERGY INC Brine 145 365
2016 WILKES ENERGY INC Brine 141 365
2017 WILKES ENERGY INC Brine 219 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1666162133 2018-10-12 0:00 PW No Violations
0071909012 2013-03-25 Production Wells No Violations The well is equipped with a pump jack. The well and tank battery are in good repair. The tank battery consists of two 100 BBL production tanks, a 50 BBL brine tank, and a mechanical separator. The load lines are all locked and have bull plugs in them. The proper identification is located on the tank battery. The lease road is in stable condition. No violations found. The tank battery and lease road are being shared with permit # 2-2014.
1198852701 2007-12-28 Drill / Deepen / Reopen No Violations Rig on location, drilling is idle, no one on site at the time of inspection. Lease road is stable and constructed out of durable material. Pits are in good repair, fluid level is 5 below grade. Site is stable and drainage is contained on site.
1432863788 2012-02-17 Preliminary Restoration No Violations Well is equippes with a pumping unit, the location has been reclaimed and identification is posted on the tank battery. The dike is in good repair. I tested Cloride levels on a seep at the east end of the tank battery. Registered 48 ppm. Spacing between the production tanks is appropriate at 36 inches.
1570468544 2019-10-7 0:00: PW No Violations 0.30
1666162133 2018-10-12 Production Wells No Violations I conducted an inspection on this well. At the time of this inspection, the well was equipped with a pumping unit and in production. There was a domestic line plumbed off of the 4.5 inch casing with a regulator, meter and drip bottle. The tank battery was comprised of two 100 BBL tanks, one 35 BBL tank and a mechanical separator. There was a domestic line plumbed off of the separator with a regulator, meter and drip bottle. The tank battery was diked and shared with well 2-2014. Legible signage was located at the well and tank battery. The lease access was stable.
71909012 2013-3-25 0:00: PW No Violations

For data sources see[9]

References