34-059-21703

Well Details

Well ID: 34-059-21703
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Brookfield Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: CLASS E
License Status: Producing
License Date: 1979-12-31
Spud Date: 1983-03-12
Spud Drilling Contractor:
Final Drill Date: 1983-03-17
Well Total Depth: 5056.00 ft
Configuration: Vertical
Latitude: 39.840000
Longitude: -81.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-12-31 122 TIGER OIL INC GeoDate 12/31/79
Original Spud 1983-03-12 R.I R.L. 1-16-80 DATES-COMMENCED & COMP. DATES IS CUT OFF!
Completed 1983-03-17 R.I R.L. 1-16-80 DATES-COMMENCED & COMP. DATES IS CUT OFF!
Reached Total Depth 1983-03-17 R.I R.L. 1-16-80 DATES-COMMENCED & COMP. DATES IS CUT OFF!
CO 1994-11-28 2680 ENERGY CONTRACTORS INC GeoDate 12/31/79
Change of Owner 1998-09-28 Operator changed from 2680, ENERGY CONTRACTORS INC to 952, G-R CONTRACTING INC
Change of Owner 2013-05-20 Operator changed from 952, G-R CONTRACTING INC to 1333, BIG SKY ENERGY INC
Change of Owner 2017-11-08 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2019-06-04 R.I R.L. 1-16-80 DATES-COMMENCED & COMP. DATES IS CUT OFF!

