If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-059-21800 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.88,"lon":-81.63,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Spencer Township | |
Operator Name: VORTEX ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: LESTOCK-HOWELL ETAL UNIT | |
License Status: Producing | |
License Date: 1974-04-19 | |
Spud Date: 1974-07-29 | |
Spud Drilling Contractor: | |
Final Drill Date: 1974-08-08 | |
Well Total Depth: 5147.00 ft | |
Configuration: Vertical | |
Latitude: 39.880000 | |
Longitude: -81.630000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1974-04-19 | 182 BELDEN & BLAKE CO GeoDate 4/19/74 |
Original Spud | 1974-07-29 | CS |
Completed | 1974-08-08 | CS |
Reached Total Depth | 1974-08-08 | CS |
CO | 1993-01-28 | 4381 PELICAN PRODUCING INC GeoDate 4/19/74 |
CO | 1995-11-24 | 1217 HARRISON ENERGY GeoDate 4/19/74 |
CO | 1996-04-10 | 952 G-R CONTRACTING INC GeoDate 4/19/74 |
Change of Owner | 2013-05-20 | Operator changed from 952, G-R CONTRACTING INC to 1333, BIG SKY ENERGY INC |
Change of Owner | 2017-11-08 | Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC |
Record Last Modified | 2019-06-04 | CS |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4965 | 4995 | 2 |
4965 | 4995 | 2 | |
4965 | 4995 | 2 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 91000 Gal | 50000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | ENTERPRISE ENERGY CORP | 0.00 | 215.00 | 0 |
1985 | OXFORD OIL | 0.00 | 432.00 | 365 |
1986 | OXFORD OIL | 0.00 | 372.00 | 365 |
1987 | BELDEN & BLAKE CORPORATION | 0.00 | 207.00 | 365 |
1988 | BELDEN & BLAKE CORPORATION | 0.00 | 428.00 | 220 |
1990 | BELDEN & BLAKE CORPORATION | 417.00 | 454.00 | 153 |
1991 | BELDEN & BLAKE CORPORATION | 1375.00 | 254.00 | 365 |
1992 | BELDEN & BLAKE CORPORATION | 695.00 | 102.00 | 238 |
1993 | BELDEN & BLAKE CORPORATION | 29.00 | 0.00 | 366 |
1994 | PELICAN PRODUCING INC | 762.00 | 257.00 | 365 |
1995 | PELICAN PRODUCING INC | 520.00 | 379.00 | 310 |
1996 | G-R CONTRACTING INC | 713.00 | 203.00 | 365 |
1997 | G-R CONTRACTING INC | 691.00 | 214.00 | 365 |
1998 | G-R CONTRACTING INC | 598.00 | 96.00 | 365 |
2000 | G-R CONTRACTING INC | 421.00 | 298.00 | 365 |
2001 | G-R CONTRACTING INC | 516.00 | 215.00 | 365 |
2002 | G-R CONTRACTING INC | 418.00 | 0.00 | 365 |
2003 | G-R CONTRACTING INC | 379.00 | 0.00 | 365 |
2004 | G-R CONTRACTING INC | 329.00 | 210.00 | 365 |
2005 | G-R CONTRACTING INC | 344.00 | 266.00 | 365 |
2006 | G-R CONTRACTING INC | 744.00 | 214.00 | 365 |
2007 | G-R CONTRACTING INC | 301.00 | 216.00 | 365 |
2008 | G-R CONTRACTING INC | 380.00 | 254.00 | 365 |
2009 | G-R CONTRACTING INC | 325.00 | 118.00 | 365 |
2010 | G-R CONTRACTING INC | 369.00 | 126.00 | 365 |
2011 | G-R CONTRACTING INC | 351.00 | 115.00 | 365 |
2012 | G-R CONTRACTING INC | 316.00 | 0.00 | 366 |
2013 | G-R CONTRACTING INC | 329.00 | 179.00 | 120 |
2014 | BIG SKY ENERGY INC | 0.00 | 0.00 | 365 |
2016 | BIG SKY ENERGY INC | 160.00 | 0.00 | 98 |
2017 | BIG SKY ENERGY INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | ENTERPRISE ENERGY CORP | Brine | 140 | 0 |
1985 | OXFORD OIL | Brine | 0 | 365 |
1986 | OXFORD OIL | Brine | 0 | 365 |
1987 | BELDEN & BLAKE CORPORATION | Brine | 16 | 365 |
1988 | BELDEN & BLAKE CORPORATION | Brine | 30 | 220 |
1990 | BELDEN & BLAKE CORPORATION | Brine | 41 | 153 |
1991 | BELDEN & BLAKE CORPORATION | Brine | 22 | 365 |
1992 | BELDEN & BLAKE CORPORATION | Brine | 27 | 238 |
1993 | BELDEN & BLAKE CORPORATION | Brine | 0 | 366 |
1994 | PELICAN PRODUCING INC | Brine | 14 | 365 |
1995 | PELICAN PRODUCING INC | Brine | 0 | 310 |
1996 | G-R CONTRACTING INC | Brine | 0 | 365 |
1997 | G-R CONTRACTING INC | Brine | 0 | 365 |
1998 | G-R CONTRACTING INC | Brine | 0 | 365 |
2000 | G-R CONTRACTING INC | Brine | 0 | 365 |
2001 | G-R CONTRACTING INC | Brine | 0 | 365 |
2002 | G-R CONTRACTING INC | Brine | 0 | 365 |
2003 | G-R CONTRACTING INC | Brine | 0 | 365 |
2004 | G-R CONTRACTING INC | Brine | 0 | 365 |
2005 | G-R CONTRACTING INC | Brine | 0 | 365 |
2006 | G-R CONTRACTING INC | Brine | 0 | 365 |
