X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-22121

Well Details

Well ID: 34-055-22121
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: GCC
License Status: Producing
License Date: 2010-03-23
Spud Date: 2010-09-04
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2010-09-10
Well Total Depth: 3804.00 ft
Configuration: Vertical
Latitude: 41.510000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-03-23 Proposed Formations:CLINTON, Issued Date:3/23/2010, Expired Date:3/23/2011 6:00:00 AM, Drilling unit acres:54.45, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-09-10
Completion Report Received 2010-10-21
Construction Permit Expires 2011-03-23
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-12-13 3624 3695 33
3624 3695 33
3624 3695 33

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-10-05 H2O 15 65000 Gal 45000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 CUTTER EXPLORATION INC 7200.00 167.00 366
2013 CUTTER EXPLORATION INC 8133.00 0.00 365
2014 CUTTER EXPLORATION INC 2526.00 81.00 365
2015 CUTTER EXPLORATION INC 1384.00 81.00 365
2016 CUTTER EXPLORATION INC 2604.00 0.00 365
2017 CUTTER EXPLORATION INC 0.00 1930.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 CUTTER EXPLORATION INC Brine 162 366
2013 CUTTER EXPLORATION INC Brine 105 365
2014 CUTTER EXPLORATION INC Brine 0 365
2015 CUTTER EXPLORATION INC Brine 0 365
2016 CUTTER EXPLORATION INC Brine 0 365
2017 CUTTER EXPLORATION INC Brine 81 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1094898692 2010-9-4 0:00:0 UD No Violations
-1882905779 2010-9-5 0:00:0 UD No Violations
-1978580908 2018-11-2 0:00: UP No Violations
-2083078063 2016-5-12 0:00: UP No Violations
-391689665 2012-1-4 0:00:0 UP No Violations
-831195134 2010-10-8 0:00: UD No Violations
-833779958 2011-7-13 0:00: PL No Violations
0391689665 2012-01-04 UrbanProduction Wells No Violations Well and battery are in good repair and all man doors are locked. An identification sign needs posted.
0831195134 2010-10-08 Urban Drill / Deepen / Reopen No Violations Operator was flowing well back. Site was in good repair. Lease road was stable. Pits were closed. Bull plugs were in frac Tanks.
0833779958 2011-07-13 Preliminary Restoration No Violations Well is a rabbit well, the catcher is red in color. Zero psi on the annulus. Locks on load lines. Identification is posted. Valve on dike drain. 2 100Bbl production tanks 1500 gallon poly tank and a mechincal separator are in the battery. Lease road is stable. Locks on man doors. Spacing is correct.
1094898692 2010-09-04 Urban Drill / Deepen / Reopen No Violations The conductor pipe was installed and cemented. All conditions were satisfactory.
1286378280 2010-10-05 Urban Drill / Deepen / Reopen No Violations Frac crew was moving off site. Frac job per the operator went well. Operator submitted Bond/cement log for the GCC#2. The 5 day annulus test result was 66psi. Lockport Top is 3114 top of the cement is 3050. Operator has 64 of coverage above the Lockport.
1882905779 2010-09-05 Urban Drill / Deepen / Reopen No Violations Surface casing was installed and cemented. Adequate cement returns were observed. Cement operation met all requirements.
1973566843 2013-05-28 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open and plumbed into a pop off valve that is plumbed into the production tank. The tank battery and well are in good repair and surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL poly brine tank, and a mechanical separator. The vent stack on the production tank is plumbed into a 55 gallon charcoal filter. The vent stack is then plumbed up and topped with a spark arrestor. The proper identification is located on the tank battery. The lease road is in stable condition.
1978580908 2018-11-02 UrbanProduction Wells No Violations I conducted an inspection on this well. The well was equipped with a plunger lift assembly and in production at the time of this inspection. The well was fenced with a locked man door. The tank battery was comprised of two 100 BBL tanks, one 50 BBL tank and a mechanical separator. The tank battery was dked and fenced with a locked man door. Legible identification was located at the tank battery and the lease access was stable.
2083078063 2016-05-12 UrbanProduction Wells No Violations My inspection found the man doors on the tank battery fence and wellhead fence are secured with a chain and a lock. The company needs to install an identification sign. I have contacted Mr. Cutter about the issue. No other changes since my last inspection.

For data sources see[9]

References