Well ID: 34-055-22076 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.5,"lon":-81.38,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Russell Township | |
Operator Name: CUTTER EXPLORATION INC | |
Well Pad ID: | |
Farm/Lease Name: SKIRBUNT | |
License Status: Producing | |
License Date: 2008-10-29 | |
Spud Date: 2008-12-15 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2008-12-20 | |
Well Total Depth: 3736.00 ft | |
Configuration: Vertical | |
Latitude: 41.500000 | |
Longitude: -81.380000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-10-29 | Proposed Formations:CLINTON, Issued Date:10/29/2008, Expired Date:10/29/2009 6:00:00 AM, Drilling unit acres:22.72, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-12-20 | |
Construction Permit Expires | 2009-10-29 | |
Completion Report Received | 2009-11-20 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-02-03 | 3549 | 3608 | 24 |
3549 | 3608 | 24 | |
3549 | 3608 | 24 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 70692 Gal | 25000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | CUTTER EXPLORATION INC | 2038.00 | 85.00 | 365 |
2010 | CUTTER EXPLORATION INC | 15236.00 | 364.00 | 365 |
2011 | CUTTER EXPLORATION INC | 22090.00 | 261.00 | 0 |
2012 | CUTTER EXPLORATION INC | 17823.00 | 66.00 | 366 |
2013 | CUTTER EXPLORATION INC | 11035.00 | 126.00 | 365 |
2014 | CUTTER EXPLORATION INC | 9049.00 | 73.00 | 365 |
2015 | CUTTER EXPLORATION INC | 8534.00 | 75.00 | 365 |
2016 | CUTTER EXPLORATION INC | 6415.00 | 79.00 | 365 |
2017 | CUTTER EXPLORATION INC | 60.00 | 2386.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | CUTTER EXPLORATION INC | Brine | 790 | 365 |
2010 | CUTTER EXPLORATION INC | Brine | 240 | 365 |
2011 | CUTTER EXPLORATION INC | Brine | 107 | |
2012 | CUTTER EXPLORATION INC | Brine | 35 | 366 |
2013 | CUTTER EXPLORATION INC | Brine | 70 | 365 |
2014 | CUTTER EXPLORATION INC | Brine | 65 | 365 |
2015 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2016 | CUTTER EXPLORATION INC | Brine | 51 | 365 |
2017 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1041552203 | 2010-8-20 0:00: | PW | No Violations | |
-1109767058 | 2008-12-16 0:00 | DD | No Violations | |
-1401537093 | 2008-12-30 0:00 | DD | No Violations | |
-1819091371 | 2009-10-19 0:00 | PL | No Violations | |
-886098202 | 2013-3-7 0:00:0 | PW | No Violations | |
0000345620 | 2017-02-06 | UrbanProduction Wells | No Violations | At the time of this inspection, the well was observed to be equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced and locked. The last reported production for this well was submitted in 2015. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The separator union valves were seeping some oil and needed to be tightened up. The tank valves were equipped with flat plugs. The vent stack on the production tank was plumbed into a 55 gallon charcoal filter then plumbed up and topped with a spark arrestor. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery. The lease access was stable. I called and spoke with Mark Turpak of Cutter about the leaking hammer unions and getting those tightened. |
0139510475 | 2011-12-01 | UrbanProduction Wells | No Violations | The wellhead is in good repair and the man doors on well and tank battery were locked. The landscaping is established and proper identification is posted on site. The lease road is stable and constructed out of durable material. |
0225244566 | 2014-08-13 | UrbanProduction Wells | No Violations | My inspection found no changes since my last inspection. No violations found. |
0567252284 | 2017-03-30 | UrbanProduction Wells | No Violations | I conducted a reinspection on this well site with regards to a leaking hammer union on the separator line. The the well was observed to be equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced and locked. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The separator union valve was no longer seeping and has been repaired. The tank valves were equipped with flat plugs. The vent stack on the production tank was plumbed into a 55 gallon charcoal filter then plumbed up and topped with a spark arrestor. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery. The lease access was stable. No violations were observed. |
0886098202 | 2013-03-07 | Production Wells | No Violations | I conducted an inspection pursuant to a call from a landowner indicating a suspected release of oil from the unit into Dominion/East Ohio (Dominion) gas transmission lines. Reportedly, several homes located near the intersection of Cedar Road and County Line Road had gas service interruption due to oil accumulation in the line, at the meters. Prior to arrival, I was contacted by Gates Mills Fire Chief Tom Robinson, and I indicated to him that ODNR was aware of the report, and I was responding to the site. Also, prior to my arrival, I contacted Mike with Cutter Exploration (Cutter) and advised him of the report, and he indicated that he would in turn contact his service person. Upon arrival I encountered service crews from Dominion working to restore service at the affected homes. They indicated that they had shut off the service connection at the metering run. After my arrival Mark from Cutter arrived to evaluate the situation. He indicated that the producing unit had been returned to service within the last week, and only began producing fluid yesterday (3/6). He thinks that there may have been residual oil in the line between the mechanical separator and the metering run which got kicked into the service line. Based on my discussions with Mike and Mark, they will keep the unit offline until they add one or more additional pressure shut offs. The Dominion crews were able to re-establish service at the five affected homes at around 5:30 PM. I told Mike that we would follow up and confirm that the problem was corrected prior to returning the unit to service. |
