X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-21569

Well Details

Well ID: 34-059-21569
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Spencer Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: PALMER ROY E
License Status: Producing
License Date: 1972-05-03
Spud Date: 1972-05-02
Spud Drilling Contractor:
Final Drill Date: 1972-06-08
Well Total Depth: 5201.00 ft
Configuration: Vertical
Latitude: 39.860000
Longitude: -81.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1972-05-02
CO 1972-05-03 122 TIGER OIL INC GeoDate 5/3/72
Completed 1972-06-08
Reached Total Depth 1972-06-08
CO 1994-11-28 2680 ENERGY CONTRACTORS INC GeoDate 5/3/72
Change of Owner 1998-09-28 Operator changed from 2680, ENERGY CONTRACTORS INC to 952, G-R CONTRACTING INC
Change of Owner 2013-05-20 Operator changed from 952, G-R CONTRACTING INC to 1333, BIG SKY ENERGY INC
Change of Owner 2017-11-08 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2019-06-04

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5041 5095 23
5041 5095 23
5041 5095 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TIGER OIL INC 1205.00 154.00 0
1985 TIGER OIL INC 1317.00 216.00 365
1986 TIGER OIL INC 1046.00 80.00 365
1987 TIGER OIL INC 622.00 265.00 365
1989 TIGER OIL INC 0.00 462.00 365
1990 TIGER OIL INC 0.00 392.00 365
1991 TIGER OIL INC 0.00 0.00 365
1992 TIGER OIL INC 0.00 172.00 365
1993 TIGER OIL INC 0.00 105.00 180
1994 TIGER OIL INC 0.00 36.00 365
1995 ENERGY CONTRACTORS INC 0.00 0.00 365
1996 ENERGY CONTRACTORS INC 0.00 44.00 365
1997 ENERGY CONTRACTORS INC 493.00 118.00 365
1998 ENERGY CONTRACTORS INC 980.00 84.00 365
2001 G-R CONTRACTING INC 0.00 0.00 365
2002 G-R CONTRACTING INC 0.00 0.00 365
2003 G-R CONTRACTING INC 0.00 0.00 365
2004 G-R CONTRACTING INC 309.00 72.00 365
2005 G-R CONTRACTING INC 0.00 0.00 365
2006 G-R CONTRACTING INC 660.00 100.00 365
2007 G-R CONTRACTING INC 796.00 725.00 365
2008 G-R CONTRACTING INC 901.00 222.00 365
2009 G-R CONTRACTING INC 721.00 114.00 365
2010 G-R CONTRACTING INC 691.00 242.00 365
2011 G-R CONTRACTING INC 458.00 156.00 365
2012 G-R CONTRACTING INC 696.00 114.00 366
2013 G-R CONTRACTING INC 611.00 62.00 120
2014 G-R CONTRACTING INC 464.00 0.00 30
2016 BIG SKY ENERGY INC 185.00 0.00 98
2017 BIG SKY ENERGY INC 65.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TIGER OIL INC Brine 0 0
1985 TIGER OIL INC Brine 6 365
1986 TIGER OIL INC Brine 0 365
1987 TIGER OIL INC Brine 0 365
1989 TIGER OIL INC Brine 0 365
1990 TIGER OIL INC Brine 0 365
1991 TIGER OIL INC Brine 0 365
1992 TIGER OIL INC Brine 0 365
1993 TIGER OIL INC Brine 0 180
1994 TIGER OIL INC Brine 0 365
1995 ENERGY CONTRACTORS INC Brine 0 365
1996 ENERGY CONTRACTORS INC Brine 0 365
1997 ENERGY CONTRACTORS INC Brine 0 365
1998 ENERGY CONTRACTORS INC Brine 0 365
2001 G-R CONTRACTING INC Brine 0 365
2002 G-R CONTRACTING INC Brine 0 365
2003 G-R CONTRACTING INC Brine 0 365
2004 G-R CONTRACTING INC Brine 0 365
2005 G-R CONTRACTING INC Brine 0 365
2006 G-R CONTRACTING INC Brine 0 365
2007 G-R CONTRACTING INC Brine 0 365
2008 G-R CONTRACTING INC Brine 0 365
2009 G-R CONTRACTING INC Brine 0 365
2010 G-R CONTRACTING INC Brine 0 365
2011 G-R CONTRACTING INC Brine 0 365
2012 G-R CONTRACTING INC Brine 0 366
2013 G-R CONTRACTING INC Brine 0 120
2014 G-R CONTRACTING INC Brine 0 30
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1280765844 2020-1-2 0:00:0 PW No Violations 0.30
-1676058818 2005-9-2 0:00:0 PW No Violations
-1860309199 2017-11-20 0:00 PW No Violations 1.00
-202146985 2014-4-29 0:00: PW No Violations 1.50
-22655276 2006-3-13 0:00: PW No Violations
-659647899 2005-9-30 0:00: PW No Violations
-795194729 2014-3-27 0:00: PW No Violations 1.50
0022655276 2006-03-13 Production Wells No Violations STATUS CHECK
0202146985 2014-04-29 Production Wells No Violations

-43 and NOV-1727072826, I witnessed that the tank battery was shared with 34059215800000 Palmer 2, it consisted of 2- 210bbl tanks, a vertical separator, and a 2 inch meter run with a .375 inch orifice and chart recorder. Gas was flowing through the meter at the time of inspection with all valves open on the sales line. The well was capable of production and equipped with 4.5 inch casing, 2.375 inch tubing, rods and pumping unit powered electrically. One of two valves was open on the tubing and one of two valves was open on the casing. . Identification is present and production records are current through 2012. NOV-1727072826 is resolved.

