34-055-22046

Well Details

Well ID: 34-055-22046
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Russell Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: MURFELLO
License Status: Producing
License Date: 2008-05-29
Spud Date: 2008-07-13
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-07-19
Well Total Depth: 3788.00 ft
Configuration: Vertical
Latitude: 41.500000
Longitude: -81.360000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-05-29 Proposed Formations:CLINTON, Issued Date:5/29/2008, Expired Date:5/29/2009 6:00:00 AM, Drilling unit acres:22.45, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-07-19
Completion Report Received 2009-02-27
Construction Permit Expires 2009-05-29
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-05-05 3604 3651 28
3604 3651 28
3604 3651 28

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 73012 Gal 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC 18212.00 265.00 365
2010 CUTTER EXPLORATION INC 20670.00 177.00 365
2011 CUTTER EXPLORATION INC 11471.00 80.00 0
2012 CUTTER EXPLORATION INC 1773.00 66.00 366
2013 CUTTER EXPLORATION INC 7308.00 143.00 365
2014 CUTTER EXPLORATION INC 18647.00 241.00 365
2015 CUTTER EXPLORATION INC 3159.00 0.00 365
2016 CUTTER EXPLORATION INC 3223.00 65.00 365
2017 CUTTER EXPLORATION INC 0.00 2094.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC Brine 205 365
2010 CUTTER EXPLORATION INC Brine 55 365
2011 CUTTER EXPLORATION INC Brine 0
2012 CUTTER EXPLORATION INC Brine 214 366
2013 CUTTER EXPLORATION INC Brine 107 365
2014 CUTTER EXPLORATION INC Brine 198 365
2015 CUTTER EXPLORATION INC Brine 27 365
2016 CUTTER EXPLORATION INC Brine 0 365
2017 CUTTER EXPLORATION INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2047064300 2019-1-16 0:00: UP No Violations 0.40
-427058665 2009-8-26 0:00: PL No Violations
-902561751 2013-5-29 0:00: UP No Violations
0378251471 2008-08-11 Drill / Deepen / Reopen No Violations fencing up
0427058665 2009-08-26 Preliminary Restoration No Violations Lease road is stable. Vegetation is established. 13 of the planted trees are surviving, 6 have died. Well head and tank battery are fenced. Site is stable. Well is a rabbit well, tank battery has one 110 BBL tank and Mechanical separator. Filter and spark arrestors are in place.
0563330875 2017-02-06 UrbanProduction Wells No Violations At the time of this inspection, the well was observed to be equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced with a locked man door. Reported production was last submitted in 2015. The tank battery consisted of one 100 BBL production tank, one 50 BBL poly brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The vent stack on the production tank was plumbed into a 55 gallon charcoal filter then plumbed up and topped with a spark arrestor. The tank valves were equipped with flat plugs. The tank battery was diked and fenced with a locked man door. Proper, legible signage was located at the tank battery and the lease access was stable. No violations were observed.
0806965946 2014-10-17 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
0902561751 2013-05-29 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open to a pop off valve that is plumbed into the production tank. The tank battery and well are in good repair and surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 50 BBL poly brine tank, and a mechanical separator. The vent stack on the production tank is plumbed into a 55 gallon charcoal filter. The vent stack is then plumbed up and topped with a spark arrestor. The proper identification is located on the tank battery. The lease road is in stable condition.
1219064490 2008-07-15 Drill / Deepen / Reopen No Violations surface
1288191745 2010-10-27 UrbanPreliminary Restoration No Violations Lease road is stable. Vegetation and landscaping is established. Fencing is correct. Spacing is correct. Tank battery has charcoal filter and spark arrestor on it. Operator has removed the bull plug from the top of the tank and hard plumbed an overflow from the 100Bbl tank into the poly tank. Plumbing needs to be removed. Identification sign is posted. Danger keep away sign posted. DOT sticker posted. Production tank number 39519. Man doors are locked. Load lines are inside the dike. Dike is in good repair.
1403013275 2008-10-14 Drill / Deepen / Reopen No Violations Well is a rabbit well. Site has been ruff graded. Tank battery is under construction. Current spacing is good. Landscape trees are on site for screening. Lease road is stable and in good repair. Annulus pop off has popped off. Pressure reading is 28psi, gas was venting from the annulus.
2047064300 2019-01-16 UrbanProduction Wells No Violations I conducted an inspection on this well. The well was equipped with a plunger lift assembly and in production during this inspection. The well was fenced with a locked man door. The tank battery was comprised of one 100 BBL tank, one 50 BBL tank and a mechanical separator. Valves on the separator were open. The production tank vent stack was plumbed into a 55 gallon charcoal filter then plumbed up and topped with a spark arrestor. Tank valves were equipped with plugs. There was a Dominion East Ohio master meter located within the diked tank battery. The tank battery was fenced with a locked man door. Legible identification was present at the well and tank battery and the lease access was stable.
2073935381 2011-03-02 Production Wells No Violations On site with the Mark the pumper for the well. Mark has concerns in regards to Dominions meter runs. Per Mark, Dominion is depending on two pressure regulators for pressure control on the sales lines on there new meter runs. Old meter runs used to have one pressure regulator and a pop-off after the meter. Per Mark the regulators are prone to freezing due to condensation. I informed Mark, that meter runs are not under the DMRMs jurisdiction. I informed Mark that I would notify my supervisors of the companies concerns. Neighborhood in the area of Murfello #1 had the gas shut down due to oil in the Dominion sales line. No violations found at the Murfello #1.
378251471 2008-8-11 0:00: DD No Violations
563330875 2017-2-6 0:00:0 UP No Violations
806965946 2014-10-17 0:00 UP No Violations

For data sources see[9]