X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-22525

Well Details

Well ID: 34-059-22525
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Buffalo Township
Operator Name: STONEBRIDGE OPERATING CO LLC
Well Pad ID:
Farm/Lease Name: SINGLETON
License Status: Final Restoration
License Date: 2017-04-25
Spud Date: 1979-08-28
Spud Drilling Contractor: MID ATLANTC DRLG
Final Drill Date: 1979-09-02
Well Total Depth: 5791.00 ft
Configuration: Vertical
Latitude: 39.890000
Longitude: -81.470000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-05-31 2098 OPI INC GeoDate 5/31/79
Original Spud 1979-08-28 R.I. 6-6-79 S/OIL=I.P.
Completed 1979-09-02 R.I. 6-6-79 S/OIL=I.P.
Reached Total Depth 1979-09-02 R.I. 6-6-79 S/OIL=I.P.
Completion Report Received 1979-11-10 R.I. 6-6-79 S/OIL=I.P.
CO 1994-06-28 631 BT ENERGY CORP GeoDate 5/31/79
Change of Owner 2007-10-12 Operator changed from 631, BT ENERGY CORP to 2070, STONEBRIDGE OPERATING CO
APP 2017-04-25 Proposed Formations:DEVONIAN SHALE, Issued Date:4/25/2017, Expired Date:4/25/2019 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2018-10-18 R.I. 6-6-79 S/OIL=I.P.
Construction Permit Expires 2019-04-25 R.I. 6-6-79 S/OIL=I.P.
Record Last Modified 2019-05-10 R.I. 6-6-79 S/OIL=I.P.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5592 5634 22
5592 5634 22
5592 5634 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BT ENERGY CORP 222.00 382.00 365
1985 BT ENERGY CORP 9.00 598.00 365
1986 BT ENERGY CORP 9.00 598.00 365
1987 BT ENERGY CORP 0.00 396.00 365
1988 BT ENERGY CORP 0.00 356.00 365
1990 BT ENERGY CORP 0.00 0.00 0
1991 BT ENERGY CORP 366.00 0.00 365
1993 BT ENERGY CORP 0.00 198.00 365
1994 BT ENERGY CORP 0.00 59.00 365
1995 BT ENERGY CORP 0.00 75.00 0
1996 BT ENERGY CORP 0.00 0.00 28
1997 BT ENERGY CORP 0.00 0.00 28
1998 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2000 STONEBRIDGE OPERATING CO LLC 0.00 52.00 366
2001 STONEBRIDGE OPERATING CO LLC 0.00 61.00 100
2002 BT ENERGY CORP 0.00 34.00 0
2003 BT ENERGY CORP 0.00 35.00 7
2004 BT ENERGY CORP 0.00 41.00 357
2005 BT ENERGY CORP 0.00 0.00 357
2006 BT ENERGY CORP 0.00 0.00 245
2007 STONEBRIDGE OPERATING CO LLC 0.00 0.00 364
2008 STONEBRIDGE OPERATING CO LLC 0.00 0.00 365
2009 STONEBRIDGE OPERATING CO LLC 0.00 50.00 0
2010 STONEBRIDGE OPERATING CO LLC 18.00 14.00 365
2011 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2012 STONEBRIDGE OPERATING CO LLC 0.00 0.00 364
2013 STONEBRIDGE OPERATING CO LLC 0.00 0.00 365
2014 STONEBRIDGE OPERATING CO LLC 0.00 0.00 42
2015 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2016 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2017 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2018 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BT ENERGY CORP Brine 0 365
1985 BT ENERGY CORP Brine 431 365
1986 BT ENERGY CORP Brine 334 365
1987 BT ENERGY CORP Brine 0 365
1988 BT ENERGY CORP Brine 0 365
1990 BT ENERGY CORP Brine 0 0
1991 BT ENERGY CORP Brine 0 365
1993 BT ENERGY CORP Brine 51 365
1994 BT ENERGY CORP Brine 0 365
1995 BT ENERGY CORP Brine 0 0
