If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-059-20324 | ![]() Sorry, we have no imagery here. Sorry, we have no imagery here. Sorry, we have no imagery here. ![]() |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Liberty Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: WALKER RAGAN D | |
License Status: Storage Well | |
License Date: | |
Spud Date: 1942-11-19 | |
Spud Drilling Contractor: | |
Final Drill Date: 1942-12-23 | |
Well Total Depth: 3286.00 ft | |
Configuration: Vertical | |
Latitude: 40.150000 | |
Longitude: -81.610000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1942-11-19 | 809.4 GL |
Completed | 1942-12-23 | 809.4 GL |
Reached Total Depth | 1942-12-23 | 809.4 GL |
Change of Owner | 2011-08-17 | Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION |
Record Last Modified | 2011-08-22 | 809.4 GL |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1593194859 | 2019-4-18 0:00: | SO | No Violations | 0.20 |
-1634603927 | 2016-10-19 0:00 | SO | No Violations | 0.50 |
-369550775 | 2019-8-15 0:00: | SO | No Violations | 0.50 |
-41614495 | 2016-4-12 0:00: | SO | No Violations | 5.50 |
-629124788 | 2018-10-31 0:00 | SO | No Violations | 0.10 |
-805765466 | 2016-4-13 0:00: | SO | No Violations | 1.00 |
-84464753 | 2019-8-15 0:00: | SO | No Violations | 0.70 |
0041614495 | 2016-04-12 | Storage Well | No Violations | On the day of my inspection I was on location for the topping off of the 7 inch surface casing. I witnessed that Hagan Well Service was on site and ran 1 inch tubing inside the 10 inch conductor pipe tagging up at 50 feet. C & J Services was on site and cemented the 7 inch surface casing with 200 sacks of Class A cement weighing 15.6ppg and a yield of 1.18cuft/sack. Cement weight was verified with pressurized mud scales and 5bbls of cement was circulated to surface. HWS will install a WDI 5000psi wellhead in preparation for upcoming re-frac of the well. |
0531668326 | 2017-10-05 | Storage Well | No Violations | On the day of my inspection I witnessed that the well was equipped with 7 inch diameter casing with valves in the open position and well identification was present with no violations. |
0629124788 | 2018-10-31 | Storage Well | No Violations | The purpose of my inspection was a status check on a natural gas storage well. During my inspection the well was equipped with 6.625-inch diameter casing with a flange casing head, a master valve, and a 3.5-inch diameter steel line leading to a drip tank. Identification was located at the wellhead. |
0782297584 | 2015-02-04 | Storage Well | No Violations | On the day of my inspection I witnessed that the well was equipped with 6.625 inch casing with valves in the open position and well identification was present with no violations. |
0805765466 | 2016-04-13 | Storage Well | No Violations | On the day of my inspection I witnessed the 5000psi wellhead was installed, pressured tested to 2000psi and the cement remained at the surface. Hagan Well Service will retrieve bridge plug tomorrow and turn well back over to Columbia Gas. |
1440075649 | 2015-08-20 | Storage Well | No Violations | There were no violations during the time of my inspection. Well was properly identified. |
1593194859 | 2019-04-18 | Storage Well | No Violations | The purpose of my inspection was a status check on a natural gas storage well. During my inspection the well was equipped with 6.625-inch diameter casing with a flange casing head, a master valve, and a 3.5-inch diameter steel line leading to a drip tank. Identification was legible and correct was located at the wellhead. |
1634603927 | 2016-10-19 | Storage Well | No Violations | On the day of my inspection I witnessed that the well was equipped with 7 inch casing with valves in the open position and well identification was present with no violations. |
2009306964 | 2016-01-28 | Storage Well | No Violations | My inspection today found this well to be in compliance, with no issues of concern. Required identification is attached to the well and the main valve is in the closed position. |
2063791760 | 2013-10-21 | Storage Well | No Violations | On the day of my inspection I witnessed that the valves were closed and the well identification was incorrect. Working with Columbia gas to correct the identification. |
2144915173 | 2020-4-2 0:00:0 | SO | No Violations | 0.50 |
531668326 | 2017-10-5 0:00: | SO | No Violations | 0.50 |
782297584 | 2015-2-4 0:00:0 | SO | No Violations | 0.50 |
For data sources see[3]