If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-055-22121 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.51,"lon":-81.34,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Chester Township | |
Operator Name: CUTTER EXPLORATION INC | |
Well Pad ID: | |
Farm/Lease Name: GCC | |
License Status: Producing | |
License Date: 2010-03-23 | |
Spud Date: 2010-09-04 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2010-09-10 | |
Well Total Depth: 3804.00 ft | |
Configuration: Vertical | |
Latitude: 41.510000 | |
Longitude: -81.340000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2010-03-23 | Proposed Formations:CLINTON, Issued Date:3/23/2010, Expired Date:3/23/2011 6:00:00 AM, Drilling unit acres:54.45, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2010-09-10 | |
Completion Report Received | 2010-10-21 | |
Construction Permit Expires | 2011-03-23 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-12-13 | 3624 | 3695 | 33 |
3624 | 3695 | 33 | |
3624 | 3695 | 33 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2010-10-05 | H2O | 15 | 65000 Gal | 45000 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | CUTTER EXPLORATION INC | 7200.00 | 167.00 | 366 |
2013 | CUTTER EXPLORATION INC | 8133.00 | 0.00 | 365 |
2014 | CUTTER EXPLORATION INC | 2526.00 | 81.00 | 365 |
2015 | CUTTER EXPLORATION INC | 1384.00 | 81.00 | 365 |
2016 | CUTTER EXPLORATION INC | 2604.00 | 0.00 | 365 |
2017 | CUTTER EXPLORATION INC | 0.00 | 1930.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | CUTTER EXPLORATION INC | Brine | 162 | 366 |
2013 | CUTTER EXPLORATION INC | Brine | 105 | 365 |
2014 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2015 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2016 | CUTTER EXPLORATION INC | Brine | 0 | 365 |
2017 | CUTTER EXPLORATION INC | Brine | 81 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1094898692 | 2010-9-4 0:00:0 | UD | No Violations | |
-1882905779 | 2010-9-5 0:00:0 | UD | No Violations | |
-1978580908 | 2018-11-2 0:00: | UP | No Violations | |
-2083078063 | 2016-5-12 0:00: | UP | No Violations | |
-391689665 | 2012-1-4 0:00:0 | UP | No Violations | |
-831195134 | 2010-10-8 0:00: | UD | No Violations | |
-833779958 | 2011-7-13 0:00: | PL | No Violations | |
0391689665 | 2012-01-04 | UrbanProduction Wells | No Violations | Well and battery are in good repair and all man doors are locked. An identification sign needs posted. |
0831195134 | 2010-10-08 | Urban Drill / Deepen / Reopen | No Violations | Operator was flowing well back. Site was in good repair. Lease road was stable. Pits were closed. Bull plugs were in frac Tanks. |
0833779958 | 2011-07-13 | Preliminary Restoration | No Violations | Well is a rabbit well, the catcher is red in color. Zero psi on the annulus. Locks on load lines. Identification is posted. Valve on dike drain. 2 100Bbl production tanks 1500 gallon poly tank and a mechincal separator are in the battery. Lease road is stable. Locks on man doors. Spacing is correct. |
1094898692 | 2010-09-04 | Urban Drill / Deepen / Reopen | No Violations | The conductor pipe was installed and cemented. All conditions were satisfactory. |
1286378280 | 2010-10-05 | Urban Drill / Deepen / Reopen | No Violations | Frac crew was moving off site. Frac job per the operator went well. Operator submitted Bond/cement log for the GCC#2. The 5 day annulus test result was 66psi. Lockport Top is 3114 top of the cement is 3050. Operator has 64 of coverage above the Lockport. |
1882905779 | 2010-09-05 | Urban Drill / Deepen / Reopen | No Violations | Surface casing was installed and cemented. Adequate cement returns were observed. Cement operation met all requirements. |
1973566843 | 2013-05-28 | UrbanProduction Wells | No Violations | My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open and plumbed into a pop off valve that is plumbed into the production tank. The tank battery and well are in good repair and surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL poly brine tank, and a mechanical separator. The vent stack on the production tank is plumbed into a 55 gallon charcoal filter. The vent stack is then plumbed up and topped with a spark arrestor. The proper identification is located on the tank battery. The lease road is in stable condition. |
1978580908 | 2018-11-02 | UrbanProduction Wells | No Violations | I conducted an inspection on this well. The well was equipped with a plunger lift assembly and in production at the time of this inspection. The well was fenced with a locked man door. The tank battery was comprised of two 100 BBL tanks, one 50 BBL tank and a mechanical separator. The tank battery was dked and fenced with a locked man door. Legible identification was located at the tank battery and the lease access was stable. |
2083078063 | 2016-05-12 | UrbanProduction Wells | No Violations | My inspection found the man doors on the tank battery fence and wellhead fence are secured with a chain and a lock. The company needs to install an identification sign. I have contacted Mr. Cutter about the issue. No other changes since my last inspection. |