Well ID: 34-055-22053 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.39,"lon":-81.03,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Parkman Township | |
Operator Name: DJR WELL SERVICES INC. | |
Well Pad ID: | |
Farm/Lease Name: TROYER UNIT | |
License Status: Producing | |
License Date: 2008-07-01 | |
Spud Date: 2008-07-22 | |
Spud Drilling Contractor: WHIPSTOCK OHIO DRILLING | |
Final Drill Date: 2008-07-26 | |
Well Total Depth: 4304.00 ft | |
Configuration: Vertical | |
Latitude: 41.390000 | |
Longitude: -81.030000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-07-01 | Proposed Formations:CLINTON, Issued Date:7/1/2008, Expired Date:7/1/2009 6:00:00 AM, Drilling unit acres:80, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-07-26 | |
Completion Report Received | 2009-01-30 | |
Construction Permit Expires | 2009-07-01 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-03-12 | 4073 | 4146 | 20 |
4073 | 4146 | 20 | |
4073 | 4146 | 20 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 69000 Gal | 40000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | WILKES ENERGY INC | 0.00 | 0.00 | 0 |
2009 | WILKES ENERGY INC | 5662.00 | 1138.00 | 365 |
2010 | WILKES ENERGY INC | 4360.00 | 965.00 | 365 |
2011 | WILKES ENERGY INC | 4095.00 | 691.00 | 365 |
2012 | WILKES ENERGY INC | 3612.00 | 654.00 | 366 |
2013 | WILKES ENERGY INC | 2402.00 | 367.00 | 365 |
2014 | WILKES ENERGY INC | 3370.00 | 483.00 | 365 |
2015 | WILKES ENERGY INC | 2344.00 | 450.00 | 365 |
2016 | WILKES ENERGY INC | 1904.00 | 306.00 | 365 |
2017 | WILKES ENERGY INC | 2046.00 | 350.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | WILKES ENERGY INC | Brine | 0 | 0 |
2009 | WILKES ENERGY INC | Brine | 446 | 365 |
2010 | WILKES ENERGY INC | Brine | 474 | 365 |
2011 | WILKES ENERGY INC | Brine | 257 | 365 |
2012 | WILKES ENERGY INC | Brine | 278 | 366 |
2013 | WILKES ENERGY INC | Brine | 105 | 365 |
2014 | WILKES ENERGY INC | Brine | 236 | 365 |
2015 | WILKES ENERGY INC | Brine | 183 | 365 |
2016 | WILKES ENERGY INC | Brine | 173 | 365 |
2017 | WILKES ENERGY INC | Brine | 182 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1098909014 | 2008-7-28 0:00: | PL | No Violations | |
-1751589560 | 2014-11-21 0:00 | PW | No Violations | |
-769410768 | 2008-7-23 0:00: | DD | No Violations | |
0769410768 | 2008-07-23 | Drill / Deepen / Reopen | No Violations | I performed a rig inspection. The drilling pit liners were in good shape. The location was in good shape, muddy. I found no violations at this time. |
0888984157 | 2013-04-04 | Production Wells | No Violations | My inspection found the well to be equipped with a pump jack. The annulus valve was open. The well and tank battery are in good repair. The tank battery consists of two 100 BBL production tanks, a 35 BBL brine tank, and a mechanical separator. The proper identification was on both the pump jack and the tank battery. The lease road is in stable condition. The lease road and tank battery are being shared with permit number 2-2000. |
1098909014 | 2008-07-28 | Preliminary Restoration | No Violations | I performed a preliminary restoration status check. I GPSd the well. The pit fluid was down 3 foot and the pit liners were in good shape. The drilling rig was gone and the debris was gone. This well has not passed preliminary restoration. |
1216983627 | 2008-07-23 | Drill / Deepen / Reopen | No Violations | I witnessed the cementing of the 8 5/8 casing. I found no violations at this time. |
1751589560 | 2014-11-21 | Production Wells | No Violations | My inspection found the well to be equipped with a pump jack. The annulus valve was open. The well and tank battery are in good repair. The tank battery consists of two 100 BBL production tanks, a 35 BBL brine tank, and a mechanical separator. The proper identification was on both the pump jack and the tank battery. The lease road is in stable condition. The lease road and tank battery are being shared with permit number 2-2000. |
888984157 | 2013-4-4 0:00:0 | PW | No Violations |
For data sources see[9]