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4910 4970 15
4910 4970 15
4910 4970 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TIGER OIL INC 4309.00 377.00 0
1985 TIGER OIL INC 4513.00 383.00 365
1986 TIGER OIL INC 4473.00 295.00 365
1987 TIGER OIL INC 2453.00 335.00 365
1989 TIGER OIL INC 1970.00 94.00 365
1990 TIGER OIL INC 1748.00 188.00 365
1991 TIGER OIL INC 937.00 120.00 365
1992 TIGER OIL INC 1120.00 0.00 365
1993 TIGER OIL INC 1434.00 240.00 270
1994 TIGER OIL INC 1079.00 0.00 365
1995 ENERGY CONTRACTORS INC 396.00 41.00 365
1996 ENERGY CONTRACTORS INC 9.00 0.00 365
1997 ENERGY CONTRACTORS INC 674.00 61.00 365
1998 ENERGY CONTRACTORS INC 807.00 18.00 365
2001 G-R CONTRACTING INC 0.00 0.00 365
2002 G-R CONTRACTING INC 0.00 0.00 365
2003 G-R CONTRACTING INC 0.00 0.00 365
2004 G-R CONTRACTING INC 463.00 144.00 365
2005 G-R CONTRACTING INC 0.00 46.00 365
2006 G-R CONTRACTING INC 301.00 0.00 365
2007 G-R CONTRACTING INC 0.00 0.00 365
2008 G-R CONTRACTING INC 0.00 0.00 365
2009 G-R CONTRACTING INC 7.00 0.00 365
2010 G-R CONTRACTING INC 15.00 0.00 365
2011 G-R CONTRACTING INC 18.00 0.00 365
2012 G-R CONTRACTING INC 40.00 0.00 366
2013 G-R CONTRACTING INC 81.00 0.00 120
2014 BIG SKY ENERGY INC 665.00 0.00 365
2016 BIG SKY ENERGY INC 150.00 0.00 98
2017 BIG SKY ENERGY INC 23.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TIGER OIL INC Brine 0 0
1985 TIGER OIL INC Brine 90 365
1986 TIGER OIL INC Brine 0 365
1987 TIGER OIL INC Brine 0 365
1989 TIGER OIL INC Brine 0 365
1990 TIGER OIL INC Brine 0 365
1991 TIGER OIL INC Brine 0 365
1992 TIGER OIL INC Brine 0 365
1993 TIGER OIL INC Brine 40 270
1994 TIGER OIL INC Brine 120 365
1995 ENERGY CONTRACTORS INC Brine 0 365
1996 ENERGY CONTRACTORS INC Brine 0 365
1997 ENERGY CONTRACTORS INC Brine 0 365
1998 ENERGY CONTRACTORS INC Brine 0 365
2001 G-R CONTRACTING INC Brine 0 365
2002 G-R CONTRACTING INC Brine 0 365
2003 G-R CONTRACTING INC Brine 0 365
2004 G-R CONTRACTING INC Brine 0 365
2005 G-R CONTRACTING INC Brine 0 365
2006 G-R CONTRACTING INC Brine 0 365
2007 G-R CONTRACTING INC Brine 0 365
2008 G-R CONTRACTING INC Brine 0 365
2009 G-R CONTRACTING INC Brine 0 365
2010 G-R CONTRACTING INC Brine 0 365
2011 G-R CONTRACTING INC Brine 0 365
2012 G-R CONTRACTING INC Brine 0 366
2013 G-R CONTRACTING INC Brine 0 120
2014 G-R CONTRACTING INC Brine 0 30
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1234622471 2007-7-17 0:00: PW No Violations
-1880388780 2018-9-26 0:00: PW No Violations 0.50
-33029360 2019-4-10 0:00: PW No Violations
-568009997 2007-7-17 0:00: PW No Violations
-868661810 2014-3-25 0:00: PW No Violations
0033029360 2019-04-10 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with 4.5-inch diameter production casing with a tubing head, and 1.5-inch tubing. The production valves were in the open position. The production equipment consisted of one disconnected 210-barrel tank, one 100-barrel tank, one horizontal separator, and one small skid mounted compressor. The production records were current, and identification was located on the 100-barrel tank. Accompanied by ODNR inspector Rick Brown.
0421385520 2014-02-24 Production Wells Violations Noted On the day of my inspection I witnessed that there was a compressor unit running upon arrival and the tank battery consisted of a 210bbl tank disconnected from the flow line, a 100bbl tank, a horizontal separator, a drip and all valves were open on the flow line and sales line. The well was equipped with 4.5 inch casing, 2.875 inch tubing, 1.5 inch tubing open flowing to the separator, a pumping unit powered electrically was disconnected from the well and the rods and another string of tubing was on location, all the valves were in the open position at the well head. A 2 inch sales meter with a .25 inch orifice and a chart recorder was located west of the location with gas flowing through the meter. Production records were current and identification was present at the well and the tank battery however the company and phone numbers were incorrect. Company shall legibly identify well.
0507208290 2004-04-27 Production Wells Violations Noted WELL APPEARS TO BE IDLE; NO PRODUCTION RECORDS SINCE 1994.
0568009997 2007-07-17 Production Wells Violations Noted WELL IS IDLE APPEARS TO HAVE HOLE IN 4 CASING WATERED OUT. HAS NOT BEE PRODUCED FOR APPROXIMATELY 2 YRS.
0585864913 2008-05-27 Production Wells No Violations RESOLVED.
0868661810 2014-03-25 Production Wells No Violations

-43 and NOV-421385520, I witnessed that there was a compressor unit running upon arrival and the tank battery consisted of a 210bbl tank disconnected from the flow line, a 100bbl tank, a horizontal separator, a drip and all valves were open on the flow line and sales line. The well was equipped with 4.5 inch casing, 2.875 inch tubing, 1.5 inch tubing open flowing to the separator, a pumping unit powered electrically was disconnected from the well and the rods and another string of tubing was on location, all the valves were in the open position at the well head. A 2 inch sales meter with a .25 inch orifice and a chart recorder was located west of the location with gas flowing through the meter. Production records were current and identification was present at the well and the tank battery and has been corrected. Well remains in production.