1996 BT ENERGY CORP Brine 0 28
1997 BT ENERGY CORP Brine 0 28
1998 STONEBRIDGE OPERATING CO LLC Brine 0 0
2000 STONEBRIDGE OPERATING CO LLC Brine 0 366
2001 STONEBRIDGE OPERATING CO LLC Brine 75 100
2002 BT ENERGY CORP Brine 0 0
2003 BT ENERGY CORP Brine 0 7
2004 BT ENERGY CORP Brine 0 357
2005 BT ENERGY CORP Brine 0 357
2006 BT ENERGY CORP Brine 0 245
2007 STONEBRIDGE OPERATING CO LLC Brine 0 364
2008 STONEBRIDGE OPERATING CO LLC Brine 11 365
2009 STONEBRIDGE OPERATING CO LLC Brine 0 0
2010 STONEBRIDGE OPERATING CO LLC Brine 0 365
2011 STONEBRIDGE OPERATING CO LLC Brine 0
2012 STONEBRIDGE OPERATING CO LLC Brine 0 364
2013 STONEBRIDGE OPERATING CO LLC Brine 0 365
2014 STONEBRIDGE OPERATING CO LLC Brine 0 42
2015 STONEBRIDGE OPERATING CO LLC Brine 0 0
2016 STONEBRIDGE OPERATING CO LLC Brine 0 0
2017 STONEBRIDGE OPERATING CO LLC Brine 0 0
2018 STONEBRIDGE OPERATING CO LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1049623076 2017-7-6 0:00:0 PW No Violations 1.00
-1240725708 2015-6-9 0:00:0 PW No Violations 1.00
-1408666173 2018-10-17 0:00 PB No Violations 3.00
-1575446845 2016-12-8 0:00: PW No Violations 1.00
-1623792312 2018-10-18 0:00 PB No Violations 8.00
-1745254758 2008-8-7 0:00:0 PW No Violations
-303365890 2017-10-6 0:00: PW No Violations 0.80
-564532972 2017-12-19 0:00 PW No Violations 0.80
-754733010 2016-4-27 0:00: PW No Violations 1.00
-830050945 2014-2-18 0:00: PW No Violations 1.50
0163529324 2014-04-10 Production Wells No Violations On the day of my inspection following up on Chiefs order #2014-39 and NOV-1361464389, I reviewed The Division of Oil and Gas production records and found them not current for the years of 2012 and 2013. The well appeared to be capable of production, there is an electrically powered pumping unit at the well site, the switch on the power box appeared to be in the off position, the valves were closed on the tubing and were closed on the production casing, the I.D. was present at the well and has been corrected on the separator.
0303365890 2017-10-06 Production Wells No Violations On the day of my inspection following up on Compliance Notice-1631464389, I witnessed that there was no change in the status of the well since last inspection on July 6, 2017. The production equipment included a 100 barrel tank, horizontal separator, drip, a 2 inch salesmeter with a .125 inch orifice and the chart present is the same chart from the February 18, 2014 inspection. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 1.5 inch diameter tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the wellhead. The lease road continues to show signs of erosion. Identification was present and production records were current with zero production reported since 2011. A plug back permit was issued for the well on April 25, 2017 with Stonebridge proposing to have the well plugged back and producing if warranted by December 31, 2018. If plug back is not warranted the well will be plugged by December 31, 2018 and reclaimed according to ORC 1509.072B.
0511112935 2014-03-13 Production Wells No Violations

