X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-22000

Well Details

Well ID: 34-055-22000
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Parkman Township
Operator Name: DJR WELL SERVICES INC.
Well Pad ID:
Farm/Lease Name: TROYER
License Status: Producing
License Date: 2007-11-16
Spud Date: 2008-01-08
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2008-01-12
Well Total Depth: 4274.00 ft
Configuration: Vertical
Latitude: 41.390000
Longitude: -81.030000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-11-16 Proposed Formations:CLINTON, Issued Date:11/16/2007, Expired Date:11/15/2008 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-01-12
Correction to Well 2008-07-03 UNIT SIZE INCREASED TO 80 ACRES.
Construction Permit Expires 2008-11-15
Completion Report Received 2009-01-30
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-03-11 4097 4156 25
4097 4156 25
4097 4156 25

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 73550 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 WILKES ENERGY INC 1715.00 1120.00 365
2009 WILKES ENERGY INC 5662.00 1138.00 365
2010 WILKES ENERGY INC 4360.00 965.00 365
2011 WILKES ENERGY INC 4095.00 691.00 365
2012 WILKES ENERGY INC 3612.00 654.00 366
2013 WILKES ENERGY INC 2402.00 367.00 365
2014 WILKES ENERGY INC 3370.00 483.00 365
2015 WILKES ENERGY INC 2345.00 450.00 365
2016 WILKES ENERGY INC 1904.00 306.00 365
2017 WILKES ENERGY INC 2046.00 350.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 WILKES ENERGY INC Brine 869 365
2009 WILKES ENERGY INC Brine 446 365
2010 WILKES ENERGY INC Brine 473 365
2011 WILKES ENERGY INC Brine 257 365
2012 WILKES ENERGY INC Brine 278 366
2013 WILKES ENERGY INC Brine 105 365
2014 WILKES ENERGY INC Brine 236 365
2015 WILKES ENERGY INC Brine 183 365
2016 WILKES ENERGY INC Brine 173 365
2017 WILKES ENERGY INC Brine 182 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-424831575 2014-11-21 0:00 PW No Violations
-460887457 2007-1-10 0:00: DD No Violations
-72316838 2013-4-4 0:00:0 PW No Violations
0072316838 2013-04-04 Production Wells No Violations My inspection found the well to be equipped with a pump jack. The annulus valve was open. The well and tank battery are in good repair. The tank battery consists of two 100 BBL production tanks, a 35 BBL brine tank, and a mechanical separator. The proper identification was on both the pump jack and the tank battery. The lease road is in stable condition. The lease road and tank battery are being shared with permit number 2-2053.
0424831575 2014-11-21 Production Wells No Violations My inspection found the well to be equipped with a pump jack. The annulus valve was open. The well and tank battery are in good repair. The tank battery consists of two 100 BBL production tanks, a 35 BBL brine tank, and a mechanical separator. The proper identification was on both the pump jack and the tank battery. The lease road is in stable condition. The lease road and tank battery are being shared with permit number 2-2053.
0460887457 2007-01-10 Drill / Deepen / Reopen No Violations Drill depth 1014. Operator drilling on air. Pits are in good condition. Lease road is stable to the site. Checked in with Ben. Operator has silt fence along the north and east side of the site. Drainage is contained on site.
1281975605 2010-08-16 Preliminary Restoration No Violations Well is a pump jack well. Tank battery has two 100BBL tanks, one 50BBL tank and a mechanical separator. There is 24 inches between production tanks operator will be contacted to correct spacing. Lease road is stable. Vegetation is established on affected area. Identification signs are posted on well and tank battery. Permit 2053 is also produced into tank battery. Dike is sufficient. Lease road is constructed out of durable material. Spacing between wellhead and tank battery is more than 50 feet. Spacing from buildings is correct.

For data sources see[9]

References