X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-22088

Well Details

Well ID: 34-055-22088
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: MANDALFINO
License Status: Producing
License Date: 2009-03-19
Spud Date: 2009-04-14
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2009-04-20
Well Total Depth: 3825.00 ft
Configuration: Vertical
Latitude: 41.530000
Longitude: -81.320000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-03-19 Proposed Formations:CLINTON, Issued Date:3/19/2009, Expired Date:3/19/2010 6:00:00 AM, Drilling unit acres:41.03, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-04-20
Completion Report Received 2009-06-23
Construction Permit Expires 2010-03-19
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-07-20 3669 3693 22
3669 3693 22
3669 3693 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 68000 Gal 47000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC 1523.00 0.00 365
2010 CUTTER EXPLORATION INC 28488.00 190.00 365
2011 CUTTER EXPLORATION INC 13861.00 252.00 0
2012 CUTTER EXPLORATION INC 9495.00 122.00 366
2013 CUTTER EXPLORATION INC 8555.00 122.00 365
2014 CUTTER EXPLORATION INC 11560.00 95.00 365
2015 CUTTER EXPLORATION INC 4409.00 48.00 365
2016 CUTTER EXPLORATION INC 340.00 0.00 365
2017 CUTTER EXPLORATION INC 44.00 3868.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC Brine 1611 365
2010 CUTTER EXPLORATION INC Brine 214 365
2011 CUTTER EXPLORATION INC Brine 234
2012 CUTTER EXPLORATION INC Brine 82 366
2013 CUTTER EXPLORATION INC Brine 60 365
2014 CUTTER EXPLORATION INC Brine 110 365
2015 CUTTER EXPLORATION INC Brine 30 365
2016 CUTTER EXPLORATION INC Brine 0 365
2017 CUTTER EXPLORATION INC Brine 40 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1305416604 2013-6-11 0:00: UP No Violations
-1395407141 2011-6-2 0:00:0 PW No Violations
-1626071386 2013-10-22 0:00 UP No Violations
-1695243043 2011-1-26 0:00: PW No Violations
-681169222 2010-4-21 0:00: PL No Violations
-874113264 2009-4-20 0:00: DD No Violations
0079323215 2013-02-12 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The well head was surrounded by a wooden fence that was locked. The annulus was open to a pop off valve and was plumbed into the vent line for a charcoal filter. The tank battery was surrounded by a locked wooden fence and a proper dike. The tank battery consists of four 100 barrel production tanks, a 50 barrel poly tank, and two mechanical separators. The vent pipes on the productions tanks were run to two 55 gallon barrel charcoal filters. The tank battery is being shared with permit number 2-2123. The proper identification sign is on the tank battery for permit number 2-2088, but there was no sign on location for the tanks and separator for permit number 2-2123. The lease road is in good condition.
0173905403 2009-04-29 Drill / Deepen / Reopen No Violations Pit solidification, two loads in, starting to firm up. Site is stable zero psi on annulus.
0617579658 2009-05-20 Administrative Inspection No Violations E-mail from Warren Shoenfelt stating 5 day annulus test results: zero psi.
0681169222 2010-04-21 Preliminary Restoration No Violations Vegetation is sparse, affected area needs to be repair seeded or lime and fertilized added per a soil test to support vegetation. Area is stable and no erosion noted. Lease road is stable and in good repair. Identification sign is posted. Man doors were locked. Board on board fencing has been installed around battery and well, well head has been caged. Fence was in good repair. Landscaping is not sufficient at this, contacted Warren Schonfelt 4 or 5 small pine trees are not sufficient for visual barrier. Additional landscaping needs to be added to the site. Lease road gate needs installed. Sent Mike Cutter an e-mail informing him of additional work needed on location.
0874113264 2009-04-20 Drill / Deepen / Reopen No Violations Pits are in good repair. Lease road is stable. Well has been TD operator was circulating hole and conditioning it for long string.
1239820474 2009-04-14 Drill / Deepen / Reopen No Violations On site for CND job. Drift in area was 67 feet. Hole was 15 inch, pipe was new R-3 32 lb pipe 81 of pipe set. Operator broke circulation ran cement. Operator mixed cement until it returned to surface, then displaced. Cement held at surface. Safety fence was in place. Permit was posted in the dog house.
1239822412 2009-04-13 Drill / Deepen / Reopen No Violations On site for pit construction and rig move in. Subsoil for the pit was clay. No ground water noted, soil was dry. Lease road was stable and constructed out of durable material. Company sign was posted.
1242744672 2009-04-22 Drill / Deepen / Reopen No Violations On site regarding company losing logging tool down hole: The following people were on site: Poulson Drilling, Eric and Roy Poulson, Cutter, Warren Schonfelt, Superior, Marty Cominin (412) 260-9040 Lous Sesnia (724) 840-8541 Shane Russell (724) 840-7068 Shane had survey meter with him. Was monitoring site, set up a boundary if any readings no one not bagged will not be allowed in area, in the event of contamination. David Lewis, field Engineer (304) 377-0319. Todd Mobley, Director of Technical Services Applied Health Physics, Tom Hill ODNR DMRM, Norburt Lowder ODNR DMRM. The following people and agencies were contacted: NRC Satter Lodhi (610) 337-5364 Donna Jenda (610) 337-5371. Ohio Department of Health Steve James (614) 644-2727, Mike Senee (614) 644-2727. During logging, logging tool was differentially hung in hole, when attempting to retrieve tool, cable partied. Lost logging toll down hole Monday 04/20/2009. Operator has made three trips to retrieve tool. Tool