X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-22143

Well Details

Well ID: 34-055-22143
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Troy Township
Operator Name: EXCALIBUR EXPLORATION INC
Well Pad ID:
Farm/Lease Name: LARKS
License Status: Producing
License Date: 2014-06-30
Spud Date: 2014-08-23
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2014-08-27
Well Total Depth: 4260.00 ft
Configuration: Vertical
Latitude: 41.360000
Longitude: -81.150000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-06-21 Proposed Formations:ORISKANY/CLINTON, Issued Date:6/21/2012, Expired Date:6/21/2014 12:00:00 PM, Drilling unit acres:288.25, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2014-06-30 Proposed Formations:ORISKANY/CLINTON, Issued Date:6/30/2014, Expired Date:6/29/2016 12:00:00 PM, Drilling unit acres:288.25, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2014-08-27
Completion Report Received 2015-08-20
Construction Permit Expires 2016-06-29
Record Last Modified 2017-10-23

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 EXCALIBUR EXPLORATION INC 0.00 0.00 0
2015 EXCALIBUR EXPLORATION INC 5300.00 1273.00 334
2016 EXCALIBUR EXPLORATION INC 2484.00 822.00 365
2017 EXCALIBUR EXPLORATION INC 2193.00 284.00 365
2018 EXCALIBUR EXPLORATION INC 950.00 0.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 EXCALIBUR EXPLORATION INC Brine 325 0
2015 EXCALIBUR EXPLORATION INC Brine 1170 334
2016 EXCALIBUR EXPLORATION INC Brine 1635 365
2017 EXCALIBUR EXPLORATION INC Brine 1015 365
2018 EXCALIBUR EXPLORATION INC Brine 662 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1443902100 2018-9-24 0:00: PW No Violations
-665179937 2014-9-17 0:00: PL No Violations
-770365110 2014-8-25 0:00: DD No Violations
0099351821 2014-08-23 Casing String Witnessed No Violations I was on location for the cementing of the 8 5/8 surface casing. The hole was drilled to 400. The casing was set to 382. The landing joint was set to 362. Petroset was the cement company on location. Petroset broke circulation and ran 175 sacks of Class A cement that mudscaled at 15.6 ppg. The plug was released and displaced using 23 bbls of water. The plug landed and was pressured up on for five minutes. The amount of cement returns was 13 bbls. The location is in stable condition. The lease road is stoned back to where the tank battery will be located. The road from the end of the stone to the well site is approximately 200 and is in stable condition. The pits are stable and the liner is in good repair. The top soil is piled at the South side of the location. The cellar is constructed of a 46 plastic pipe. No violations found.
0665179937 2014-09-17 Preliminary Restoration No Violations My inspection found the well has a guage and pop off valve on the annulus. The guage reads zero psi. The pits are open and in stable condition. The pit liners are in good repair. There is four 500 BBL tanks on location for the company to hydraulic fracture the well on Friday. Hagans Well Service is setting up the service rig on location. The location is in stable condition. No violations found.
0770365110 2014-08-25 Drill / Deepen / Reopen No Violations My inspection found Poulson Drilling to have reached 2400. The company reported no issue while drilling the previous 2400. The site is in stable condition. The pit liners are in good repair. No violations found.
1103209312 2014-08-26 Drill / Deepen / Reopen No Violations My inspection today found Poulson Drilling to have reached 3492. The company has no issues to report while drilling the previous 3492. The location is in stable condition and the pits are in good repair. No violations found.
1358766347 2015-05-04 Preliminary Restoration No Violations My inspection found the well in production. There is still two piles of soil at the south end of the location. The tank battery is in good repair and the lease road is in stable condition. I spoke with Ron the excavator for Excalibur about spreading the soil and getting the soil seeded and strawed. He will complete the restoration within the next couple of weeks. Once vegetation is established preliminary restoration can be passed.
1408976060 2014-08-23 Drill / Deepen / Reopen No Violations I received a call from Roy Poulson from PDC Drilling that they had spudded the well at 8:30 AM on 8/23/2014.
1438187523 2015-07-29 Preliminary Restoration No Violations My inspection found the company has repaired a field drain tile that was damaged during excavation of the location. The clay pile and the top soil pile has been spread out on location. The company has to prep the soil, then seed and straw can be applied. Once vegetation is established preliminary restoration can be passed.
1443719932 2015-10-01 Preliminary Restoration No Violations My inspection found vegetation has been established on the location. The well is currently in production. The lease road is in stable condition. No violations found. Preliminary restoration can be passed.
1443902100 2018-09-24 Production Wells No Violations I conducted an inspection on this well. During this inspection, the well was equipped with a pumping unit and in production. The tank battery consisted of one 210 BBL tank, one 100 BBL tank and a mechanical separator. The tank battery was diked. Legible identification was located at the well and tank battery. The lease access was stable.
1532350322 2014-11-18 Production Wells No Violations My inspection found the well to be equpped with a pumpjack. The well is currently being produced. The tank battery has been completed and consists of a 210 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition. There is top soil piled on the West side of the location. In the spring the topsoil needs spread and vegetation needs established. Once that is complete preliminary restoration can be passed.
99351821 2014-8-23 0:00: CS No Violations

For data sources see[7]

References