-39 and NOV-1631464389, I witnessed that the tank battery consisted of a 100bbl tank, horizontal separator, drip, a 2 inch sales meter with a .125 inch orifice, chart was present showing no gas flowing through meter and the valves were open on the sales line to a compressor unit which was not operating. The well was capable of production and equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, rods, an electrically powered pumping unit, power was in the off position, the valves were closed on the tubing and 1 of 2 valves was closed on the casing at the well head. Identification was present at the well and has been corrected on the separator.

0563447768 2016-07-18 Production Wells No Violations On the day of my inspection following up on Compliance Notice-1631464389, I witnessed that there was no change in the status of the well since last inspection on April 27, 2016. The production equipment included a 100 barrel tank, horizontal separator, drip, a 2 inch sales meter with a .125 inch orifice, chart present is the same chart from the February 18, 2014 inspection. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the well head. The lease road has eroded to the point where it is impassible. Identification was present and production records were current with zero production reported in 2015.
0564532972 2017-12-19 Production Wells No Violations On the day of my inspection following up on Compliance Notice-1631464389, I witnessed that there was no change in the status of the well since last inspection on October 6, 2017. The production equipment included a 100 barrel tank, horizontal separator, drip, a 2 inch salesmeter with a .125 inch orifice and the chart present is the same chart from the February 18, 2014 inspection. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 1.5 inch diameter tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the wellhead. The lease road continues to show signs of erosion. Identification was present and production records were current with zero production reported since 2011. A plug back permit was issued for the well on April 25, 2017 with Stonebridge proposing to have the well plugged back and producing if warranted by December 31, 2018. If plug back is not warranted the well will be plugged by December 31, 2018 and reclaimed according to ORC 1509.072B.
0754733010 2016-04-27 Production Wells No Violations On the day of my inspection following up on NOV-1631464389, I witnessed that there was no change in the status of the well since last inspection on March 8, 2016. The production equipment included a in tank, horizontal separator, drip, a 2 inch sales meter with a .125 inch orifice, chart present is the same chart from February 18, 2014 inspection. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the well head. The lease road has eroded to the point where it is impassible. Identification was present and production records were current with zero production reported in 2015.
0830050945 2014-02-18 Production Wells Violations Noted
1049623076 2017-07-06 Production Wells No Violations On the day of my inspection following up on Compliance Notice-1631464389, I witnessed that there was no change in the status of the well since last inspection on March 27, 2017. The production equipment included a 100 barrel tank, horizontal separator, drip, a 2 inch salesmeter with a .125 inch orifice and the chart present is the same chart from the February 18, 2014 inspection. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 1.5 inch diameter tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the wellhead. The lease road continues to show signs of erosion. Identification was present and production records were current with zero production reported since 2011. A plug back permit was issued for the well on April 25, 2017 with Stonebridge proposing to have the well plugged back and producing if warranted by December 31, 2018. If plug back is not warranted the well will be plugged by December 31, 2018 and reclaimed according to ORC 1509.072B.
1062639455 2014-05-22 Production Wells No Violations

-39 and NOV-1631464389, I witnessed that the tank battery consisted of a 100bbl tank, horizontal separator, drip, a 2 inch sales meter with a .125 inch orifice, chart was present showing no gas flowing through meter and the valves were open on the sales line to a compressor unit which was not operating. The well was capable of production and equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, rods, an electrically powered pumping unit, power was in the off position, the valves were closed on the tubing and 1 of 2 valves was closed on the casing at the well head. Identification was present at the well and on the separator.