0984551451 2007-08-14 Production Wells Violations Noted WELL APPEARS TO HAVE HOLE IN 4.5 CASING. BOTH CASINGS ARE DEAD. SURFACE EQUIPMENT HAS BEEN DISCONNECTED.
1015711960 2016-04-01 Production Wells No Violations

-105, I witnessed that production equipment included a 210bbl tank disconnected, a 100bbl tank and a horizontal separator with all valves were open on the flow line and sales line. A 2 foot by 6 foot area of oil contamination was present near the vertical section of the dump line on the 100bbl and the separator did not meet the spacing requirement of 10 feet from the tank. The well was equipped with 4.5 inch casing, 2.875 inch tubing, 1.5 inch tubing open flowing to the separator, a pumping unit powered electrically was disconnected from the well with the rods and another string of tubing was on location. The valves were in the closed position on the 1.5 inch tubing and 1 of 2 valves in the open position on the 2.875 inch tubing. A 2 inch sales meter with a .25 inch orifice and a chart recorder was located west of the location with gas flowing through the meter. Identification is present and production records were current.

1117627675 2005-05-31 Production Wells Violations Noted WELL APPEARS TO BE IDLE. NO PRODUCTION REPORTS FILED SINCE 2001. VALVES CLOSED.NOTHING ON CHART OR METER.
1128097878 2005-09-30 Production Wells No Violations NO PRODUCTION RECORDS SINCE 1986
1187112805 2007-08-14 Production Wells Violations Noted WELL IS IDLE. HOLE APPEARS TO BE IN 4.5 CASING. ALL SURFACE EQUIPMENT HAS BEEN DISCONNECTED.
1189209758 2016-04-18 Production Wells No Violations

--105, I witnessed that production equipment included a 210bbl tank disconnected, a 100bbl tank and a horizontal separator with all valves were open on the flow line and sales line. A 2 foot by 6 foot area of oil contamination was present near the vertical section of the dump line on the 100bbl and the separator did not meet the spacing requirement of 10 feet from the tank. The well was equipped with 4.5 inch casing, 2.875 inch tubing, 1.5 inch tubing open flowing to the separator, a pumping unit powered electrically was disconnected from the well with the rods and another string of tubing was on location. The valves were in the closed position on the 1.5 inch tubing and 1 of 2 valves in the open position on the 2.875 inch tubing. A 2 inch sales meter with a .25 inch orifice and a chart recorder was located west of the location with gas flowing through the meter. Identification is present and production records were current.

1194674276 2007-08-14 Production Wells Violations Noted FOLLOW UP TO NOV # 984551451 WELL APPEARS TO HAVE HOLE IN 4.5 CASING. BOTH CASINGS ARE DEAD. SURFACE EQUIPMENT HAS BEEN DISCONNECTED.
1234622471 2007-07-17 Production Wells Violations Noted FOLLOW UP TO NOV # -568009997 WELL IS IDLE APPEARS TO HAVE HOLE IN 4 CASING WATERED OUT. HAS NOT BEE PRODUCED FOR APPROXIMATELY 2 YRS.
1298025214 2014-04-28 Production Wells No Violations

-43, I witnessed that production equipment included a 210bbl tank disconnected, a 100bbl tank and a horizontal separator with all valves were open on the flow line and sales line. The well was equipped with 4.5 inch casing, 2.875 inch tubing, 1.5 inch tubing open flowing to the separator, a pumping unit powered electrically was disconnected from the well with the rods and another string of tubing was on location, all the valves were in the open position at the well head. A 2 inch sales meter with a .25 inch orifice and a chart recorder was located west of the location with gas flowing through the meter. Identification is present and production records are current through 2012.

1461067012 2016-04-19 Production Wells No Violations

--105, I witnessed that production equipment included a 210bbl tank disconnected, a 100bbl tank and a horizontal separator with all valves were open on the flow line and sales line. A 2 foot by 6 foot area of oil contamination was present near the vertical section of the dump line on the 100bbl and the separator did not meet the spacing requirement of 10 feet from the tank. The well was equipped with 4.5 inch casing, 2.875 inch tubing, 1.5 inch tubing open flowing to the separator, a pumping unit powered electrically was disconnected from the well with the rods and another string of tubing was on location. All valves were in the closed position. Identification is present and production records were current.