parted, retrieved density tool, source and source pad still in hole. Operator advised to contact NRC. Spoke with Sattar Lodhi from NRC, Ohio is an agreement state, contact the Ohio Department of Health. Ohio Department of Health has Jurisdiction, spoke with Steve James ODH advised Steve we are planning on running in with a magnet to retrieve remainder of tool. Steve is going to contact supervisor will call back, waited for return call before running in for fourth trip. Operator has made three attempts to retrieve tool. It was agreed running in for a fourth trip would risk damaging the remainder of the tool. Superior has been monitoring the hole and circulation for radiation nothing but back ground has been detected. It was agreed to cement source and source pad in place rather than continue to attempt to retrieve it and possible break source open. Mike Senee ODH approved a 60 cement plug between source and bottom of production casing. A whip stock must be put into place. Whip stock u
1247856664 2009-04-22 Administrative Inspection No Violations Had to leave site, Norburt Lowder had to take over. These are notes given to me by Norburt Lowder: Tom Hill left site I covered the 4.5 cement job. 4.5 set at- Well TD 3825 with logging tool source at TD 3824 Procedure dictated by Ohio Dept of Health, Mike Snee. Todd Mobley on site consultant for Superior Well Service as there RAD safety person. Procedure as follows use 7 7/8 bit wielded to stub of 4.5 approx 12 collar then latch down plug, then 4.5 casing. 1 run to bottom 3815 to set 51 of cement. Mixed and pumped 50 Sk of cement pulled up to 3765 washed 4.5 then cement to 2678 approx 210 sks 58 BBl displacement, 700 fill up. Log to 3824 hot. Lockport 3142 log. Good circulation. Pipe was 4.5, 11.60lb new. Should be noted 50 sack of Class As yield is 1.18cuft: 50sacksX 1.18= 59cuft. 7 and 7/8 hole is .3382 per ln ft. 59cuft/.3382= 174 of fill up.
1288185570 2010-10-27 Production Wells No Violations Well and tank battery are in good repair. 3 out of the 5 white pines planted by the company have died, 3 of the 4 spruce planted have died. Neighbor has requested trees to be replaced. Company will be contacted to replace trees. Contacted company they will be working on replacing trees when they reclaim Mandalfino #2.
1305416604 2013-06-11 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve was open to a pop off valve and was then plumbed into the production tank. The well and tank battery are in good condition and are surrounded by a wooden fence. The tank battery consists of two 200 BBL production tanks, two 100 BBL brine tanks, a 50 BBL poly brine tank, and two mechanical separators. The vents on the production tanks are plumbed into two 55 gallon charcoal filters and then up to spark arrestors. The proper identification is located on the tank battery. The lease road is in stable condition. The lease road and tank battery are being shared by permit number 2-2123.
1395407141 2011-06-02 Production Wells No Violations On site due to a water well complaint in the area. Annulus has a pop-off installed on it and a gauge. Annulus psi was 19. Operator has replaced landscaping that did not survive, landscaping is in good repair. Operator has installed a cable across the lease road. Well is caged. Well is a rabbit well, rabbit catcher is red and has wielded fittings. Man door to the well was locked. Tank battery has two man doors. One man door is in need of a lock. Operator will be contacted in regards to lock.
1453142248 2009-05-06 Administrative Inspection No Violations Call from Warren, from Cutter, annulus psi is zero.
1481896940 2016-11-28 UrbanProduction Wells No Violations I conducted an inspection on this well. The well is equipped with a plunger lift assembly and the valves on the wellhead were open. The last submitted production records for this well was in 2015. The well was fenced and locked. The tank battery consisted of four 100 BBL tanks, one 50 BBL poly brine tank, and two mechanical separators. The valves on the separators were open and the charts showed production. There were proper lids and hatches on the production tanks. Spark arrestors were installed on the productions tanks and a charcoal filter was plumbed into the vent stack. The tank battery was diked and fenced with a locked man door. The tank battery is shared with well 2-2123. Signage needs to be updated at the tank battery to reflect information on both wells and signage needs added to each well location. The lease access was stable. I contacted Mark Turpak of Cutter Exploration about updating and installing signage at the well and tank battery locations.
1626071386 2013-10-22 UrbanProduction Wells No Violations I was on location with Tom Hill. My inspection found no changes since my last inspection.
1695243043 2011-01-26 Production Wells No Violations Operator is adding onto the tank battery. The Mandalfina #2 will be produced into the battery. Scott Miller on site working on the battery. I gave Scott Miller a copy of the Oil and Gas laws and rules while on inspection. Scott knows that a battery with two or more tanks in it and is fenced will need two man doors at either end of the battery. Went over spacing with Scott. Operator will be replacing landscaping that has died.
173905403 2009-4-29 0:00: DD No Violations
1822008455 2017-05-30 UrbanProduction Wells No Violations I conducted a reinspection on this well regarding installation of signage at the well site. The signage has been installed at the site and no violations were observed.
617579658 2009-5-20 0:00: AM No Violations
79323215 2013-2-12 0:00: PW No Violations

For data sources see[9]

References