1075044014 2015-12-02 Production Wells No Violations On the day of my inspection following up on NOV-1631464389 accompanied by ODNR Inspector Joe Zollars, I witnessed that there was no change in the status of the well. The production equipment included a in tank, horizontal separator, drip, a 2 inch sales meter with a .125 inch orifice, chart present is the same chart from February 18, 2014 inspection. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the well head. The lease road has eroded to the point where it is impassible. Identification was present at the well and on the separator.
1218194463 2008-08-08 Production Wells Violations Noted DUANE LARSON PHONE CALL TO RESIDENCE. COMPLAINING OF COMPANY COMING IN AND TEARING UP YARD AND GARDEN LOOKING FOR GAS LINE TO SAID WELL.INVESTIGATION REVEALED WELL HAS NOT BEEN PRODUCED SINCE 2004. WELL IS IDLE PUMPING UNIT OFF WELL ALL VALVES ARE CLOSED.
1240725708 2015-06-09 Production Wells No Violations On the day of my inspection following up on NOV-1631464389, I witnessed that there was no change in the status of the well. The production equipment included a 100bbl tank, horizontal separator, drip, a 2 inch sales meter with a .125 inch orifice, chart was present showing no gas flowing through meter and the valves were open on the sales line to a compressor unit which was not operating. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the well head. The lease road has eroded to the point where it is impassible. Identification was present at the well and on the separator.
1255988894 2009-10-19 Production Wells Violations Noted Inspection revealed that well is still idle,no production reported on well since 2004,well is equipped with pumping unit and tubing and rods and 2-100 bbl tanks that are in violation of spacing requirements and seperator.
1264243078 2010-01-21 Production Wells No Violations Inspection revealed that there has been no change in status of proper tank spacing at site, called company rep and left message for him to call back (still awaiting call back from company rep.)will go to company office and discuss current violations at site.
1327619836 2018-03-12 Production Wells No Violations On the day of my inspection following up on Compliance Notice-1631464389, I witnessed that there was no change in the status of the well since last inspection on December, 2017. The production equipment included a 100 barrel tank, horizontal separator, drip, a 2 inch salesmeter with a .125 inch orifice and the chart present is the same chart from the February 18, 2014 inspection. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 1.5 inch diameter tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the wellhead. The lease road continues to show signs of erosion. Identification was present and production records were current with zero production reported since 2011. A plug back permit was issued for the well on April 25, 2017 with Stonebridge proposing to have the well plugged back and producing if warranted by December 31, 2018. If plug back is not warranted the well will be plugged by December 31, 2018 and reclaimed according to ORC 1509.072B.
1408666173 2018-10-17 Plug / Plug Back No Violations The purpose of my inspection today was to follow up on compliance notice numbered -1631464389. The well will be plugged to resolve the compliance notice. Cemenco pumped a 400-foot Clinton plug with 30 sacks of Class A cement from 5592 feet to 5192 feet through the 4.5-inch diameter production casing. After the plug was pumped and displaced with 83 barrels of water the 4.5-inch diameter casing valve was shut in for the night.
1427302708 2015-03-25 Production Wells No Violations

-39 and NOV-1631464389, I witnessed that the tank battery consisted of a 100bbl tank, horizontal separator, drip, a 2 inch sales meter with a .125 inch orifice, chart was present showing no gas flowing through meter and the valves were open on the sales line to a compressor unit which was not operating. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the well head. The lease road has eroded to the point where it is impassible. Identification was present at the well and on the separator.