1473769455 2016-09-13 Production Wells No Violations

--105, I witnessed that production equipment included a disconnected 210 barrel tank, a 100 barrel tank, a horizontal separator and a compressor unit. The 2 feet by 6 feet area of oil contamination remains near the vertical section of the dump line. The 100 barrel tank and the separator do not meet the spacing requirement set forth in OAC 1501:9-9-05. The well was equipped with 4.5 inch casing, 2.875 inch tubing, 1.5 inch tubing and a pumping unit powered by electricity was disconnected from the well with the rods and another string of tubing was on location with all valves in the closed position. Identification is present and production records were current. The chart on the master meter has not been changed since 4/13/16 and there was no gas flowing through the meter.

1511184880 2017-11-20 Production Wells No Violations On the day of my inspection I witnessed that production equipment found in heavy vegetation included a disconnected 210 barrel tank, a 100 barrel tank, a horizontal separator and a compressor unit. The 100 barrel tank and the separator do not meet the spacing requirement set forth in OAC 1501:9-9-05. The well was equipped with 4.5 inch diameter, 2.875 inch diameter tubing, 1.5 inch diameter tubing and a pumping unit powered by electricity was disconnected from the well with all valves in the closed position. The chart on the Dominion master meter has not been changed since 4/13/16 and there was no gas flowing through the meter. The well was transferred to Vortex Energy LLC on 11/8/17 with the identification reflecting the prior owner of record. The production records were current for 2016.
1573520059 2012-05-15 Production Wells No Violations On the day of my inspection I found a pumping unit at the well site, the I.D. is posted on the pumping unit, there is a compressor/ separator/ (1) one hundred barrel production tank and (1) two hundred ten barrel production tank, the I.D. us posted on the production tank.
1698929289 2008-02-20 Production Wells No Violations WELL IS IN PRODUCTION. NOV RESOLVED.
1766348432 2005-09-02 Production Wells No Violations STATUS CHECK.
1767801531 2017-08-04 Production Wells No Violations

--105, I witnessed that production equipment found in heavy vegetation included a disconnected 210 barrel tank, a 100 barrel tank, a horizontal separator and a compressor unit. The 2 feet by 6 feet area of oil contamination remains near the vertical section of the dump line. The 100 barrel tank and the separator do not meet the spacing requirement set forth in OAC 1501:9-9-05. The well was equipped with 4.5 inch diameter, 2.875 inch diameter tubing, 1.5 inch diameter tubing and a pumping unit powered by electricity was disconnected from the well with the rods and another string of tubing was on location with all valves in the closed position. Identification is present and production records were not current. The chart on the Dominion master meter has not been changed since 4/13/16 and there was no gas flowing through the meter.

1880388780 2018-09-26 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with 4.5-inch diameter production casing with a tubing head, and 1.5-inch tubing. Production valves appeared to be in the closed position. A pumping unit without a horse head and a stack of sucker rods were located by the well. The production equipment consisted of one disconnected 210-barrel tank, one 100-barrel tank, one horizontal separator, and one small skid mounted compressor. The production records were current, and identification was located on the 100-barrel tank.
1918309399 2007-08-14 Production Wells Violations Noted FOLLOW UP TO NOV # 1187112805 WELL IS IDLE. HOLE APPEARS TO BE IN 4.5 CASING. ALL SURFACE EQUIPMENT HAS BEEN DISCONNECTED.
421385520 2014-2-24 0:00: PW No Violations 2.00
507208290 2004-4-27 0:00: PW No Violations
585864913 2008-5-27 0:00: PW No Violations
984551451 2007-8-14 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0421385520 US-OH-124488 2014-03-31 Failure to legibly identify well
0507208290 US-OH-125533 2004-04-27 Well shall be plugged
0568009997 US-OH-126389 2007-07-17 Well shall be plugged
0984551451 US-OH-131315 2007-08-14 Well shall be plugged
1117627675 US-OH-102968 2005-06-01 Well shall be plugged
1187112805 US-OH-104973 2007-08-14 Well shall be plugged
1194674276 US-OH-105128 2007-08-14 Well shall be plugged
1234622471 US-OH-106279 2007-07-17 Well shall be plugged
1918309399 US-OH-119277 2007-08-14 Well shall be plugged

For data sources see[9]

References