2007 | G-R CONTRACTING INC | Brine | 0 | 365 |
2008 | G-R CONTRACTING INC | Brine | 0 | 365 |
2009 | G-R CONTRACTING INC | Brine | 0 | 365 |
2010 | G-R CONTRACTING INC | Brine | 0 | 365 |
2011 | G-R CONTRACTING INC | Brine | 0 | 365 |
2012 | G-R CONTRACTING INC | Brine | 0 | 366 |
2013 | G-R CONTRACTING INC | Brine | 0 | 120 |
2014 | G-R CONTRACTING INC | Brine | 0 | 30 |
2016 | BIG SKY ENERGY INC | Brine | 0 | 98 |
2017 | BIG SKY ENERGY INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1391818253 | 2015-8-25 0:00: | PW | No Violations | 1.00 |
-1937727169 | 2004-1-13 0:00: | PW | No Violations | |
-2011663957 | 2016-5-1 0:00:0 | PW | No Violations | 0.50 |
-42578910 | 2005-6-2 0:00:0 | PW | No Violations | |
0042578910 | 2005-06-02 | Production Wells | No Violations | STATUS CHECK. WELL IS PRODUCING. |
0471557394 | 2006-06-27 | Production Wells | No Violations | PRODUCTION WELLS. |
1305932444 | 2016-04-14 | Production Wells | No Violations
--105, I witnessed the production equipment included a 210bbl tank, a horizontal separator, a 2 inch sales meter with .125 inch orifice and a chart recorder and a current chart. The well was equipped with 8.625 inch casing, 4.5 inch casing, 2.375 inch tubing, rods and a Lufkin pumping unit powered by natural gas with 1 of 2 valves open on the tubing and all valves open on the casing. Identification was present and production records were current. | |
1391818253 | 2015-08-25 | Production Wells | No Violations | On the day of my inspection following up on Complaint ID #5100, I witnessed the production equipment included a 210bbl tank, a horizontal separator, a 2 inch sales meter with .125 inch orifice and a chart recorder and a current chart all within an earthen dike. High vegetation was present around the production equipment with no contamination found. The well was equipped with 8.625 inch casing, 4.5 inch casing, 2.375 inch tubing, rods and a Lufkin pumping unit powered by natural gas with 1 of 2 valves open on the tubing and all valves open on the casing. Identification was present and production records were current. No contamination was found at the wellhead. I located a salesline drip and 5bbl polymer tank located along the access road with no contamination present. The tank was 80% full so I placed call to Big Sky well tender Greg Henderson and instructed him to pump out the tank. |
1539216195 | 2013-02-28 | Production Wells | No Violations | On the day of my inspection I reviewed the Divisions production records and found them to be current, there is four inch production casing with two inch tubing and a pumping unit, the valves are open on the well, there is (2) separators, (2) drips/ chart/(4) two hundred ten barrel production tanks with I.D. posted, the chart record is current as of this date. |
1695224679 | 2006-11-24 | Production Wells | No Violations | PRODUCING WELL |
1781509192 | 2016-05-17 | Production Wells | No Violations | The purpose of my inspection today is a Civil Action Follow---10 5. As of 5/17/16 domestic gas has been shut off. During my inspection I witnessed Greg Henderson from Big Sky shut in the domestic gas line. All valves on the well are now in the closed position. Greg Henderson and I went to all homes that were receiving natural gas from this well to inform them that they will be without natural gas. |
1937727169 | 2004-01-13 | Production Wells | No Violations | STATUS CHECK |
2011663957 | 2016-05-01 | Production Wells | No Violations
--105, I witnessed the production equipment included a 210bbl tank, a horizontal separator with domestic gas service, a 2 inch sales meter with .125 inch orifice and a chart recorder and a current chart. The well was equipped with 8.625 inch casing, 4.5 inch casing, 2.375 inch tubing, rods and a Lufkin pumping unit powered by natural gas with 1 of 2 valves open on the tubing and all valves open on the casing supplying the domestic gas service on the separator. Identification was present and production records were current. | |
471557394 | 2006-6-27 0:00: | PW | No Violations |
For data sources see[9]