34-059-21716

Well Details

Well ID: 34-059-21716
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Cambridge Township
Operator Name: WHITED ROGER
Well Pad ID:
Farm/Lease Name: WELLMAN C
License Status: Producing
License Date:
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 40.040000
Longitude: -81.610000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1990-10-23 201 GREEN GAS CO
CO 1991-07-31 157 LANDPROVEST INC GeoDate
CO 1994-07-22 2172 NATLAND ENERGY CORP GeoDate
CO 1996-01-12 5352 ARTEX OIL COMPANY GeoDate
Change of Owner 2015-08-25 Operator changed from 5352, ARTEX OIL COMPANY to 7382, WHITED ROGER
Record Last Modified 2019-06-04 LOCATION INFO ADDED FROM 96 PROD TOWNSHIP ADDED CAMBRIDGE SECTION ADDED 6 LOT ADDED

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1991 LANDPROVEST INC 696.00 0.00 365
1992 LANDPROVEST INC 1198.00 0.00 366
1993 LANDPROVEST INC 561.00 0.00 304
1994 NATLAND ENERGY CORP 1126.00 0.00 365
1995 ARTEX OIL COMPANY 859.00 0.00 365
1996 ARTEX OIL COMPANY 824.00 0.00 365
1997 ARTEX OIL COMPANY 908.00 0.00 365
1998 ARTEX OIL COMPANY 696.00 0.00 0
1999 ARTEX OIL COMPANY 870.00 0.00 0
2000 ARTEX OIL COMPANY 3661.00 131.00 365
2001 ARTEX OIL COMPANY 2460.00 0.00 365
2002 ARTEX OIL COMPANY 1975.00 0.00 365
2003 ARTEX OIL COMPANY 1260.00 0.00 365
2004 ARTEX OIL COMPANY 2179.00 0.00 365
2005 ARTEX OIL COMPANY 2120.00 0.00 365
2006 ARTEX OIL COMPANY 1811.00 0.00 365
2007 ARTEX OIL COMPANY 791.00 0.00 365
2008 ARTEX OIL COMPANY 414.00 0.00 365
2009 ARTEX OIL COMPANY 538.00 0.00 365
2010 ARTEX OIL COMPANY 612.00 0.00 365
2011 ARTEX OIL COMPANY 597.00 0.00 365
2012 ARTEX OIL COMPANY 617.00 0.00 366
2013 ARTEX OIL COMPANY 1085.00 0.00 365
2014 ARTEX OIL COMPANY 1181.00 0.00 365
2015 ARTEX OIL COMPANY 963.00 0.00 365
2016 WHITED ROGER 706.00 0.00 244
2017 WHITED ROGER 303.00 0.00 365
2018 WHITED ROGER 248.00 0.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1991 LANDPROVEST INC Brine 0 365
1992 LANDPROVEST INC Brine 0 366
1993 LANDPROVEST INC Brine 0 304
1994 NATLAND ENERGY CORP Brine 0 365
1995 ARTEX OIL COMPANY Brine 0 365
1996 ARTEX OIL COMPANY Brine 0 365
1997 ARTEX OIL COMPANY Brine 0 365
1998 ARTEX OIL COMPANY Brine
1999 ARTEX OIL COMPANY Brine 70
2000 ARTEX OIL COMPANY Brine 70 365
2001 ARTEX OIL COMPANY Brine 0 365
2002 ARTEX OIL COMPANY Brine 0 365
2003 ARTEX OIL COMPANY Brine 0 365
2004 ARTEX OIL COMPANY Brine 0 365
2005 ARTEX OIL COMPANY Brine 0 365
2006 ARTEX OIL COMPANY Brine 0 365
2007 ARTEX OIL COMPANY Brine 0 365
2008 ARTEX OIL COMPANY Brine 0 365
2009 ARTEX OIL COMPANY Brine 62 365
2010 ARTEX OIL COMPANY Brine 0 365
2011 ARTEX OIL COMPANY Brine 0 365
2012 ARTEX OIL COMPANY Brine 0 366
2013 ARTEX OIL COMPANY Brine 71 365
2014 ARTEX OIL COMPANY Brine 0 365
2015 ARTEX OIL COMPANY Brine 56 365
2016 WHITED ROGER Brine 0 244
2017 WHITED ROGER Brine 0 365
2018 WHITED ROGER Brine 0 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1024420346 2008-2-29 0:00: PW No Violations
-1052366241 2006-4-10 0:00: PW No Violations
-1297854619 2018-3-26 0:00: PW No Violations 0.80
-1322776851 2018-10-25 0:00 PW No Violations 0.20
-1457514948 2020-6-2 0:00:0 PW No Violations 1.00
-1549769817 2018-3-26 0:00: PW No Violations 0.80
-15880117 2006-6-8 0:00:0 PW No Violations
-1697061644 2017-11-27 0:00 PW No Violations 1.00
-1944008330 2005-12-13 0:00 PW No Violations
0015880117 2006-06-08 Production Wells No Violations PRODUCING WELL
0204802170 2018-01-02 Production Wells No Violations On the day of my inspection following up on Compliance Notice 1697061644, I witnessed there was no change in the status of the well since the inspection on 11/27/17. The well was equipped with 4.5 inch diameter casing, 2.375 inch diameter tubing, rods, an Emsco pumping unit powered by electricity and domestic gas service with 1 of 2 valves open on the casing supplying the domestic gas. Also present plumbed from the tubing, a 225 gallon plastic tank with 185 gallons of produced fluids in it near the wellhead with no dike. Contamination was found in a 5 feet radius around the wellhead and near the drain valve on the plastic tank. No identification was present and production records were current. I placed call to Patchwork Oil and Gas and spoke to Jessica Lott who stated they never received the notice but she did have a non-receipt of a certified letter from the Division. I stated what needed done to bring the well into compliance.
0249179754 2008-03-04 Production Wells No Violations LOAD LINE VALVE REPLACED SINCE LAST INSPECTION
1024420346 2008-02-29 Production Wells No Violations PRODUCING WELL
1052366241 2006-04-10 Production Wells No Violations STATUS CHECK. PRODUCING WELL.
1297854619 2018-03-26 Production Wells No Violations On the day of my inspection accompanied by ODNR Inspector Jeff Adams and following up on Compliance Notice 1697061644, I witnessed there was no change in the status of the well since the inspection on 2/7/18. The well was equipped with 4.5 inch diameter casing, 2.375 inch diameter tubing, rods, an Emsco pumping unit powered by electricity and domestic gas service with 1 of 2 valves open on the casing supplying the domestic gas. Also present plumbed from the tubing, a 225 gallon plastic tank with 185 gallons of produced fluids in it near the wellhead with no dike. Contamination remains in a 5 feet radius around the wellhead and near the drain valve on the plastic tank. No identification was present and production records were current.