0659647899 2005-09-30 Production Wells No Violations NO PRODUCTION SINCE 2001
0795194729 2014-03-27 Production Wells No Violations

-43 and NOV-1727072826, I witnessed that the tank battery was shared with 34059215800000 Palmer 2, it consisted of 2- 210bbl tanks, a vertical separator, and a 2 inch meter run with a .375 inch orifice and chart recorder. Gas was flowing through the meter at the time of inspection with all valves open on the sales line. The well was capable of production and equipped with 4.5 inch casing, 2.375 inch tubing, rods and pumping unit powered electrically. One of two valves was open on the tubing and one of two valves was open on the casing. Production records were current and identification has been corrected at the tank battery but remains incorrect at the wellhead. No dike has been constructed and contamination is still present around tanks and around wellhead.

1289i61512 2001-04-02 Production Wells No Violations well in production, no violations
1289i6151210 2001-4-2 0:00:0 PW No Violations
1400674129 2005-09-02 Production Wells No Violations STATUS CHECK
1609846116 2016-04-29 Production Wells No Violations

--105, I witnessed that production equipment included 2- 210bbl tanks with no dike present, a vertical separator, and a 2 inch meter run with a .375 inch orifice and chart recorder all shared with 34059215800000 Palmer 2. Light oil contamination was present near the 3 inch load line valve on the north 210bbl tank and near the burner flange on the south 210bbl tank. The well was equipped with 4.5 inch casing, 2.375 inch tubing, rod, a Jensen pumping unit powered by electricity with power in the off position and domestic gas service with the valves closed on the tubing and 1of 2 valves was open on the casing supplying the domestic gas. Identification was present and production records were current.

1676058818 2005-09-02 Production Wells No Violations STATUS CHECK.
1727072826 2014-02-26 Production Wells Violations Noted

-43, I witnessed that the tank battery was shared with 34059215800000 Palmer 2, it consisted of 2- 210bbl tank with no dike, a vertical separator, and a 2 inch meter run with a .375 inch orifice and chart recorder. Gas was flowing through the meter at the time of inspection with all valves open on the sales line. The well was capable of production and equipped with 4.5 inch casing, 2.375 inch tubing, rods and pumping unit powered electrically. One of two valves was open on the tubing and one of two valves was open on the casing. A 2 foot by 2 foot area around the well head was contaminated with oil. Production records were current and identification was present at the well and the tank battery however the company and phone numbers were incorrect. Company shall build an earthen dike with capacity sufficient to contain the two tanks, remove contamination around well head and replace with clean fill, seed and straw and the well shall be legibly identified.

1860309199 2017-11-20 Production Wells No Violations On the day of my inspection I witnessed that production equipment included 2- 210 barrel tanks with no dike present, a horizontal separator, and a 2 inch meter run with a .375 inch orifice and chart recorder all shared with 34059215800000 Palmer 2. The well was equipped with 4.5 inch diameter casing, 2.375 inch diameter tubing, rod, a Jensen pumping unit powered by electricity with power in the off position and domestic gas service with all the valves in the closed position. The well was transferred to Vortex Energy LLC on 11/8/17 with the identification in the process of being update and other identification present reflecting the prior owner of record. The production records were current for 2016.
2087157191 2016-04-18 Production Wells No Violations

--105, I witnessed that production equipment included 2- 210bbl tanks with no dike present, a vertical separator, and a 2 inch meter run with a .375 inch orifice and chart recorder all shared with 34059215800000 Palmer 2. Light oil contamination was present near the 3 inch load line valve on the north 210bbl tank and near the burner flange on the south 210bbl tank. The well was equipped with 4.5 inch casing, 2.375 inch tubing, rod, a Jensen pumping unit powered by electricity with power in the auto position and domestic gas line with 1 of 2 valves open on the tubing and 1of 2 valves was open on the casing supplying the domestic line. A disconnected Emsco pumping unit was also on site. Identification was present and production records were current.

996295043 2020-1-2 0:00:0 PW No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1727072826 US-OH-117142 2014-05-05 Well operation causing pollution and contamination
1727072826 US-OH-117143 2014-05-05 Failure to legibly identify well
1727072826 US-OH-117144 2014-05-05 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]

References