X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-22030

Well Details

Well ID: 34-055-22030
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Russell Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: BUCA
License Status: Producing
License Date: 2008-04-11
Spud Date: 2008-05-22
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-05-27
Well Total Depth: 3873.00 ft
Configuration: Vertical
Latitude: 41.500000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-04-11 Proposed Formations:CLINTON, Issued Date:4/11/2008, Expired Date:4/11/2009 6:00:00 AM, Drilling unit acres:23, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-05-27
Completion Report Received 2009-02-27
Construction Permit Expires 2009-04-11
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-04-27 3659 3714 23
3659 3714 23
3659 3714 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 71793 Gal 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC 5384.00 356.00 365
2010 CUTTER EXPLORATION INC 6822.00 143.00 365
2011 CUTTER EXPLORATION INC 3355.00 85.00 0
2012 CUTTER EXPLORATION INC 6053.00 193.00 366
2013 CUTTER EXPLORATION INC 4886.00 124.00 365
2014 CUTTER EXPLORATION INC 3624.00 53.00 365
2015 CUTTER EXPLORATION INC 3948.00 76.00 365
2016 CUTTER EXPLORATION INC 3334.00 49.00 365
2017 CUTTER EXPLORATION INC 51.00 3632.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC Brine 241 365
2010 CUTTER EXPLORATION INC Brine 195 365
2011 CUTTER EXPLORATION INC Brine 68
2012 CUTTER EXPLORATION INC Brine 65 366
2013 CUTTER EXPLORATION INC Brine 80 365
2014 CUTTER EXPLORATION INC Brine 49 365
2015 CUTTER EXPLORATION INC Brine 60 365
2016 CUTTER EXPLORATION INC Brine 0 365
2017 CUTTER EXPLORATION INC Brine 75 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1004501652 2017-2-10 0:00: UP No Violations 25.00
-1382437005 2008-5-26 0:00: DD No Violations
-1792589369 2013-5-29 0:00: UP No Violations
-235542142 2008-5-17 0:00: DD No Violations
-411984493 2011-3-17 0:00: PW No Violations
0088440900 2011-01-05 UrbanPreliminary Restoration No Violations Lease road is stable. No lease road gate, drive is primary drive to home. Two 100Bbl production tanks in the battery. Charcoal filter, spark arrestor and low pressure relief valve in place. PVC drain pipe at the south west corner of the dike, drain was open, closed during inspection. Well is a rabbit well, annulus has a 25psi pop-off annulus pressure was over 25 psi, pop-off went off during inspection. Annulus is plumbed into the charcoal filter. There is a leak on one of the 1/2 inch lines going to the control box, operator will be notified. Identification sign posted at the entrance of the site. Turn around is at the tank battery. Man door to the well needs repaired, latch is broken.
0235542142 2008-05-17 Drill / Deepen / Reopen No Violations On site by request of operator. Site has been constructed, lease road is stable and constructed out of durable material. Pull off area is stable and constructed out of durable material. Pits have been dug they are in brown clay, no ground water noted. Operator has placed drainage controls west end of affected area, drainage from affected area is directed to the west. Operator has done a very good job segregating topsoil and subsoil. Operator will be lining pit today and bring fresh water drilling mud from there other site. Asked operator to make sure safety fence is up around pits, once mud is in them.
0411984493 2011-03-17 Production Wells No Violations Annulus is vented through the charcoal filter. Annulus was actively venting. Operator has a 25psi pop-off on the annulus that releases at 27psi and allows as to vent. Annulus pressure was at 27 psi. There is a leak on a control module on the wellhead, gas was venting through the controller. Contacted operator in regards to the needed repairs.
0997477495 2011-07-06 Preliminary Restoration No Violations Affected area from drilling has been reclaimed. Well is a rabbit well, tank battery has a 2 100Bbl production tanks, 1500 gallon poly tank and a mechincal separator. Lease road is stable and constructed out of durable material. Man doors are locked. Fencing is correct. No landscaping has been installed at this time. Company will be contacted.
1004501652 2017-02-10 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced with a locked man door. The last reported production for this well was submitted in 2015. The tank battery consisted of two 100 BBL production tanks, one 50 BBL poly brine tank and a mechanical separator. The tank valves were plugged. The vent stack on the production tank is plumbed into a 55 gallon charcoal filter then plumbed up and topped with a spark arrestor. The correct lids and hatches were installed on the tanks. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the well and tank battery and the lease access was stable. No violations were observed.
1382437005 2008-05-26 Drill / Deepen / Reopen No Violations logging well 4.5 tonight
1792589369 2013-05-29 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open to a pop off valve that is plumbed into the production tank. The tank battery and well are in good repair and surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL poly brine tank, and a mechanical separator. The vent stack on the production tank is plumbed into a 55 gallon charcoal filter. The vent stack is then plumbed up and topped with a spark arrestor. The proper identification is located on the tank battery. The lease road is in stable condition.
88440900 2011-1-5 0:00:0 UL No Violations
997477495 2011-7-6 0:00:0 PL No Violations

For data sources see[9]

References