1322776851 2018-10-25 Production Wells No Violations The purpose of my inspection was to follow up on Compliance Notice numbered 1697061644. The compliance notice stated that the tank was in violation of spacing requirements. During my inspection today, the tank remained within the maximum allowable distance from the wellhead.
1527779509 2018-05-31 Production Wells No Violations At 7:19 p.m. 5/30/18 Columbia Gas called and stated that they were at a residence at 65045 Pigeon Gap Road Cambridge Ohio and they have located multiple leaks in a gas line coming from a well. During my inspection on 5/31/18 I found 5 spots that appear to be leaking within a natural gas domestic gas line that was traveling from the house to the well owned by Patchwork Oil and Gas. I spoke with Roger Whited the owner of Patchwork Oil and Gas and Mr. Whited stated he would have someone out to shut the domestic gas service off to allow time for the line to be repaired. A Patchwork representative arrived and shut the valve off on the 4.5 inch diameter production casing that was supplying the domestic gas. The lines were no longer leaking. All valves at the wellhead were in the closed position. While discussing the issue with Roger Whited I brought up the fact that the well remains in violation of 1501:9-1-07(A)10, 1501:9-9-05(A)2, and 1501:9-9-05(A)9. The violations were written in the compliance notice 1697061644 that was issued to Roger Whited. Mr. Whited stated that he would be out as soon as he found the time to correct the violations.
1530894892 2018-07-05 Production Wells No Violations The purpose of my inspection was to follow up on Compliance Notice numbered 1697061644. The compliance notice was issued to Roger Whited for violation of tank spacing requirements. During my inspection today, the tank remained within the maximum allowable distance from the wellhead. I will continue to contact Roger Whited and work with him to correct the violation.
1546678744 2018-02-07 Production Wells No Violations On the day of my inspection following up on Compliance Notice 1697061644 with the ground snow covered, I witnessed there was no change in the status of the well since the inspection on 1/2/18. The well was equipped with 4.5 inch diameter casing, 2.375 inch diameter tubing, rods, an Emsco pumping unit powered by electricity and domestic gas service with 1 of 2 valves open on the casing supplying the domestic gas. Also present plumbed from the tubing, a 225 gallon plastic tank with 185 gallons of produced fluids in it near the wellhead with no dike. Contamination was found in a 5 feet radius around the wellhead and near the drain valve on the plastic tank. No identification was present and production records were current. I received a call from Roger Whited on 1/10/18 stating that he would address the issues.
1549769817 2018-03-26 Production Wells No Violations On the day of inspection I accompanied ODNR Inspector Doug Bennett. See his report for details.
1697061644 2017-11-27 Production Wells Violations Noted On the day of my inspection I witnessed the well was equipped with 4.5 inch diameter casing, 2.375 inch diameter tubing, rods, an Emsco pumping unit powered by electricity and domestic gas service with 1 of 2 valves open on the casing supplying the domestic gas. Also present plumbed from the tubing, a 225 gallon plastic tank with 185 gallons of produced fluids in it near the wellhead with no dike. Contamination was found in a 5 feet radius around the wellhead and near the drain valve on the plastic tank. No identification was present and production records were current. Owner/Operator shall properly identify well in accordance with OAC 1501:9-9-05 (A) (10). Owner/Operator shall meet proper setback distance from the well to the 225 gallon tank on location in accordance with OAC 1501:9-9-05 (A) (2). Owner/Operator shall remediate affected areas by removing soils, replacing with clean fill and disposing of properly.
1944008330 2005-12-13 Production Wells No Violations STATUS CHECK
1986787432 2019-01-18 Production Wells No Violations The purpose of my inspection was to follow up on Compliance Notice numbered 1697061644. During my inspection the well was equipped with 4.5-inch diameter production casing, 2.375-inch diameter tubing, rods, a pumping unit. Production valves were in the open position. A domestic gas line was attached to the production casing with an open valve. The contamination at the wellhead that resulted in compliance notice 1697061644 has now been remediated resolving the notice. While burying a new domestic gas line up to the 4.5-inch diameter production casing the contamination was remediated. The production equipment was located on the opposite side of Pigeon Gap road and consisted of one 210-barrel tank, one compressor, and one chart meter with current chart. The identification was located on the 210-barrel tank.
204802170 2018-1-2 0:00:0 PW No Violations 1.00
249179754 2008-3-4 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1697061644 US-OH-116824 2017-12-07 Well operation causing pollution and contamination
1697061644 US-OH-116825 2017-12-07 Failure to legibly identify well
1697061644 US-OH-116826 2017-12-07 Violation of tank spacing requirements
1697061644 US-OH-116827 2017-12-07 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[7]