1041552203 | 2010-08-20 | Production Wells | No Violations | 100BBL and 50BBL tanks in battery. Spacing, fence, filters, arrestors are all within HB-278 and ORC 1514 requirements. Load lines are inside dike. ID sign is posted. Man doors are locked. Annulus pressure 5 psi. Vegetation and landscaping are outstanding. |
1109767058 | 2008-12-16 | Drill / Deepen / Reopen | No Violations | On site for surface cement. Job went well, mixed cement until it return to surface. Top of Berea was 170 bottom 210, operator set pipe at 275. |
1168954010 | 2013-02-07 | Production Wells | No Violations | |
1229027733 | 2008-12-11 | Drill / Deepen / Reopen | No Violations | Site has been cut. Operator was dig pits at the time of inspection. Ground water was flowing into pits, instructed Mr. Palmer (equipment operator on site,) to back fill pits with clay until water is closed off. Clay will need to be compacted to isolate ground water. Pits will need to be coated with bentonite clay before pits are lined. Permit ID sign is up. Silt fence is in place. Operator has taken topsoil and overburden to the south and southeast side of the site. Safety fence is up. Rock apron is being installed. |
1230571232 | 2008-12-29 | Drill / Deepen / Reopen | No Violations | On site for pit closer. Operator was pulling fluid out of the pits by Pander Trucking. Two loads of cement on site. Road broom on site, operator was cleaning road, as needed. |
1231766533 | 2009-01-07 | Drill / Deepen / Reopen | No Violations | Pits have been closed. Site is stable and in good repair. |
1233693037 | 2009-02-02 | Drill / Deepen / Reopen | No Violations | Pits have been closed. Frac tanks being unloaded at site. Site is stable. |
1282701124 | 2016-05-12 | UrbanProduction Wells | No Violations | My inspection found the company has installed a chain and a lock on the fence man doors. No other changes since my last inspection. |
1303743552 | 2008-12-15 | Drill / Deepen / Reopen | No Violations | Requested company to get a road broom on site, ASAP. Water trucks had tracked rock and mud onto road. On site for CND job, job went well. 60sacks of cement, mixed cement till it returned to surface then displaced. |
1316292918 | 2008-12-10 | Drill / Deepen / Reopen | No Violations | Site has been cut. Operator was installing silt fence at the drainage swale. Road apron was under construction. Permit sign was posted. Crew installing silt fence was planning on going to permit 2077, to repair drainage controls. |
1353937040 | 2011-07-13 | Preliminary Restoration | No Violations | Plumbing from the side of the production tank into the poly tank needs removed. Plumbing circumvents safety equipment. Locks are on man doors and load lines. 24 psi on the annulus, annulus has a pop-off. Lease road is stable. Reclamation has been completed. |
139510475 | 2011-12-1 0:00: | UP | No Violations | |
1401537093 | 2008-12-30 | Drill / Deepen / Reopen | No Violations | Operator on site waiting for 3rd load of cement. Pits had two loads of cement mixed into them 12/29/2008. Third load was needed. Site is stable. |
1413824881 | 2014-10-20 | UrbanProduction Wells | No Violations | My inspection found no changes since my last inspection. No violations found. |
1547652446 | 2019-01-16 | UrbanProduction Wells | No Violations | I conducted an inspection on this well regarding complaint # 6055, involving stressed vegetation on the complaintants property. The complaintant/landowner was concerned that the stressed vegetation may be related to the gas well on his property. At the time of this inspection, the well was equipped with a plunger lift assembly and in production. No leaks or odors were observed at the well location. The well was fenced with a locked man door. The tank battery was comprised of one 100 BBL tank, one 50 BBL tank and a mechanical separator. Valves on the separator were open. The tank valves were equipped with plugs and the vent stack on the 100 BBL tank was plumbed into a 55 gallon charcoal filter, then plumbed up and topped with a spark arrestor. The diked tank battery was fenced with a locked man door. No leaks were observed at the tank battery location. Legible identification was present at the tank battery and the lease access was stable. |
1819091371 | 2009-10-19 | Preliminary Restoration | No Violations | Well site is in good repair. Lease road is stable. Well and tank battery is fenced. Landscaping is up. Operator used the mulch from clearing to mulch dike around tank battery, this will help prevent erosion. Vegetation is established. Identification sign is up on tank battery. One 140 BBL and on 50BBL tank in battery. |
225244566 | 2014-8-13 0:00: | UP | No Violations | |
345620 | 2017-2-6 0:00:0 | UP | No Violations | 25.00 |
567252284 | 2017-3-30 0:00: | UP | No Violations |