34-055-22076

Well Details

Well ID: 34-055-22076
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Russell Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: SKIRBUNT
License Status: Producing
License Date: 2008-10-29
Spud Date: 2008-12-15
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-12-20
Well Total Depth: 3736.00 ft
Configuration: Vertical
Latitude: 41.500000
Longitude: -81.380000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-10-29 Proposed Formations:CLINTON, Issued Date:10/29/2008, Expired Date:10/29/2009 6:00:00 AM, Drilling unit acres:22.72, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-12-20
Construction Permit Expires 2009-10-29
Completion Report Received 2009-11-20
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-02-03 3549 3608 24
3549 3608 24
3549 3608 24

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 70692 Gal 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC 2038.00 85.00 365
2010 CUTTER EXPLORATION INC 15236.00 364.00 365
2011 CUTTER EXPLORATION INC 22090.00 261.00 0
2012 CUTTER EXPLORATION INC 17823.00 66.00 366
2013 CUTTER EXPLORATION INC 11035.00 126.00 365
2014 CUTTER EXPLORATION INC 9049.00 73.00 365
2015 CUTTER EXPLORATION INC 8534.00 75.00 365
2016 CUTTER EXPLORATION INC 6415.00 79.00 365
2017 CUTTER EXPLORATION INC 60.00 2386.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC Brine 790 365
2010 CUTTER EXPLORATION INC Brine 240 365
2011 CUTTER EXPLORATION INC Brine 107
2012 CUTTER EXPLORATION INC Brine 35 366
2013 CUTTER EXPLORATION INC Brine 70 365
2014 CUTTER EXPLORATION INC Brine 65 365
2015 CUTTER EXPLORATION INC Brine 0 365
2016 CUTTER EXPLORATION INC Brine 51 365
2017 CUTTER EXPLORATION INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1041552203 2010-8-20 0:00: PW No Violations
-1109767058 2008-12-16 0:00 DD No Violations
-1401537093 2008-12-30 0:00 DD No Violations
-1819091371 2009-10-19 0:00 PL No Violations
-886098202 2013-3-7 0:00:0 PW No Violations
0000345620 2017-02-06 UrbanProduction Wells No Violations At the time of this inspection, the well was observed to be equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced and locked. The last reported production for this well was submitted in 2015. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The separator union valves were seeping some oil and needed to be tightened up. The tank valves were equipped with flat plugs. The vent stack on the production tank was plumbed into a 55 gallon charcoal filter then plumbed up and topped with a spark arrestor. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery. The lease access was stable. I called and spoke with Mark Turpak of Cutter about the leaking hammer unions and getting those tightened.
0139510475 2011-12-01 UrbanProduction Wells No Violations The wellhead is in good repair and the man doors on well and tank battery were locked. The landscaping is established and proper identification is posted on site. The lease road is stable and constructed out of durable material.
0225244566 2014-08-13 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
0567252284 2017-03-30 UrbanProduction Wells No Violations I conducted a reinspection on this well site with regards to a leaking hammer union on the separator line. The the well was observed to be equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced and locked. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The separator union valve was no longer seeping and has been repaired. The tank valves were equipped with flat plugs. The vent stack on the production tank was plumbed into a 55 gallon charcoal filter then plumbed up and topped with a spark arrestor. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery. The lease access was stable. No violations were observed.
0886098202 2013-03-07 Production Wells No Violations I conducted an inspection pursuant to a call from a landowner indicating a suspected release of oil from the unit into Dominion/East Ohio (Dominion) gas transmission lines. Reportedly, several homes located near the intersection of Cedar Road and County Line Road had gas service interruption due to oil accumulation in the line, at the meters. Prior to arrival, I was contacted by Gates Mills Fire Chief Tom Robinson, and I indicated to him that ODNR was aware of the report, and I was responding to the site. Also, prior to my arrival, I contacted Mike with Cutter Exploration (Cutter) and advised him of the report, and he indicated that he would in turn contact his service person. Upon arrival I encountered service crews from Dominion working to restore service at the affected homes. They indicated that they had shut off the service connection at the metering run. After my arrival Mark from Cutter arrived to evaluate the situation. He indicated that the producing unit had been returned to service within the last week, and only began producing fluid yesterday (3/6). He thinks that there may have been residual oil in the line between the mechanical separator and the metering run which got kicked into the service line. Based on my discussions with Mike and Mark, they will keep the unit offline until they add one or more additional pressure shut offs. The Dominion crews were able to re-establish service at the five affected homes at around 5:30 PM. I told Mike that we would follow up and confirm that the problem was corrected prior to returning the unit to service.