1546003348 2018-12-27 Final Restoration No Violations The purpose of my inspection was a status check on a final restoration. I witnessed plugging operations on 10/18/2018. During my inspection today, all production equipment and debris have been removed. The lease road and wellsite have been seeded and mulched. Thin vegetation had taken place. Once the vegetation becomes thicker to proved soil stability the location will meet the requirements for final restoration.
1575446845 2016-12-08 Production Wells No Violations On the day of my inspection accompanied by ODNR Southeast Regional Manager Brent Bear following up on Compliance Notice-1631464389, I witnessed that there was no change in the status of the well since last inspection on September 12, 2016. The production equipment included a in tank, horizontal separator, drip, a 2 inch sales meter with a .125 inch orifice, chart present is the same chart from February 18, 2014 inspection. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the well head. The lease road continues to show signs of erosion. Identification was present and production records were current with zero production reported in 2011, 2012, 2013, 2014 and 2015. During a meeting at the 34059220440000 Shriver 1 with Stonebridge Field Supervisor John Schneider, Mr. Schneider stated that he would draft a plan to address the status of the well and submit the plan to ODNR within two weeks.
1623792312 2018-10-18 Plug / Plug Back No Violations Berry Well Service tripped the 4.5-inch ripping tools within the 4.5-inch casing and telegraph was achieved at 3445 feet casing was ripped at 3445 feet. Cemenco pumped a 300-foot 90 sack class A cement Big Lime plug from 3385 feet to 3085 feet within the 7.875 inch borehole. The 4.5-inch casing was pulled up to 1625 feet and Cemenco pumped a 60 sack plug 100 feet out and 100 feet in the bottom of the 8.625-inch diameter surface casing which sets at 1525 feet. The 4.5-inch diameter casing was tripped out of hole and Cemenco Pumped a Class A cement plug from 120 feet to surface. Accompanied by ODNR Regional Supervisor Brent Bear. The well was plugged to resolve compliance notice -1631464389.
163529324 2014-4-10 0:00: PW No Violations
1745254758 2008-08-07 Production Wells No Violations DUANE LARSON, 260-3836. WELL IS IDLE SINCE 04. SUDDENLY A CREW UNKNOWN TO HIM APPEARS ON HIS PROPERTY AND DESTROYS HIS TOTAL GARDEN DIGGING UP THE GAS LINE. HE WAS TOLD BY THESE PEOPLE THEY ARE OUT OF WEST VIRGINIA AND THEY ARE THINKING OF TAKING THIS WELL OVER FROM STONEBRIDGF CORP. N.O.V WILL BE ISSUED TO STONEBRIDGE FOR IDLE WELL.
1851435012 2018-06-05 Production Wells No Violations The purpose of my inspection today was to follow up on compliance notice numbered -1631464389. During my inspection the well was equipped with 8.625 inch diameter casing with a casing head, 4.5 inch diameter casing with a tubing head, 1.5 inch diameter tubing, rods, and a pumping unit. The production line attached to the tubing had a valve in the closed position. The line attached to the 4.5 inch casing had a valve in the closed position. The production equipment consisted of one 100 barrel tank, one horizontal separator, one drip, and a sales meter. The Sales meter had a 2 inch diameter sales line, a .125 inch orifice plate, and the chart recorder. Production records have been submitted by Stonebridge Operating Company reporting zero production for the consecutive years 2011 through 2017. Pictures were taken to assist this inspection.
1929150918 2015-07-06 Production Wells No Violations On the day of my inspection following up on NOV-1631464389, I witnessed that there was no change in the status of the well. The production equipment included a 100bbl tank, horizontal separator, drip, a 2 inch sales meter with a .125 inch orifice, chart present is the same chart from February 18, 2014 inspection. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the well head. The lease road has eroded to the point where it is impassible. Identification was present at the well and on the separator.
2070117235 2017-03-27 Production Wells No Violations On the day of my inspection following up on Compliance Notice-1631464389, I witnessed that there was no change in the status of the well since last inspection on February 2, 2017. The production equipment included a 100 barrel tank, horizontal separator, drip, a 2 inch salesmeter with a .125 inch orifice and the chart present is the same chart from the February 18, 2014 inspection. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 1.5 inch diameter tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the wellhead. The lease road continues to show signs of erosion. Identification was present and production records were current with zero production reported since 2011. No proposal from Stonebridge has been received for resolving the Compliance Notice.
2125610398 2017-02-02 Production Wells No Violations On the day of my inspection following up on Compliance Notice-1631464389, I witnessed that there was no change in the status of the well since last inspection on December 8, 2016. The production equipment included a 100 barrel tank, horizontal separator, drip, a 2 inch salesmeter with a .125 inch orifice and the chart present is the same chart from the February 18, 2014 inspection. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 1.5 inch diameter tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the wellhead. The lease road continues to show signs of erosion. Identification was present and production records were current with zero production reported since 2011. No proposal from Stonebridge has been received for resolving the Compliance Notice.
2138293064 2016-03-08 Production Wells No Violations On the day of my inspection following up on NOV-1631464389, I witnessed that there was no change in the status of the well since last inspection on December 2, 2015. The production equipment included a in tank, horizontal separator, drip, a 2 inch sales meter with a .125 inch orifice, chart present is the same chart from February 18, 2014 inspection. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, rods, an electrically powered pumping unit with the power in the off position, the valves were closed on the tubing and 1 of 2 valves was open on the casing at the well head. The lease road has eroded to the point where it is impassible. Identification was present at the well and on the separator.
37560965 2019-11-26 0:00 FR No Violations 0.30
511112935 2014-3-13 0:00: PW No Violations 1.50
563447768 2016-7-18 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0830050945 US-OH-129464 2014-04-10 Well shall be plugged
1218194463 US-OH-105849 2009-10-19 Violation of tank spacing requirements
1218194463 US-OH-105850 2008-08-08 Well shall be plugged
1255988894 US-OH-106898 2009-10-19 Violation of tank spacing requirements
1255988894 US-OH-106899 2008-08-08 Well shall be plugged

For data sources see[9]

References