1041552203 2010-08-20 Production Wells No Violations 100BBL and 50BBL tanks in battery. Spacing, fence, filters, arrestors are all within HB-278 and ORC 1514 requirements. Load lines are inside dike. ID sign is posted. Man doors are locked. Annulus pressure 5 psi. Vegetation and landscaping are outstanding.
1109767058 2008-12-16 Drill / Deepen / Reopen No Violations On site for surface cement. Job went well, mixed cement until it return to surface. Top of Berea was 170 bottom 210, operator set pipe at 275.
1168954010 2013-02-07 Production Wells No Violations
1229027733 2008-12-11 Drill / Deepen / Reopen No Violations Site has been cut. Operator was dig pits at the time of inspection. Ground water was flowing into pits, instructed Mr. Palmer (equipment operator on site,) to back fill pits with clay until water is closed off. Clay will need to be compacted to isolate ground water. Pits will need to be coated with bentonite clay before pits are lined. Permit ID sign is up. Silt fence is in place. Operator has taken topsoil and overburden to the south and southeast side of the site. Safety fence is up. Rock apron is being installed.
1230571232 2008-12-29 Drill / Deepen / Reopen No Violations On site for pit closer. Operator was pulling fluid out of the pits by Pander Trucking. Two loads of cement on site. Road broom on site, operator was cleaning road, as needed.
1231766533 2009-01-07 Drill / Deepen / Reopen No Violations Pits have been closed. Site is stable and in good repair.
1233693037 2009-02-02 Drill / Deepen / Reopen No Violations Pits have been closed. Frac tanks being unloaded at site. Site is stable.
1282701124 2016-05-12 UrbanProduction Wells No Violations My inspection found the company has installed a chain and a lock on the fence man doors. No other changes since my last inspection.
1303743552 2008-12-15 Drill / Deepen / Reopen No Violations Requested company to get a road broom on site, ASAP. Water trucks had tracked rock and mud onto road. On site for CND job, job went well. 60sacks of cement, mixed cement till it returned to surface then displaced.
1316292918 2008-12-10 Drill / Deepen / Reopen No Violations Site has been cut. Operator was installing silt fence at the drainage swale. Road apron was under construction. Permit sign was posted. Crew installing silt fence was planning on going to permit 2077, to repair drainage controls.
1353937040 2011-07-13 Preliminary Restoration No Violations Plumbing from the side of the production tank into the poly tank needs removed. Plumbing circumvents safety equipment. Locks are on man doors and load lines. 24 psi on the annulus, annulus has a pop-off. Lease road is stable. Reclamation has been completed.
139510475 2011-12-1 0:00: UP No Violations
1401537093 2008-12-30 Drill / Deepen / Reopen No Violations Operator on site waiting for 3rd load of cement. Pits had two loads of cement mixed into them 12/29/2008. Third load was needed. Site is stable.
1413824881 2014-10-20 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
1547652446 2019-01-16 UrbanProduction Wells No Violations I conducted an inspection on this well regarding complaint # 6055, involving stressed vegetation on the complaintants property. The complaintant/landowner was concerned that the stressed vegetation may be related to the gas well on his property. At the time of this inspection, the well was equipped with a plunger lift assembly and in production. No leaks or odors were observed at the well location. The well was fenced with a locked man door. The tank battery was comprised of one 100 BBL tank, one 50 BBL tank and a mechanical separator. Valves on the separator were open. The tank valves were equipped with plugs and the vent stack on the 100 BBL tank was plumbed into a 55 gallon charcoal filter, then plumbed up and topped with a spark arrestor. The diked tank battery was fenced with a locked man door. No leaks were observed at the tank battery location. Legible identification was present at the tank battery and the lease access was stable.
1819091371 2009-10-19 Preliminary Restoration No Violations Well site is in good repair. Lease road is stable. Well and tank battery is fenced. Landscaping is up. Operator used the mulch from clearing to mulch dike around tank battery, this will help prevent erosion. Vegetation is established. Identification sign is up on tank battery. One 140 BBL and on 50BBL tank in battery.
225244566 2014-8-13 0:00: UP No Violations
345620 2017-2-6 0:00:0 UP No Violations 25.00
567252284 2017-3-30 0:00: UP No Violations

For data sources see[9]

References